Appendix II LINEAR IMAGER (CCD), LASER (SE950) The tables below list reader settings as well as symbology settings for the Linear Imager (CCD) or Laser (SE950) scan engine.
READER SETTINGS TABLE CCD/Laser Engine
Description
Time-out 1~9 (second)
Default 3 sec.
Set the maximum time for decoding to continue during a scan attempt. It applies to the following scan modes only –
Laser mode Auto Off mode Scan Mode Continuous Mode
Laser mode Non-stop scanning
To decode the same barcode repeatedly, move away the scan beam and target it at the barcode for each scanning.
Test Mode
Non-stop scanning
Capable of decoding the same barcode repeatedly Alternate Mode
Press the scan trigger to start with scanning.
The scanning won't stop until you press the trigger again. Laser Mode
Hold down the scan trigger to start with scanning.
The scanning won't stop until (a) a barcode is read, (b) the preset timeout expires, or (c) you release the trigger.
Auto Off Mode
Press the scan trigger to start with scanning.
The scanning won't stop until (a) a barcode is read or (b) the preset timeout expires.
Redundancy Level None
None No redundancy means one successful decoding will make the reading valid and induce the "READER Event".
One time, Two times, The higher the reading security is (that is, the more redundancy the user or Three times selects), the slower the reading speed gets.
If "Three Times" is selected, it will take a total of four consecutive successful decodings of the same barcode to make the reading valid.
121
Page 134
9400 Mobile Computer Reference Manual
SYMBOLOGY SETTINGS TABLE CCD/Laser Engine
Description
Codabar
Default Enable
Select Start/Stop Characters
If "Transmit Start/Stop Characters" is desired, select one abcd / abcd set:
abcd / abcd abcd / tn*e ABCD / ABCD ABCD / TN*E Transmit Start/Stop Characters
Decide whether to include the start/stop characters in the No data being transmitted.
Code 128
Enable
GS1-128 (EAN-128)
Enable
Transmit Code ID Replace Separator
Decide whether to include Code ID (“]C1”) will be included No in the data being transmitted. Field Decide whether to replace the field separator. If the No barcode contains Field Separator “0x1D”, it will be changed to the desired Field Separator. For example, type the desired character “;” (semicolon) as the new field separator. Then if the barcode contains Field Separator “0x1D”, it will be changed to “;”.
ISBT 128
Enable
Industrial 25 (Discrete 25)
Enable
Start/Stop Selection
This decides the readability of all 2 of 5 symbology Industrial 25 variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25".
Verify Check Digit
Decide whether to verify the check digit. If the check digit No is incorrect, the barcode will not be accepted.
Transmit Check Digit
Decide whether to include the check digit in the data being Yes transmitted.
Select Length
One or two fixed lengths Range
Interleaved 25
4~127 Enable
Start/Stop Selection
Refer to Industrial 25.
Verify Check Digit
Decide whether to verify the check digit. If the check digit No is incorrect, the barcode will not be accepted.
Transmit Check Digit
Decide whether to include the check digit in the data being Yes transmitted.
122
Interleaved 25
Page 135
Appendix II Linear Imager (CCD), Laser (SE950) Select Length
One or two fixed lengths Range
Matrix 25
4~127 Enable
Start/Stop Selection
Refer to Industrial 25.
Verify Check Digit
Decide whether to verify the check digit. If the check digit No is incorrect, the barcode will not be accepted.
Transmit Check Digit
Decide whether to include the check digit in the data being Yes transmitted.
Select Length
One or two fixed lengths Range
French Pharmacode Transmit Check Digit
4~127 Disable
Decide whether to include the check digit in the data being Yes transmitted.
Italian Pharmacode (Code 32) Transmit Check Digit
Matrix 25
Disable
Decide whether to include the check digit in the data being Yes transmitted.
Note: For French/Italian Pharmacode, “Transmit Start/Stop Character” is not provided in UI but it is controlled by the same setting of Code 39. Code 39
Enable
Transmit Start/Stop Character
Decide whether to include the start/stop characters "*" in No the data being transmitted.
Verify Check Digit
Decide whether to verify the check digit. If the check digit No is incorrect, the barcode will not be accepted.
Transmit Check Digit
Decide whether to include the check digit in the data being Yes transmitted.
