Page 35
Using the Optical Communication Unit (IT-760IOE) The Optical Communication Unit (IT-760IOE) provides a serial interface (RS-232C) connection between a Pocket PC Terminal and computer for downloading and uploading system data, files, etc. It can also be used to charge the battery pack loaded in the Pocket PC Terminal. The Optical Communication Unit comes with a wall mount unit.
General Guide Top
2 3 4
1
Front
Back
Right
5
16
13 6
14
15
7
16
12
8 9 10 11
Bundled items Bottom
Terminal Support
Terminal Support Screws
Spacers
Screws
33
Page 36
1 2 3 4 5
RS-232C Interface RS-422 Interface (C-IN) RS-422 Interface (C-OUT) AC Adaptor Jack Hook
6
Connection Detector Power Contacts System Operation Indicator
7 8
9
Communication Status Indicator
10
Charge Indicator
11
Power Indicator
12 13 14
IR Interface Power Switch Base
15
DIP Switches
16
Wall Hook Holes
34
For uploading and downloading system data and files with a computer For communication between Optical Communication Units For connection of the AC adaptor Secures the Pocket PC Terminal in place when on a wallmounted Optical Communication Unit. Detects whether the Pocket PC Terminal is correctly mounted onto the Optical Communication Unit. Supply power to the Pocket PC Terminal. Indicates the current operational status of the system. This indicator should light green a short while after you mount the Pocket PC Terminal onto the Optical Communication Unit. This system is not operating correctly if the system operation indicator does not light. Off: System problem, or no communication with any of the Pocket PC Terminals mounted on the Optical Communication Units Lit Green: System operating normally, communication being performed with at least one of the Pocket PC Terminals mounted on the Optical Communication Units Indicates the current communication status. Off: No communication Flashing Green: Communication in progress Lit Red: Problem with connection between Optical Communication Units Indicates the current status of the charger operation for the lithium ion battery pack load in the Pocket PC Terminal. Off: No charging Lit Red: Charging Flashing Red: Battery pack abnormality Lit Green: Charging finished Indicates the power status of the Optical Communication Unit, and whether a Pocket PC Terminal is mounted. Off: Power off Lit Red: Power on, Pocket PC Terminal not mounted Lit Green: Power on, Pocket PC Terminal mounted For non-contact infrared data communication with a Pocket PC Terminal Turns power on and off. Rotate the base 180 degrees (so its high end is facing downwards) when configuring the Optical Communication Unit for wall mounting. Use these switches to change the basic configuration of the Optical Communication Unit. Wall hooks (spacers + screws) enter these holes for wall mounting.
Page 37
Optical Communication Unit Power Requirements Use the AC adaptor that comes with the Optical Communication Unit to power it. Be sure to connect the AC adaptor to the Optical Communication Unit before starting a data communication operation with a Pocket PC Terminal. Power is supplied to the Pocket PC Terminal from the Optical Communication Unit.
Using the Optical Communication Unit 1. Plug the AC adaptor into a wall outlet. 2. After confirming that the Optical Communication Unit is turned off, plug the AC adaptor cord into the AC adaptor jack on the top of the unit.
3. After confirming that both the Optical Communication Unit and your computer are turned off, use an RS-232C cable (DT881RSC, DT-882RSC, DT-883RSC, DT-887AX) to connect the RS-232C interface on the top of the Optical Communication Unit (remove the interface cap) to your computer. • Leave the interface cap in place if you do not plan to use the RS-232C interface. 4. Turn on the Optical Communication Unit and your computer. • The power indicator on the Optical Communication Unit should light red at this time. 5. Mount a Pocket PC Terminal onto the Optical Communication Unit, making sure the IR port on the side of the terminal is in contact with the IR port of the Optical Communication Unit. This should cause the power indicator on the Optical Communication Unit to turn green and the charge indicator to light red, indicating that charging has started. Charge Indicator Off:
No charging
Lit Red:
Charging
Flashing Red: Battery pack abnormality Lit Green:
Charging finished
• The system operation indicator flashes green if system operation is normal and data communication is being performed (when two or more Optical Communication Units are connected.)
35
Page 38
Caution ■ Make sure you charge the battery pack in a location where the temperature is within the allowable range for charging. • The allowable range for charging the battery pack is shown below. Charging in a location where the temperature is outside this range can lower battery pack performance and service life, and can also lead to leaking and overheating of the battery pack. Allowable Temperature for Charging: 0°C to 40°C Important • Pocket PC Terminal IR data communication uses a high-sensitivity communication component. • To help ensure proper data communication, avoid using cell phones and other devices that emit radio waves in the vicinity of the Pocket PC Terminal while data communication is taking place. The cell phone or other device should be at least 30cm from the Pocket PC Terminal. • If the charge indicator does not light during charging, remove the Pocket PC Terminal from and then remount it onto the Optical Communication Unit. If the charge indicator does not light, remove the battery pack from the Pocket PC Terminal, reload the same battery pack, and try charging again. If the charge indicator still does not light, it indicates that the battery pack is defective. Replace the battery pack with a new one. • Never try to use the Optical Communication Unit to charge a battery other than the one specifically indicated in this manual. • A fully charged battery pack naturally discharges little by little, even if you are not using it. Because of this, the best policy is to wait until just before you need a battery pack before you charge it. • For best charging results, keep the contacts of the Optical Communication Unit, the Pocket PC Terminal, and the battery pack clean by wiping them periodically with a cotton swab or a dry cloth.
