8500 Series Mobile Computer Reference Manual (8500/8570/8580/8590): TROUBLESHOOTING

Pages 105 to 107 of 107, from 8500 Series Mobile Computer Reference Manual (8500/8570/8580/8590)

The original document is the PDF (4.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the CipherLab 8500

Page 105

Appendix II TROUBLESHOOTING The mobile computer cannot be turned on when you press the POWER key…

Make sure the battery pack is installed properly. Re-charge the battery inside the mobile computer and monitor the charging status. (see 3.5) If the battery is faulty, replace it with a fresh and fully charged battery then. Charging error…

Make sure the power cord is well connected between the cradle/charger and an outlet. Check if the battery contacts of the battery itself and the battery compartment are clean. Try to re-charge the battery and monitor the charging status. Warning!

Only use batteries or charging device manufactured by CipherLab. The use of wrong battery or charging device could result in damage to human body or the product itself, and will void your warranty.

The keyboard input seems not working properly…

Perform the keyboard test. (see 3.3.4) If the problem persists, slide the battery latch to reload the battery pack. Then perform the test again.

The reader does not scan… Low battery, Check if the battery icon on the screen indicates a low battery status. If so, replace it with a fresh battery then.

If the problem persists, check if the battery contacts get dirty or the battery pack does not fit to the compartment.

Regarding the barcode or RFID reader, Perform the reader test to see if the reader is working. (see 3.3.1 or 3.3.9) If the problem persists, slide the battery latch to reload the battery pack. Then perform the test again.

95

Page 106

8500 Series Mobile Computer Reference Manual

The reader does not decode after scanning… Unreadable barcode, Check if the barcode is defaced. A defaced barcode may not be readable. Un-programmed to read, Check if the scanner is programmed to read the symbologies (types of barcode) that you are trying to read.

Try scanning a test barcode of the symbology you are trying to read. Dirty scan window, Check if the scan window gets dirty. Wipe it with a clean and dry cloth, and try again. Out of scanning range, Try adjusting the scanning distance from the scanner to the barcode. The mobile computer cannot transmit/receive data to/from a host computer or other devices… Over IR port, Make sure the mobile computer's infrared port is pointed directly to the infrared port of another IR device. The distance between the mobile computer and a target device is within proper range, and no obstacles in between. Try to establish connection again.

Via Bluetooth, Make sure the distance between the mobile computer and a target device is within proper range. Try to establish connection again.

Check if the relevant settings are correct. (see 3.7) Check if the connection is working properly. (see 3.7) Over RS-232 port via cradle, Check if the RS-232 connection is correct and secured. Make sure the serial port parameters on the host are configured to match the serial parameters on the mobile computer. Try to establish connection again.

Make sure the mobile computer is well seated inside the cradle. DO NOT remove the mobile computer or disconnect the cradle before communications are done.

If the problem persists, run the IR Echo Test to check the IR interface between the mobile computer and the cradle. (see 3.3.8)

96

Page 107

Appendix II Troubleshooting Over MODEM port via cradle, Check if the modem connection is correct and secured. Make sure the modem parameters are configured to match the parameters on the mobile computer. Try to establish connection again.

Make sure the mobile computer is well seated inside the cradle. DO NOT remove the mobile computer or disconnect the cradle before communications are done.

If the problem persists, run the IR Echo Test to check the IR interface between the mobile computer and the cradle. (see 3.3.8)

About abnormal response… The LED or LCD seems not working properly, Perform the LCD & LED test. (see 3.3.3) If the problem persists, reload the battery pack and perform the test again. The buzzer seems not working properly, Perform the buzzer test. (see 3.3.2) If the problem persists, reload the battery pack and perform the test again. The mobile computer seems not working properly, First upload all data to a computer, and then perform the memory test. (see 3.3.5) If the problem persists, reload the battery pack and perform the test again. The touch screen seems not working properly, Perform the touch screen test. (see 3.3.6) If the problem persists, reload the battery pack and perform the test again. The vibrator seems not working properly, Perform the vibrator test. (see 3.3.7) If the problem persists, reload the battery pack and perform the test again.