Page 107

Appendix II TROUBLESHOOTING CANNOT TURN ON WHEN PRESSING POWER KEY Make sure the battery pack is installed properly. Re-charge the battery inside the mobile computer and monitor the charging status. (See 3.5 Power.)

If the battery is faulty, replace it with a fresh and fully charged battery then. CHARGING ERROR If using the USB cable for direct charging, make sure a suitable charging current is selected.

(See 3.2.9 USB Charge Current.)

If joining the power adaptor to the USB or RS-232 cable, make sure it is well connected between the power jack and an outlet.

If using a cradle or charger, make sure the power cord is well connected the cradle/charger and an outlet.

Check if the battery contacts of the battery itself and the battery compartment are clean.

Try to re-charge the battery and monitor the charging status. Warning!

Only use batteries or charging device manufactured by CipherLab. The use of wrong battery or charging device could result in damage to human body or the product itself, and will void your warranty.

BUZZER SEEMS NOT WORKING Perform the buzzer test. (See 3.3.2 Buzzer.) If the problem persists, reload the battery pack and perform the test again. LED INDICATORS SEEM NOT WORKING Perform the LCD & LED test. (See 3.3.3 LCD & LED.) If the problem persists, reload the battery pack and perform the test again. LCD SEEMS NOT WORKING Perform the LCD & LED test. (See 3.3.3 LCD & LED.) If the problem persists, reload the battery pack and perform the test again.

97

Page 108

8400 Series Mobile Computer Reference Manual

KEYPAD SEEMS NOT WORKING Perform the keyboard test. (See 3.3.4 Keyboard.) If the problem persists, reload the battery pack and perform the test again. VIBRATOR SEEMS NOT WORKING Perform the vibrator test. (See 3.3.7 Vibrator.) If the problem persists, reload the battery pack and perform the test again. MOBILE COMPUTER SEEMS NOT WORKING Upload all data to the host and perform the memory test. (See 3.3.5 Memory.) If the problem persists, reload the battery pack and perform the test again. CANNOT SCAN BARCODES LOW BATTERY CONDITION Check if the battery icon on the screen indicates a low battery status. If so, replace it with a fresh battery then.

If the problem persists, check if the battery contacts get dirty or the battery pack does not fit to the compartment.

BARCODE READER PROBLEM Perform the reader test to see if the reader is working. (See 3.3.1 Reader.) If the problem persists, reload the battery pack and perform the test again. CANNOT DECODE DATA AFTER SCANNING UNREADABLE BARCODE Check if the barcode is defaced. A defaced barcode may not be readable. UN-PROGRAMMED TO READ Check if the scanner is programmed to read the symbologies (types of barcode) that you are trying to read.

Try scanning a test barcode of the symbology you are trying to read. DIRTY SCAN WINDOW Check if the scan window gets dirty. Wipe it with a clean and dry cloth, and try again.

98

Page 109

Appendix II Troubleshooting

OUT OF SCANNING RANGE Try adjusting the scanning distance from the scanner to the barcode. CANNOT TRANSMIT/RECEIVE DATA USING RS-232 CABLE Check if the RS-232 connection is correct and secured. Make sure the serial port parameters on the host are configured to match the serial parameters on the mobile computer. Try to establish connection again.

If the problem persists, run the Echo Test to check if the RS-232 interface between the mobile computer and the host is working. (See 3.3.6 Echo Test.)

USING USB CABLE Check if the USB connection is correct and secured. Check if the USB driver has been installed. Driver version 5.3 or later is required. If the problem persists, run the Echo Test to check if the USB interface between the mobile computer and the host is working. (See 3.3.6 Echo Test.)

Note: (1) If you are using USB Virtual COM for the first time, you must install its driver from the CD-ROM. Driver version 5.3 or later is required. Please remove older versions! The virtual COM port will not be assigned until the USB port is in use. (2) For Standard USB cable, it will release COM port in the following conditions: (i) detach the cable from the mobile computer directly, (ii) detach the cable from the cradle directly, (iii) when the cable is attached to the cradle, take away the mobile computer, (iv) the mobile computer is turned off, (v) no application is running on the mobile computer, or COM port is shut down. For applications that require COM port to be occupied all the time, it is suggested to use 308 USB Virtual COM Interface cable instead.

VIA BLUETOOTH Make sure the distance between the mobile computer and a target device is within proper range. Try to establish connection again.

Check if the relevant settings are correct. (See 3.7 Bluetooth Menu.) If the problem persists, run the Echo Test to check if the connection is working properly. (See 3.7.4 Echo Tests.)

VIA WI-FI Make sure the mobile computer is connected to an access point properly, under the same SSID. Try to establish connection again.

Check if the relevant settings are correct. (See 3.11 Wi-Fi Menu.) If the problem persists, run the Echo Test to check if the connection is working properly. (See 3.11.6 Echo Tests.)

99

Page 110

8400 Series Mobile Computer Reference Manual

VIA ETHERNET CRADLE Check if the Ethernet connection is correct and secured. Make sure the networking parameters are configured properly. Try to establish connection again.

Make sure the mobile computer is well seated inside the cradle. DO NOT remove the mobile computer or disconnect the cradle before communications are done.

If the problem persists, run the Echo Test to check if the Ethernet connection is working properly. (See 3.9.3 Echo Tests.)

VIA MODEM CRADLE Check if the modem connection is correct and secured. Make sure the modem parameters are configured properly. Try to establish connection again.

Make sure the mobile computer is well seated inside the cradle. DO NOT remove the mobile computer or disconnect the cradle before communications are done.

If the problem persists, run the Echo Test to check if the PPP connection is working properly. (See 3.10.3 Echo Test.)

If the problem persists, run the Echo Test to check if the MODEM interface between the mobile computer and the cradle is working. (See 3.3.6 Echo Test.)