Page 9

[20] Nordic [21] Portugal [22] Russian [23] Slavic [24] Polish [25] Turkish [26] Slovak(CP1250) Default: System Font

Tests 1. Reader To test the reading performance of the scanner. The following barcodes are default to enable: Code 39 Industrial 25 Interleave 25 Codabar Code 93 Code 128 UPCE UPCE with ADDON 2 UPCE with ADDON 5 EAN8 EAN8 with ADDON 2 EAN8 with ADDON 5 EAN13 EAN13 with ADDON 2 EAN13 with ADDON 5 Other barcodes must be enabled through programming. 2. Buzzer To test the buzzer with different Frequency/Duration. Press ENTER key to start and then press any key to stop the test. 3. LCD & LED To test LCD display and LED indicator. Press ENTER key to start and then press any key to stop the test. 4. Keyboard To test the rubber keys. Press a key and the result will be shown on the LCD display. Note that the FN key should be used in conjunction with numeral keys. 5. Memory To test the data memory (SRAM). Note after the test, the contents of the memory space will be wiped out.

Memory 1. Size Information Information includes sizes of the base memory (SRAM), memory card (SRAM) and 7

Page 10

program memory (FLASH) in the unit of kilobytes. 2. Initialize To initialize the data memory (SRAM). Note the contents of the data space will be wiped out after memory initialization.

Power Show the voltages of the main battery and backup battery.

Load Application To download the application program, BASIC run-time or font file. There are three interfaces supported by the system, namely, the Direct-RS232, Cradle-IR and standard IrDA. Download.exe is required when Direct RS232 or standard IrDA interface is used. And IrLoad.exe is required when Cradle-IR is used.

802.11b Menu This item will be displayed only if an 802.11b module is installed. 1. Information It includes the WLAN LIB version, MAC ID, DHCP status, IP address, Subnet Mask, and Gateway. 2. Network Settings DHCP Server will dynamically assign the following IP settings to the terminal if DHCP Server is installed and the option is enabled. These IP Settings also can be configured manually if DHCP is disabled. Please contact your MIS engineer if you don’t know how to configure it. 1). DHCP DHCP stands for Dynamic Host Configuration Protocol. Default: [1] Enable 2). SubNet Mask The number used to identify the IP sub-network, indicating whether the IP address can be recognized on the LAN. Default: 255.255.128.0 3). Local IP Address The address which identifies a location of the terminal on the network must be unique. Default: 0.0.0.0 4). Default Gateway the Gateway IP address is the IP address of a local router in between the forwarding node and the remote network. Default: 0.0.0.0 5). DNS Server Domain Name Server is a distributed, replicated, data query service mainly used on the Internet for translating host names to IP addresses. Default: 0.0.0.0 8

Page 11

3. WLAN Settings The RF settings and their default values are as follows, 1). Local Name Specify name for terminal 8370 Default: the S/N of the 8370 terminal 2). Domain Name The domain name locates the organization or other entity on the Internet. Default: <None> 3). SS ID The SSID is a 32-character (maximum) string identifying the wireless local area network. All APs & terminals within the same service set should have the same SSID. Default: <None> 4). System Scale This option which depends on the Access Point Density determines when the terminal should look for other Access Point that has bigger signal strength. [1] Low [2] Medium [3] High Default: [2] Medium 5). Power Saving Wireless products can be put in lower power consumption mode when “Power Saving” is enabled. Default: [1] Enable 6). Preamble Select either a short preamble or long preamble. Select a short preamble for 8370 terminal with high network traffic; select a long preamble when the network traffic is low. Default: [1] Long 4. Security 1). Authentication 802.11b supports two subtypes of network authentication services: open system and shared key. Open system authentication is used when no authentication is required. Under Share Key Authentication, it involves a shared secret key to authenticate the station to the AP(access point). WEP must be implemented to utilize this. [0] Share Key [1] Open System Default: [1] Open System 2). WEP Menu

WEP Setting 9

Page 12

Wireless Equivalent Privacy (WEP) is an encryption to translate data into a secret code. It provides wireless clients with confidentiality and authentication in an IEEE 802.11b environment. [0] Disable [1] Enable Default: [0] Disable

WEPKey Length When WEP is enabled, Data sent between the client and the access point is scrambled using either a 64-bit or 128-bit key. The higher the level of encryption, the more secure it is. [0] 64 bits [1] 128 bits Default: [1] 128 bits

Default Key Activate one of the four encryption keys Default: [1] WEP KEY1

WEP Key Define the encryption key values for Key1~Key4 using hexadecimal digits. When WEPKey Length “64 Bit” is selected, the user is required to fill in 5 bytes of hexadecimal values as the encryption key. When WEPKey Length “128 Bit” is selected, the user is required to fill in 13 bytes of hexadecimal values as the encryption key.

3). EAP Menu EAP Stands for Extensible Authentication Protocol. The 8370 terminal only supports EAP-MD5. When these features are implemented, a wireless client that associates with an access point cannot gain access to the network until the user performs a network logon. Therefore, Identity and Password are needed when EAP is enabled.

