Page 49

Using the Dual Charger The optionally available Dual Charger (DT-5022CHG) lets you charge two battery packs. In this configuration, charging of the second battery pack starts after charging of the first battery pack is complete.

General Guide Side

Bottom

Top

3

1

1

4

4

4

4

2

3

3

Bundled items Attachment

1

Charge Indicator

Indicates the current status of the charge operation. Off: No charging Lit Red: Charging Flashing Red: Battery pack abnormality Lit Green: Charging finished

2

AC Adaptor Jack

For connection of the AC adaptor

3

For connection to another Dual Charger Dual Charger Connection Terminal

4

Connection Attachment

Screws

Use this attachment to secure two Dual Charger units together.

Important Each Dual Charger comes with a connection attachment, even though you need only one connection attachment to secure two Dual Charger units. Keep the extra one on hand as a spare.

47

Page 50

Using the Dual Charger 1. Plug the optionally available special AC adaptor into a wall outlet.

2. Plug the AC adaptor cord into the AC adaptor jack of the Dual Charger. 3. Mount a Rechargeable Battery Pack onto the Dual Charger, making sure the battery pack’s terminals are oriented correctly. • The charge indicator on the Dual Charger should light red, indicating that charging has started.

Charge Indicator Off:

48

No charging

Lit Red:

Charging

Flashing Red:

Battery pack abnormality

Lit Green:

Charging finished

Page 51

Daisy Chaining Dual Charger Units You can use the following procedure to daisy chain up to three Dual Charger units and power them with a single AC adaptor. 1. Remove the connector covers of Dual Charger units as required.

Remove these covers.

2. Connect the connection terminals of the Dual Charger units.

3. Install the connection attachment to the bottoms of the charger units as shown in the illustration, and secure it in place with the two attachment screws.

49

Page 52

Dual Charger (DT-5022CHG) Specifications Model: DT-5022CHG Charging System: Fixed voltage (with voltage control) Approximate Charge Time: 2.5 hours (1 Standard Battery Pack); 5 hours (1 Large-capacity Battery Pack); 5 hours (2 Standard Battery Packs); 10 hours (2 Large-capacity Battery Packs) Power Requirements: Special AC Adaptor (MPC-577ADP) Consumption Current: Approximately 650mA Operating Temperature: 0 to 40°C (32 to 104°F) Dimensions: 110(W) × 100(D) × 49(H) mm Weight: Approximately 154g

50