The text of a manual · part 14 of 20
9400 Mobile Computer Reference Manual (Windows CE Mobile Computer 9400): USING READER CONFIGURATION UTILITY
Pages 101 to 106 of 151, from 9400 Mobile Computer Reference Manual (Windows CE Mobile Computer 9400)
The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the CipherLab 9401, CipherLab 9471 and CipherLab 9491
Page 101
Chapter 7 USING READER CONFIGURATION UTILITY Reader Configuration Utility is the tool that lets you manage the barcode and RFID readers integrated on the mobile computer. Note: Before executing ImageMaker.exe.
the utility, make sure you have closed the program
IN THIS CHAPTER 7.1 Run 94ReaderConfig.exe............................................. 90 7.2 Barcode Reader Settings............................................. 91 7.3 RFID Reader Settings ................................................. 91 7.4 Data Output .............................................................. 93 7.5 Notifications (for Good Read)....................................... 94 7.6 Symbology Settings ................................................... 94
89
Page 102
9400 Mobile Computer Reference Manual
7.1 RUN 94READERCONFIG.EXE 1) Go to Start | Programs | 94ReaderConfig to open the Reader Configuration Utility. The associated icon will appear on the taskbar.
2) Tap the icon to access the menu that allows you to choose and enable one or both of the readers. There will be a check mark in front of the reader if it is enabled. If the RFID Reader is installed, the option will be available.
3) To meet your application requirements, proceed to configure associated reader settings as well as barcode settings. Note: (1) The 94ReaderConfig.exe utility will automatically detect the reader module(s) that is currently installed in the mobile computer. (2) If you wish to reload the default settings, delete the ReaderCfgINI.txt file in DiskOnChip before launching the program, or tap [Restore Defaults] on the General tab after launching the program.
90
Page 103
Chapter 7 Using Reader Configuration Utility
7.2 BARCODE READER SETTINGS The barcode reader configurations depend on the scan engine(s) installed. You can tell which reader is currently in use and make necessary changes on the General tab. Barcode Reader
Description
CCD/Laser Reader
If installed, tap the [Barcode Reader] button to configure the reader settings for CCD or Laser scan engine.
Refer to the Reader Settings Table in Appendix II - Linear Imager (CCD), Laser (SE950).
2D Reader
The 2D scan engine is capable of reading linear and 2D barcodes. If installed, tap the [Barcode Reader] button to configure the reader settings for 2D scan engine.
Refer to the Reader Settings Table in Appendix III - 2D Imager. 7.3 RFID READER SETTINGS If the RFID scan engine is present, configurable options will be displayed. Note: Because it is possible to read barcode and RFID tag at the same time, it is recommended that only one scan engine is enabled at a time to prevent from misreading. Some RFID tags support both read/write operations, on a page-by-page basis. You may find it necessary to define your own read/write operation. For reference only, the table below lists the start page for read/write operation on a number of RFID tags. Start Page
Tag Type
Standard
-1
Start from byte 0 of the default page (see below) for all tags
4
Mifare
ISO 14443A
4
SR176
ISO 14443B
3
ICODE SLI
ISO 15693
0
LRI512
ISO 15693
3
SRF55VxxP
ISO 15693
0
EM4135
ISO 15693
0
Tag-it HF-I
ISO 15693
0
Others
ISO 15693
5
ICODE
ICODE® (Phillips)
0
Tag-it
Tag-it® (TI)
Note: Please refer to the specifications of your RFID tags for memory organization.
91
Page 104
9400 Mobile Computer Reference Manual
7.3.1 READ OPERATION Read Settings By default, the RFID tag is read from byte 0 of the default page. However, the default page, amount of bytes and number of pages of each tag may be different. Specify how many bytes of data you want to read from the tag. Generally, the read data is user data obtained from the user block. If you are sure that the data is to be read from a non-user block, such as the lock block, you need to select the check box of [Display hex values] first.