36
Page 39
DIP Switch Settings The DIP switches are location on the back of the Optical Communication Unit. You can control the basic configuration of the Optical Communication Unit by turning the DIP switches on and off in various combinations. ■ Flow Control 1 2 3 4 5 6 7 8 9 10
None X ON/X OFF RS/CS Special Software
9 OFF ON OFF ON
10 OFF * OFF ON ON
■ Optical Communication Unit – Host Data Rate 6 7 8 2,400bps OFF OFF OFF 4,800bps ON OFF OFF 9,600bps OFF ON OFF * 19,200bps ON ON OFF 38,400bps OFF OFF ON 57,600bps ON OFF ON 115,200bps OFF ON ON
■ Pocket PC Terminal – Optical Communication Unit Data Rate 1 2 38,400bps OFF ON 115,200bps ON OFF * * Indicates initial default settings.
■ Connection Type 3 4 5 With Host OFF OFF ON (No daisy chain) * OFF (Daisy chain) Daisy Chain ON OFF OFF Intermediate Unit Daisy Chain ON OFF ON Terminator Unit
Important Use only the settings shown above. Other settings other than those noted above are for special maintenance modes.
37
Page 40
Wall Mounting the Optical Communication Unit You can use the Wall Mount Unit that comes with the Optical Communication Unit to configure it for wall mounting. 1. Attach the terminal support to the Optical Communication Unit.
2. Secure the terminal support in place with the two screws.
3. Remove the two screws holding the hook in place. Next, move the hook to the right side screw holes and secure it in place with the screws. Left side
Right side (Move hook here for wall-mounting.)
The illustration on the right shows when the hook on the Optical Communication Unit is removed.
4. Remove the two screws (top and bottom) that secure the base of the Optical Communication Unit.
38
Page 41
5. Press in on the sides of the base at the four locations indicated by arrows in the illustration to disengage the base tabs, and then remove the base from the Optical Communication Unit.
6. Holding the base against the wall where you plan to affix it use a pencil or pen to mark the locations of each wall hook (spacer + screw). Make sure the high end of the base is facing downwards when you perform this step.
7. Prepare the wall hooks by sliding a spacer over each of the provided wood screws so the head of the spacer is on the same end as the head of the screw. Next, drive the screws into the wall at the two locations you marked in step 5. Make sure the spacer head is on the same end as the head of the screw. You will not be able to hook the base unit onto the wall hooks (spacer + screw) if the spacer is backwards.
8. Reattach the base to the Optical Communication Unit, making sure that the high end of the base is on the same side of the Optical Communication Unit as the terminal support you installed in steps 1 and 2. Secure the base to the Optical Communication unit with the two screws (top and bottom).
39
Page 42
9. Hook the holes of the Optical Communication Unit base onto the wall hooks and slide the Optical Communication Unit down to secure it.
Important Be sure to periodically check wall mounted Optical Communication Units for looseness and tighten the screws whenever necessary.
Daisy Chaining Multiple Optical Communication Units (IT-760IOE) You can use optional Daisy Chain Cables (DT-888RSC) to daisy chain up to seven Optical Communication Units for simultaneous uploading and downloading of data between a computer and multiple Pocket PC Termnals.
To daisy chain multiple Optical Communication Units Connect the [C-OUT] terminal of the Optical Communication Unit that is closer to the host computer to the [C-IN] terminal of the next Optical Communication Unit the computer in the chain. • Example: 3-unit daisy chain
To your PC
Caution Do not connect the [C-OUT] terminal and the [C-IN] terminal to the telephone line.
40
Page 43
Optical Communication Unit (IT-760IOE) Specifications Model: IT-760IOE IR port: Interface: IrDA Ver.1.0 Standard Synchronization: Asynchronous Data Rate: 38,400, 115,200bps RS-232C: Synchronization: Asynchronous Data Rate: 2,400 to 115,200bps RS-422: Synchronization: Asynchronous Data Rate: 9,600 to 115,200bps Power Supply: Output: DC5V 1A Charging System: Fixed voltage (with voltage control) Approximate Charge Time: 4 hours (Standard Battery Pack); 8 hours (Largecapacity Battery Pack) Power Requirements: Special AC Adaptor (DT-825ADP) Consumption Current: Approximately 900mA Operating Temperature: 0 to 40°C (32 to 104°F) Dimensions: 110(W) × 220(D) × 111(H) mm Weight: Approximately 530g
41