Page 25
DinionXF | Installation Manual
EN | 25
Install I/O --> Alarm submenu Function
Selection
ACTIVE
NONE, HIGH, LOW Selects active_HIGH or active_LOW for the alarm input connector. Select NONE to disable alarm switching.
ACTION
NONE, MODE1, MODE2, MODE3
Selects the operating mode of the camera upon switching the alarm input.
ALARM OUT
VMD, REMOTE
Select VMD to close the output relay upon VMD alarms. Select REMOTE to make the output relay available to remote communication devices.
EXIT
Description
Return to the I/O menu
Install sync submenu Function
Selection
Description
SYNC
INTERNAL, LINE LOCK, HV LOCK, GENLOCK
Select INTERNAL for free running camera operation, select LINE LOCK to lock to the power supply frequency, select HV LOCK to lock to the signal supplied to the external sync input, select GENLOCK to lock the subcarrier as well.
DETECTED SYNC
Shows the actual sync mode used by the camera.
VPHASE
0, 2, … 358
Adjusts the vertical phase offset (when in LINE LOCK mode and a valid power supply frequency is detected).
HPHASE
-25, …, 0, … +125
Adjust the horizontal phase offset (when in EXT lock mode and a valid input signal is detected)
SUB PHASE
0, 2, … 358
Adjusts the sub-carrier phase offset (when in EXT LOCK mode and a valid sub-carrier is detected).
EXIT
Return to the INSTALL menu
Note VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal.
Bosch Security Systems | 2003-10 | V0.5
Page 26
DinionXF | Installation Manual
EN | 26
Install ID submenu Function
Selection
CAMERA ID
ID POS
Description Enter a 16 character camera name string. Use LEFT/RIGHT to change position in the string, use UP/DOWN to select the character. Use SELECT to exit the string edit screen.
OFF, TOP, BOT
EXIT
Select TOP to display the camera ID in the upper left corner; select BOT for the lower left corner. The ID string is not displayed when the OSD menus are open. Return to the INSTALL menu
Defaults submenu Function
Selection
Description
ALL DEFAULTS
Select to restore the factory defaults. A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.
EXIT
Return to MODE menu
Camera Control Communication This camera is equipped with a coaxial communications transceiver. In combination with VP-CFGSFT, the camera can be adjusted from the headend side of the coaxial cable. All menus can be accessed remotely giving full control of the camera. With this communication it is also possible to disable the local keys on the camera. To avoid loss of communication on an installed camera, the COMMUNICATION ON/OFF selection is NOT available while using remote control. This function can only be accessed with the camera buttons.
Bosch Security Systems | 2003-10 | V0.5
Page 27
DinionXF | Installation Manual
EN | 27
Technical specification 1/2" CCD versions Type number
LTC 0610/11
LTC 0610/21
LTC 0610/51
LTC 0610/61
Standard
PAL
NTSC
PAL
NTSC
Active pixels
752x582
768x492
752x582
768x492
Rated supply voltage
24 VAC or 12 VDC 12-28 VAC (50/60 Hz) 12-36 VDC
Min illumination
0.18 lx 0.08 lx with NightSense
230 VAC 50Hz, (/50) 110 VAC 60Hz, (/60) Range: 100-230 VAC ±10% 50/60Hz
1/3" CCD versions Type number
LTC 0485/11
LTC 0485/21
LTC 0485/51
LTC 0485/61
Standard
PAL
NTSC
PAL
NTSC
Active pixels
752x582
768x492
752x582
768x492
Rated supply voltage
24 VAC or 12 VDC 12-28 VAC (50/60 Hz) 12-36 VDC
Min illumination
< 0.24 lux < 0.1 lux (with Nightsense)
230 VAC 50Hz, (/50) 110 VAC 60Hz, (/60) Range: 100-230 VAC ±10% 50/60Hz
All versions Imager
Interline CCD
Resolution
540 TVL
SNR
> 50 dB
Video output
1 Vpp, 75 Ohm
Y/C output
Y: 1 Vpp C: 0.3 Vpp
Synchronization
Internal or HV-lock or Genlock or Line Lock selectable
Shutter
AES (1/60 (1/50) to 1/100000), Flickerless, Fixed selectable
Bosch Security Systems | 2003-10 | V0.5
Page 28
DinionXF | Installation Manual
EN | 28
All versions NightSense
On, Off, Auto
Sens Up
Adjustable from OFF to 10x
Auto black
On, Off selectable
AGC
AGC on or off (0 dB) selectable. Maximum level selectable upto 28 dB
XF-DYN
Automatic dynamic range enhancement level selectable
DNR
Automatic noise filtering ON/OFF selectable
Contour
Sharpness enhancement level selectable
BLC
BLC On or Off selectable, with programmable area
White balance
Automatic 2500 - 9000K (with AWB hold mode and manual mode)
Color saturation
Adjustable from monochrome (0%) to 133% color
Lens Mount
C and CS compatible
ALC lens
Video or DC iris auto detect
Power consumption
<5W
Dimensions
58 x 66 x 122 mm (HxWxL) without lens
Weight
450g without lens
Tripod Mount
Bottom (isolated) and Top ¼" 20 UNC
Operating temperature
-20° to 50° C
Controls
OSD with softkey operation
Bosch Security Systems | 2003-10 | V0.5
Page 29
DinionXF | Installation Manual
EN | 29
Accessories Power transformers • • • •
TC1334 TC120PS TC220PSX-24 TC220PS
120VAC, 60Hz - 24VAC, 30VA 120VAC, 60Hz - 15VDC, 9VA 220-240VAC, 50/60Hz - 24VAC, 30VA 220-240VAC, 50/60Hz - 15VDC, 9VA
Interface box: •
VP-CFGSFT
Bilinx™ communication interface box and software
Recommended lenses Varifocal lenses: • LTC 3264/30 • LTC 3274/40 • LTC 3364/21 • LTC 3364/31 • LTC 3364/40 • LTC 3374/20 Zoom lenses: • LTC 3283/20 • LTC 3384/21
1/2" DC-iris, 1/2" DC-iris, 1/3" DC-iris, 1/3" DC-iris, 1/3" DC-iris, 1/3" DC-iris,
4.5-10mm F1.6-360 7.5-75mm F2.2-360 2.8-6mm F1.4-300 - IR 3.5-8mm F1.4-300 - IR 2.8-12mm F1.4-360 5-50mm F1.4-185
1/2" Video iris, 8-48mm F1.4-360 1/3" DC-iris, 6-60mm F1.4-360
Bosch Security Systems | 2003-10 | V0.5
Page 30
DinionXF | Installation Manual
Bosch Security Systems | 2003-10 | V0.5
EN | 30
Page 31
Bosch Sicherheitssysteme GmbH Ludwig-Bölkow-Allee 85521 Ottobrunn Germany www.bosch-sicherheitssysteme.de
© 2003 Bosch Security Systems B.V. Subject to change. Printed in Portugal. 3122 165 23051
Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven The Netherlands www.boschsecuritysystems.com