EAP Setting EAP ID EAP Password

5. Echo Tests The terminal will echo the received data from the client or server and also signals a beep. The function is used to measure the coverage of the range, estimate the number of APs and terminals needed, and determine the AP’s deployment topology. 1. Client Mode 2. Server Mode Cipherlab provides TCPServer.exe (only for Client Mode) and TCPDemo.exe for Echo Tests. 10

Page 13

Once the connection of Echo Test is established, the details will be displayed as the illustration below. Sending 033 Recv ok 033

Q: 0070 S: 0133

T: 11M N: 0006

Link Quality (“Q”) will be the most important element, and others are for reference only. Q (Link Quality) 0 ~ 10 Very Poor 10 ~15 Poor 15 ~30 Good 50 ~80 Very Good

T ( Transmit Speed) 1M bps 2M bps 5.5M bps 11M bps

S (Signal Level) 0 ~ 10 Weak 30~60 Moderate Over 60 Strong

N ( Noise Level) 1 Weak 2~3 Moderate 4~5 Strong

3.3 Application The Application module runs on top of the System module. The 8370 Terminal is preloaded with the Application Generator’s run-time program and the following menu will be shown upon powering the unit up:

1. Take data 2. Utilities

The arrow keys can be used to select the menu item, and execute it by pressing the ENTER key. Note if you use the Application Generator to create your application program, you need to download it to the terminal. And for RF models, you need to use the RF Database Manager to handle the in-coming and out-going data to and from the PC. For detailed information, please refer to “8300 Series Application Generator User’s Guide” and “RF Application Generator User’s Guide”.

3.4 Programming the terminal There are three software tools available for developing application programs for the terminal. 1. The Application Generator 2. The “BASIC” Compiler 3. The “C” Compiler Besides, Terminal Emulation program which supports ANSI (VT100& VT220) and IBM is also available. For detailed information, please contact Syntech Information Co., Ltd.

3.5 Programming the communication cradle The communication cradle of the 8370 Portable Data Terminal supports serial IR interface only. Before your PC application starts to communicate with the terminal via its cradle, first you need to configure the cradle through programming. There is a DLL available for this purpose. For more information, please contact Syntech Information Company. 11

Page 14

4. Operations Batteries must be fresh and properly loaded before start operation.

4.1 Keypad operations The 8300 Series Terminals have two keyboard layouts: 24 rubber keys and 39 rubber keys. The functions of some special keys are as follows: SCAN

Scan a barcode. Press this button will trigger the scanner to read a barcode if the scanner port is enabled.

ENTER

Enter. There are two enter keys on the side of the scan key. Normally the enter keys are used for command execution or input confirmation.

ESC

Escape. Usually this key is used to stop and exit current operation.

BS

Back Space. If this key is being pressed down longer than one second, a clear code will be sent.

ALPHA / α

The toggle key for Alphabet / Numeral input. When the system is in alpha-mode, a small icon will be shown on the display. For the 24-key keyboard, each numeral key can be used to generate one of the three capital letters. For example, numeral 2 can be used to produce A, B or C. Pressing the same key twice within one second, will call the letter B. Pressing the same key without halting longer than one second, will cause the three letters to be shown in a circulating way. Only when stop pressing the key for longer than one second or pressing another key, will the system send the real key code to the application program. Pressing the “Alpha” key again, lower case letter can be inputted.

FN

The function key. This key cannot be activated alone, it must be pressed with one numeral key at the same time. For example, FN + 1 generates function #1, FN + 2 generates function #2, etc (up to 9 functions). Also, this key can be combined with the UP/DOWN arrow keys to adjust the contrast of the LCD. And when this key is combined with the ENTER key, it will turn ON/OFF the backlight.

POWER

Power On/Off. To prevent a faulty push, it needs about 1.5 sec continuous pressing to turn On/Off the power.

4.2 Application mode This is the default operation mode when turning on the power. The operation depends on the application module. Please refer to section 4.4. 12

Page 15

4.3 System mode To enter the system menu, you need to press the 7, 9 and POWER keys simultaneously upon power up the terminal. For details of the services provided by the system, please refer to section 4.2.

4.4 Kernel mode To enter the kernel menu, you need to press 7, 9 and POWER keys simultaneously to enter the system menu first, then power off the unit and press 1, 7 and POWER key simultaneously. Or if the battery is just reloaded, then press 1, 7 and POWER key simultaneously will directly go to the kernel. For details of the services provided by the kernel, please refer to section 4.1.

4.5 Application Manager Although the Application Manager is part of the kernel, to enter it, you need to press ‘8’ and POWER key simultaneously. Or if the application program does not exist, the unit will automatically go to the Application Manager’s menu upon power up. The three services: Download, Activate and Upload provided by the Application Manager are explained in Section 4.1. But what if you need to update a program or delete it? For both cases, you need to select the Download menu and select the program to be updated or deleted. The Application Manager then shows the selected program’s information such as Program Name, Download Time, Used and Free Flash memory. And then please input ‘C’ to update the selected program, or input ‘D’ to delete it.

13

Page 16

5. Troubleshooting a)

Cannot connect to the AP. Check if SSID, Authentication, and WEP settings of 8370 are the same as AP’s. Some particular settings : Cisco AP: Authentication must be "Open System". Lucent AP: The Preamble must be "Long". Symbol AP: The power saving must be "disabled" b)

Does not power up after pressing POWER key. Make sure the battery is loaded. Charge the battery and check the charging status. If no charging information shown on the display, reload the battery and check if the battery is properly installed then try again. Call for service if problem persists.

c)

Cannot transmit data or programs via the terminal’s communication port. Check if the cable is plugged tightly, then, Check if host communication parameters (COM port, baud rate, data bits, parity, stop bit) match with the Terminal's.

d)

Keypad does not work properly, Turn off the power then press the 7, 9 and POWER keys simultaneously to enter the system menu. From the system menu, select the Test and then its sub-item KBD. Perform the key-in test. If problem persists, call for service.

e)

Scanner does not scan, Check if the barcodes used are enabled, or Check if battery-low indicator is shown on the LCD display. If yes, charge the battery. If problem persists, call for service.

f)

Abnormal responses,

Open the battery cap and re-load the battery. Enter system menu by pressing 7, 9 and POWER keys simultaneously. Check if the terminal can have a correct response by performing tests. If problem persists, call for service.

14