Page 49

Chapter 3 SYSTEM MENU System Menu is generated by a powerful utility, which offers an interface for engineers (programmers or system integrator) to view system information, change the configuration parameters, download programs and run diagnostics. This menu is designed for engineering tests and maintenance ONLY. For this reason, it provides password protection to prevent unauthorized users from accidentally changing system settings. Warning!

System Menu is NOT for the use of any end users. The system password helps ensure system safety and integrity.

How to access System Menu? 6) Turn off the mobile computer. 7) Press [7] + [9] + [Power].

39

Page 50

8400 Series Mobile Computer Reference Manual

IN THIS CHAPTER 3.1 Information............................................................... 40 3.2 Settings ................................................................... 42 3.3 Tests ....................................................................... 46 3.4 Memory.................................................................... 48 3.5 Power ...................................................................... 49 3.6 Load Program............................................................ 50 3.7 Bluetooth Menu ......................................................... 53 3.8 SD Card Menu ........................................................... 62 3.9 Ethernet Cradle Menu ................................................. 64 3.10 Serial PPP Menu ....................................................... 67 3.11 Wi-Fi Menu.............................................................. 70

3.1 INFORMATION Here provides important system information to help diagnose the system.

System Menu | 1. Information H/W

Hardware version

S/N

A serial number assigned to the mobile computer

M/D

Manufacturing date

KNL

Kernel version

LIB

C library version

BSC

BASIC Run-time version, if a BASIC application is downloaded

USR

Application program version

DEV

6-digit code for optional hardware configurations

For example, 2400-01 indicates the 39-key mobile computer is equipped with Laser scan engine and 802.11b/g connectivity.

40

Page 51

Chapter 3 System Menu

3.1.1 UNDERSTANDING DEVICE CODE Device Code Modular Component

Types

1st digit

0= none

Reader module

1= CCD scan engine 2= Laser scan engine 3= 2D scan engine 2nd digit

Wireless module

4= Bluetooth + 802.11b/g

(8470)

5= Bluetooth only

(8400)

3rd digit

Reserved

0

4th digit

Reserved

0

5th digit

Keypad module

Keypad hardware version

6th digit

Keypad Layout

0= 29-key 1= 39-key

41

Page 52

8400 Series Mobile Computer Reference Manual

3.2 SETTINGS You can change the default settings here.

System Settings

Default Values

Clock

Current time

Backlight

20 seconds at level 2, backlight shade enabled

Contrast

Level 4

Auto Off

10 minutes

Power On Options

Program Resume

Key Click

Tone 2

Buzzer Volume

High volume level

USB VCOM No.

Fixed

USB Charge Current

500 mA

System Password

Open access

Font

System font

Reset to Default

Load factory settings

Reset Reader

Restore default reader settings

Upgrade Reader FW

Upgrade 2D reader firmware (For maintenance use only)

3.2.1 CLOCK Set date and time for Real Time Clock. Enter two digits for the year, e.g. 04 for 2004.

3.2.2 BACKLIGHT Set the backlight duration for the keypad and LCD.

Enter a value between 0 and 9999 (second). Press the arrow keys (Up) (Down) to adjust the backlight level (4 levels). Press the

42

(Left) key to adjust the shade effect.

Page 53

Chapter 3 System Menu

3.2.3 CONTRAST Set the contrast level for the LCD.

Press the arrow keys

(Up)

(Down) to adjust the contrast level.

3.2.4 AUTO OFF The mobile computer will be turned off automatically when no operation is taking place during a specified period of time. Enter a value between 0 and 999 (minute). Note: To disable this function, enter 0.

3.2.5 POWER ON (& WAKEUP EVENT) OPTIONS Set the startup screen once the mobile computer is turned on, and specify which events will wake up the mobile computer: Power On Options Press the arrow keys and then press [ENTER].

(Up)

(Down) to select “Program Resume” or “Program Restart”,

Program Resume: When selected, the mobile computer will start from the last session of program before it is turned off.

Program Restart: When selected, the mobile computer will start from the first session of the program.

WakeUp Events The specified events can wake up the mobile computer when the conditions are met. Press the arrow keys (Up) (Down) to select a specific event, and press [ENTER] to determine when it is treated as a wake-up event or not.

PwrKey: If yes, it will wake up the mobile computer upon pressing the Power key. RS232: If yes, it will wake up the mobile computer upon connecting the RS-232 cable. RS232_RXD: If yes, it will wake up the mobile computer upon receiving a specific signal via the RS-232 cable.