7.3.2 WRITE OPERATION Write Settings Type the string that you want to write to a tag. By default, the string is written to the tag from byte 0 of the default page. However, the default page, amount of bytes and number of pages of each tag may be different. Therefore, the input string will automatically be truncated to fit into pages, and data may be discarded when it comes to the end of pages available. Generally, it will write the input string to the user block, which is free for custom use. The string will be displayed as “user data”. If you wish to write the string to a non-user block, such as the lock block, you need to select the check box of [Use hex values] first. Once you have selected to use hex values for the string, the string length must be even. For example, if you want to write 0x0A, 0x0B and 0x00 to a tag, the string you input must be “0A0B00” instead of “AB0”.
92
Page 105
Chapter 7 Using Reader Configuration Utility
7.4 DATA OUTPUT Tap the [Data Output] button on the General tab to choose from the three options for data output after decoding as well as configure associated settings. Default
Data Output Keyboard Emulation
Data is emulated as typed text and sent to the active Window.
Local machine
When
“Local machine” is selected, simply run your application or built-in program, such as WordPad, to start with data collection.
When “RDP server” is selected, run the Remote Desktop Connection program to connect to a remote computer.
Note that this option is unable to emulate double bytes, such as Big-5 or Unicode characters on the remote PC. Windows Message
When selected, a Windows message will be broadcasted after Disable decoding.
Intercept the decode message in your application. Call Windows API (ReadMsgQueue) in your application to retrieve the decoded data.
Windows Event
When selected, a Windows event will be broadcasted after Disable decoding.
Intercept the decode event in your application. Call Windows API (ReadMsgQueue) in your application to retrieve the decoded data.
Note: (1) Refer to CipherLab WinCE Products Programming Guide (C/C++) or 9400 .NET Programming Guide for details on Windows Message and Windows Event. Sample programs are provided by request. (2) For the use of a different program rather than 94ReaderConfig.exe, a dynamic-link library (DLL) file is provided. Auto ENTER
This function can spare you the trouble of pressing the [Enter] Scan + ENTER key on the mobile computer to confirm each scan. It will automatically add an ENTER character in front or to the end of one scan.
No Scan + ENTER ENTER + Scan Auto ENTER Character
*Auto ENTER must be enabled.
Prefix String
0~10 characters
None Carriage Return Tab Space Comma Semicolon
Carriage Return
NULL
93
Page 106
9400 Mobile Computer Reference Manual
Suffix String
0~10 characters
NULL
Display Code Type
Select the check box to prefix the code type to barcode data after Disabled decoding a barcode.
Display Code Length
Select the check box to suffix the code length to barcode data Disabled after decoding a barcode.
Display RFID UID
Select the check box to display UID after decoding an RFID tag.
Display RFID User Data
Select the check box to display user data after decoding an RFID Disabled tag.
Field Delimiter
Decide whether or not to use a delimiter to separate data fields ‘ , ’ (comma) after decoding a barcode or an RFID tag, Enabled
Code type, barcode data, and code length if more than one field is displayed
UID and user data if both are displayed 7.5 NOTIFICATIONS (FOR GOOD READ) Tap the [Notifications] button on the General tab to configure how you want to be notified of a successful decoding. Default
Sound / Vibration Good Read via speaker
Mute, or Sound 1~9
Sound 1
Good Read via buzzer
Specify frequency and duration
0 (= Disable)
Good Read via vibrator
0~5.0 (sec.)
Duration 0~255 (0.1 sec.); 0 = Disable the buzzer 0 (= Disable)
0 = Disable the vibrator
Good Read LED Select the check box to enable Good Read LED. The LED will Disable become green to indicate a successful decoding.
7.6 SYMBOLOGY SETTINGS For barcode settings, tap the Symbologies tab.
Refer to Appendix I - Scan Engine Settings for the symbologies or RFID tags supported by a scan engine.
Refer to the Symbology Settings Table in Appendix II - Linear Imager (CCD), Laser (SE950).
Refer to the Symbology Settings Table in Appendix III - 2D Imager.
94