Page 19
Installation
Attaching the AC/DC Power Pack and Powering On 1. Insert the small plug on the end of the AC/DC power pack cord into the power port. 2. Plug the AC/DC power pack into an electrical outlet. (120 VAC or 90-264 VAC as appropriate) 3. Power on the Aironet Access Point by pushing the On/Off button.
On/Off Button
When power is initially applied to the Aironet Access Point, all three indicators will flash in sequence to test the functionality of the indicators.
2-5
Page 20
Installation
Viewing the Indicator Displays Top Panel Indicators The indicators are a set of displays located on the top panel of the Aironet Access Point unit. •
• •
Ethernet Indicator - Used to indicate Ethernet network traffic activity. The light is normally off, but will flash green whenever a packet is received or transmitted over the Ethernet interface. Status Indicator - Shows solid green when the Aironet Access Point has accepted a radio association. Radio Indicator - Used to indicate radio traffic activity. The light is normally off, but will flash green whenever a packet is received or transmitted over the radio.
When the Aironet Access Point is initially powered up, all three displays will flash amber, red and then green, in sequence. If a power-on test fails, the status indicator will go solid red and the unit will stop functioning. See Table 1.1 for a detailed explanation of the Top Panel indicators.
Ethernet Status Radio
2-6
Page 21
Installation
Table 2.1 – Top Panel Indicator Description Type Nonassociated Station
Indicator Display Ethernet Status Radio Blinking Green Green
Green
Blinking Green
Operational Blinking Green
Green
Green
Error/Warning
Blinking Amber
Blinking Amber
Green Blinking Amber
Failure Firmware Upgrade
Red
Red Red
2-7
Red
Description No nodes associated One or more nodes associated Transmitting/ Receiving Radio packets Transmitting/ Receiving Ethernet packets Maximum retries/buffer full occurred on radio Transmit/ Receive errors General warning, check the logs Software failure Flashing the firmware
Page 22
Installation
Back Panel Indicators The back panel indicators are: • • • • • •
10BaseT polarity: Solid amber to indicate the 10BaseT polarity is reversed. Check cable connections. 10BaseT active: Solid green to indicate the 10BaseT has been configured as the active port. Ethernet Rx: Flashes green when an Ethernet packet has been received. Ethernet Tx: Flashes green when an Ethernet packet has been transmitted. 10Base2 active: Solid green to indicate the 10Base2 has been configured as the active port. Packet Collision: Flashes amber to indicate a packet collision has occurred.
10BaseT polarity Packet Collision
Ethernet Tx
Ethernet Rx 10Base2 active
2-8
10BaseT active
Page 23
Configuration
Configuration This section describes the methods used to access and configure the Console system of the Aironet Access Point. This system contains all commands necessary to initially configure and monitor the operation of the unit.
Accessing the Console System There are many ways in which you may configure and monitor the Aironet Access Point. When the unit is first powered up, basic configuration must initially be performed by accessing the Console serial port. To gain access through the serial port, the Aironet Access Point must be connected to a terminal or a PC running a terminal emulation program. Set the terminal to 9600 Baud, No-Parity, 8 data bits, 1 stop bit, and ANSI compatible. The Console system is organized as a set of menus. Each selection in a menu list may either take you to a sub-menu or display a command that will configure or display information controlling the unit. Once the Aironet Access Point has been assigned an IP address, you may then access the Console remotely using: • • •
Telnet protocol from a remote host or PC HTML browser, such as Netscape Navigator from a remote host Simple Network Management Protocol (SNMP) from a remote network management station
3-1
Page 24
Configuration
Configuring the Access Point To configure the Aironet Access Point so it will communicate with other stations or repeaters, use the Console Port to set the SSID parameter. If you choose to set an IP address, remote access via telnet or an HTML browser will be possible. SSID Identifier (ESSID) The SSID is a unique identifier that is attached to selected packets sent out over the radio network. This functions as a password to join the radio network. Stations associating to the Aironet Access Point must use the same identifier in their configurations, or their association requests will be ignored. To define an SSID: 1. Select Configuration from the Main Menu. 2. Select Radio from the Configuration Menu. 3. Select ESSID. 4. Enter a value for the SSID option. You may use up to 32 characters. All devices in the same radio network must use the same SSID.
3-2
Page 25
Configuration
Assigning an IP Address An IP address must be assigned to the unit before it can be accessed by telnet, HTTP, or SNMP. Other detailed internet addressing options (such as gateway address, SNMP routing, etc.) can also be defined. Refer to the Technical Reference Manual document #710-004021 for further details. To assign an IP address: 1. Select Configuration from the Main Menu. 2. Select Ident from the Configuration Menu. 3. Use the INADDR option to establish an IP address. 4. Use the INMASK option to define the internet mask, as appropriate. Verifying Association Once you have configured the Aironet Access Point and station devices with the correct parameters, the Radio Indicator will flash green indicating RF data traffic. The Status Indicator will be solid green indicating one or more stations have associated to the Aironet Access Point.
3-3
Page 26
Technical Support
Technical Support Technical Reference Manual Use the Technical Reference Manual document #710-004021 to learn more about your Aironet unit.
Communications Use the following information to contact the Aironet Technical Support group: Telephone - (330) 664-7903 Fax (330) 664-7990 e-mail techsupp@aironet.com
Web Site For additional product information and technical support, including the capability to download new firmware and drivers, use the Aironet web site at: http://www.aironet.com
4-1
Page 27
Technical Support
4-2