USB: If yes, it will wake up the mobile computer upon connecting the USB cable. Charging: If yes, it will wake up the mobile computer upon getting charged via the cradle or direct charging.

Charged: If yes, it will wake up the mobile computer upon completion of charging. Alarm: If yes, it will wake up the mobile computer upon the alarm time is up. Alarm can be set up through programming only.

43

Page 54

8400 Series Mobile Computer Reference Manual

3.2.6 KEY CLICK The system will produce an audible signal when any key on the keypad is pressed. The current value is highlighted. Select a desired tone for the buzzer or mute it.

3.2.7 BUZZER VOLUME Set the buzzer volume.

Press the arrow keys

(Up)

(Down) to adjust the volume level (3 levels).

3.2.8 USB VCOM NO By default, it is set to use one virtual COM port for all (=FIXED), regardless of how many 8400 mobile computers are connected to PC when USB Virtual COM is in use. This setting requires you to connect one 8400 at a time, and will facilitate configuring a great amount of 8400 mobile computers via the same virtual COM port (for administrators’ or factory use). If necessary, you can have it set to use variable virtual COM port (=Change by Serial Number), which will vary by the serial number of each different 8400.

Press the arrow keys by Serial Number”.

(Up)

(Down) to select between “Fixed” and “Change

3.2.9 USB CHARGE CURRENT By default, the USB charging current is set to 500 mA. For direct charging via the USB cable without supplying a power adaptor, the standard charging current is 500 mA. If you connect the mobile computer to a USB hub, the charging current may be insufficient. In that case, change the charging current to 100 mA after connecting the USB cable. It will take a longer time to charge to full.

Press the arrow keys

(Up)

(Down) to select between “500 mA” and “100 mA”.

Note: (1) USB direct charging, 500 mA: USB icon (2) USB direct charging, 100 mA: Highlighted USB icon (3) 5V charging from the adaptor: Plug icon

3.2.10 FONT Font version information can be viewed here. It displays System Font if there is no custom font file. If a multi-language font file is downloaded, you will be able to select a font from the list.

44

Page 55

Chapter 3 System Menu

3.2.11 SYSTEM PASSWORD Set a password to control user access to System Menu, Program Manager and Kernel Menu. The password can be up to eight alphanumeric characters. Note: The password is case-sensitive. To disable a previous password, enter blank on the "Input new password" and "Verify password" screens.

3.2.12 RESET TO DEFAULT Reset system settings to the default values, except for the reader settings.

3.2.13 RESET READER Reset reader settings to the default values.

3.2.14 UPGRADE READER FW Upgrade 2D reader firmware if necessary.

45

Page 56

8400 Series Mobile Computer Reference Manual

3.3 TESTS Here provides functional tests for key parts.

3.3.1 READER Test the reading performance of the scanner. The supported symbologies depend on the scan engine you use. Refer to 1.6 Data Capture for symbologies that are enabled by default. For symbologies that are disabled by default, they must be enabled through programming.

Press [SCAN] to start. To stop and exit the test, press any key. 3.3.2 BUZZER Test the buzzer with different frequency/duration combinations.

To stop and exit the test, press any key. 3.3.3 LCD & LED Test the LCD display and LED indicators.

To stop and exit the test, press any key. 3.3.4 KEYBOARD Test the rubber keys. Press any key and its corresponding character will be shown on the screen.

To stop and exit the test, press [ESC]. 3.3.5 MEMORY Test the data memory (SRAM), and the results will be shown on the screen.

To stop and exit the test, press [ESC]. Warning!

46

The contents of the data memory (SRAM) will be wiped out after test.

Page 57

Chapter 3 System Menu

3.3.6 ECHO TEST After a physical connection is established properly, run a test utility on your computer and start the test on your mobile computer. Select a desired baud rate if necessary.

To stop and exit the test, press [ESC]. Interface

Description

RS-232

This echo test is to verify connectivity via the RS-232 cable EchoTest.exe between the mobile computer and a host computer.

Modem

This echo test is to verify the connectivity of the Modem EchoTest.exe Cradle. A telephone line must be connected to the Modem Cradle.

USB

This echo test is to verify connectivity via the USB cable between the mobile computer and a host computer.

Test Utility

EchoTest.exe for

USB VCOM Echo, The mobile computer works as a Virtual COM generic USB device.

USB HID, The mobile computer works as an input device; select keyboard type and Caps Lock status for Any text editor for HID running a test.

3.3.7 VIBRATOR Test the vibrator.

To stop and exit the test, press [ESC].