Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 4

DinionXF: LTC 0610 & LTC 0485 Series Cameras Installation Instructions, pages 25 to 31

Pages 25 to 31 of 31

The original document is the PDF (302 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Bosch LTC0485

Page 25

DinionXF | Installation Manual

EN | 25

Install I/O --> Alarm submenu Function

Selection

ACTIVE

NONE, HIGH, LOW Selects active_HIGH or active_LOW for the alarm input connector. Select NONE to disable alarm switching.

ACTION

NONE, MODE1, MODE2, MODE3

Selects the operating mode of the camera upon switching the alarm input.

ALARM OUT

VMD, REMOTE

Select VMD to close the output relay upon VMD alarms. Select REMOTE to make the output relay available to remote communication devices.

EXIT

Description

Return to the I/O menu

Install sync submenu Function

Selection

Description

SYNC

INTERNAL, LINE LOCK, HV LOCK, GENLOCK

Select INTERNAL for free running camera operation, select LINE LOCK to lock to the power supply frequency, select HV LOCK to lock to the signal supplied to the external sync input, select GENLOCK to lock the subcarrier as well.

DETECTED SYNC

Shows the actual sync mode used by the camera.

VPHASE

0, 2, … 358

Adjusts the vertical phase offset (when in LINE LOCK mode and a valid power supply frequency is detected).

HPHASE

-25, …, 0, … +125

Adjust the horizontal phase offset (when in EXT lock mode and a valid input signal is detected)

SUB PHASE

0, 2, … 358

Adjusts the sub-carrier phase offset (when in EXT LOCK mode and a valid sub-carrier is detected).

EXIT

Return to the INSTALL menu

Note VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal.

Bosch Security Systems | 2003-10 | V0.5

Page 26

DinionXF | Installation Manual

EN | 26

Install ID submenu Function

Selection

CAMERA ID

ID POS

Description Enter a 16 character camera name string. Use LEFT/RIGHT to change position in the string, use UP/DOWN to select the character. Use SELECT to exit the string edit screen.

OFF, TOP, BOT

EXIT

Select TOP to display the camera ID in the upper left corner; select BOT for the lower left corner. The ID string is not displayed when the OSD menus are open. Return to the INSTALL menu

Defaults submenu Function

Selection

Description

ALL DEFAULTS

Select to restore the factory defaults. A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.

EXIT

Return to MODE menu

Camera Control Communication This camera is equipped with a coaxial communications transceiver. In combination with VP-CFGSFT, the camera can be adjusted from the headend side of the coaxial cable. All menus can be accessed remotely giving full control of the camera. With this communication it is also possible to disable the local keys on the camera. To avoid loss of communication on an installed camera, the COMMUNICATION ON/OFF selection is NOT available while using remote control. This function can only be accessed with the camera buttons.

Bosch Security Systems | 2003-10 | V0.5

Page 27

DinionXF | Installation Manual

EN | 27

Technical specification 1/2" CCD versions Type number

LTC 0610/11

LTC 0610/21

LTC 0610/51

LTC 0610/61

Standard

PAL

NTSC

PAL

NTSC

Active pixels

752x582

768x492

752x582

768x492

Rated supply voltage

24 VAC or 12 VDC 12-28 VAC (50/60 Hz) 12-36 VDC

Min illumination

0.18 lx 0.08 lx with NightSense

230 VAC 50Hz, (/50) 110 VAC 60Hz, (/60) Range: 100-230 VAC ±10% 50/60Hz

1/3" CCD versions Type number

LTC 0485/11

LTC 0485/21

LTC 0485/51

LTC 0485/61

Standard

PAL

NTSC

PAL

NTSC

Active pixels

752x582

768x492

752x582

768x492

Rated supply voltage

24 VAC or 12 VDC 12-28 VAC (50/60 Hz) 12-36 VDC

Min illumination

< 0.24 lux < 0.1 lux (with Nightsense)

230 VAC 50Hz, (/50) 110 VAC 60Hz, (/60) Range: 100-230 VAC ±10% 50/60Hz

All versions Imager

Interline CCD

Resolution

540 TVL

SNR

> 50 dB

Video output

1 Vpp, 75 Ohm

Y/C output

Y: 1 Vpp C: 0.3 Vpp

Synchronization

Internal or HV-lock or Genlock or Line Lock selectable

Shutter

AES (1/60 (1/50) to 1/100000), Flickerless, Fixed selectable

Bosch Security Systems | 2003-10 | V0.5

Page 28

DinionXF | Installation Manual

EN | 28

All versions NightSense

On, Off, Auto

Sens Up

Adjustable from OFF to 10x

Auto black

On, Off selectable

AGC

AGC on or off (0 dB) selectable. Maximum level selectable upto 28 dB

XF-DYN

Automatic dynamic range enhancement level selectable

DNR

Automatic noise filtering ON/OFF selectable

Contour

Sharpness enhancement level selectable

BLC

BLC On or Off selectable, with programmable area

White balance

Automatic 2500 - 9000K (with AWB hold mode and manual mode)

Color saturation

Adjustable from monochrome (0%) to 133% color

Lens Mount

C and CS compatible

ALC lens

Video or DC iris auto detect

Power consumption

<5W

Dimensions

58 x 66 x 122 mm (HxWxL) without lens

Weight

450g without lens

Tripod Mount

Bottom (isolated) and Top ¼" 20 UNC

Operating temperature

-20° to 50° C

Controls

OSD with softkey operation

Bosch Security Systems | 2003-10 | V0.5

Page 29

DinionXF | Installation Manual

EN | 29

Accessories Power transformers • • • •

TC1334 TC120PS TC220PSX-24 TC220PS

120VAC, 60Hz - 24VAC, 30VA 120VAC, 60Hz - 15VDC, 9VA 220-240VAC, 50/60Hz - 24VAC, 30VA 220-240VAC, 50/60Hz - 15VDC, 9VA

Interface box: •

VP-CFGSFT

Bilinx™ communication interface box and software

Recommended lenses Varifocal lenses: • LTC 3264/30 • LTC 3274/40 • LTC 3364/21 • LTC 3364/31 • LTC 3364/40 • LTC 3374/20 Zoom lenses: • LTC 3283/20 • LTC 3384/21

1/2" DC-iris, 1/2" DC-iris, 1/3" DC-iris, 1/3" DC-iris, 1/3" DC-iris, 1/3" DC-iris,

4.5-10mm F1.6-360 7.5-75mm F2.2-360 2.8-6mm F1.4-300 - IR 3.5-8mm F1.4-300 - IR 2.8-12mm F1.4-360 5-50mm F1.4-185

1/2" Video iris, 8-48mm F1.4-360 1/3" DC-iris, 6-60mm F1.4-360

Bosch Security Systems | 2003-10 | V0.5

Page 30

DinionXF | Installation Manual

Bosch Security Systems | 2003-10 | V0.5

EN | 30

Page 31

Bosch Sicherheitssysteme GmbH Ludwig-Bölkow-Allee 85521 Ottobrunn Germany www.bosch-sicherheitssysteme.de

© 2003 Bosch Security Systems B.V. Subject to change. Printed in Portugal. 3122 165 23051

Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven The Netherlands www.boschsecuritysystems.com