Code 39 Full ASCII
Code 39 Full ASCII includes all the alphanumeric and Disable special characters.
Code 93
Enable
MSI
Disable
Verify Check Digit
Select one of the three calculation formulas to verify the Single Modulo check digit. If the check digit is incorrect, the barcode will 10 not be accepted.
Single Modulo 10 Double Modulo 10 Modulo 11 & 10 Transmit Check Digit
Decide whether to include the check digit in the data being Both digits transmitted. transmitted
Last digit not transmitted Both digits transmitted Both digits not transmitted
123
Page 136
9400 Mobile Computer Reference Manual Select Length
One or two fixed lengths Range
4~127
Negative Barcode
Disable
Plessey
Disable
Convert to UK Plessey
When applied, each occurrence of the character "A" in the No barcode data will be replaced by the character "X".
Transmit Check Digit
Decide whether to include the two check digits in the data Yes being transmitted.
Telepen
Disable
Original Telepen (Numeric)
The original Telepen includes numeric characters.
AIM Telepen (Full ASCII)
AIM Telepen (Full ASCII) includes all the alphanumeric and No special characters.
GS1 DataBar-14 (RSS-14)
Yes
Disable
GS1 DataBar-14 is short for GS1 DataBar Omnidirectional. This group consists of (1) GS1 DataBar Omnidirectional, (2) GS1 DataBar Truncated, (3) GS1 DataBar Stacked, and (4) GS1 DataBar Stacked Omnidirectional. Transmit Code ID
Decide whether to include Code ID (“]e0”) will be included Yes in the data being transmitted.
Transmit Application ID
Decide whether to include the Application ID ("01") in the Yes data being transmitted.
Transmit Check Digit
Decide whether to include the check digit in the data being Yes transmitted.
GS1 DataBar Limited (RSS Limited)
Disable
Transmit Code ID
Refer to RSS-14.
Yes
Transmit Application ID
Refer to RSS-14.
Yes
Transmit Check Digit
Refer to RSS-14.
Yes
GS1 DataBar Expanded (RSS Expanded)
Disable
This group consists of (1) GS1 DataBar Expanded, and (2) GS1 DataBar Expanded Stacked. Transmit Code ID
Refer to RSS-14.
EAN-8
Yes Enable
Convert to EAN-13
The EAN-8 barcode will be expanded into EAN-13, and the No next processing will follow the settings configured for EAN-13.
Transmit Check Digit
Decide whether to include the check digit in the data being Yes transmitted.
Addon 2 / Addon 5
Decide whether to decode EAN-8 with addons.
EAN-13 / UPC-A
No Enable
ISBN Conversion
The EAN-13 barcode starting with 978 and 979 will be No converted to ISBN.
ISSN Conversion
The EAN-13 barcode starting with 977 will be converted to No ISSN.
124
Page 137
Appendix II Linear Imager (CCD), Laser (SE950) GTIN for EAN-13
The EAN-13 barcode will be expanded into 14-digit Global No Trade Item Number (GTIN).
Transmit Check Digit
Decide whether to include the check digit in the data being Yes transmitted.
Addon 2 / Addon 5
Decide whether to decode EAN-13/UPC-A with addons.
(UPC-A) Convert to EAN-13
The UPC-A barcode will be expanded into EAN-13, and the Yes next processing will follow the settings configured for EAN-13.
(UPC-A) Transmit Check Digit
Decide whether to include the UPC-A check digit in the Yes data being transmitted.
(UPC-A) Transmit System Number
Decide whether to include the UPC-A System Number in Yes the data being transmitted.
UPC-E
No
Enable
UPC-E0 / UPC-E1
Decide whether to decode the UPC-E0 barcodes only or UPC-E0 only both UPC-E0 and UPC-E1 barcodes.
Convert to UPC-A
The UPC-E barcode will be expanded into UPC-A, and the No next processing will follow the settings configured for UPC-A.
Transmit Check Digit
Decide whether to include the UPC-E check digit in the Yes data being transmitted.
Transmit System Number
Decide whether to include the UPC-E System Number in No the data being transmitted.
Addon 2 / Addon 5
Decide whether to decode UPC-E with addons.
No
Note: UPC-E1 is supported with decoder version 1.02 or later.
125
Page 138
9400 Mobile Computer Reference Manual
126