Page 45
Page 46
Download/Install ActiveSync
Connect to a PC Via ActiveSync
For best results, the cable should not exceed six feet in length for communications at 115200 baud. The serial cable is wired symmetrically - either end of the cable can be connected to the TREQ-M4 (assuming the connectors match). Connect one end of the serial cable to COM5 on the TREQ-M4. COM5 is available via the USB-to-serial converter. Connect the other end of the serial cable to a free port on the PC. If possible, note the name of the port you use (e.g., COM1, COM2, etc.). Refer to Figure 20, “ActiveSync Connections.”
Figure 20 ActiveSync Connections NOTE
☞
The USB extension cable (item 2 in Figure 20) is not strictly required, although it makes the USB-to-serial adapter/TREQ-M4 connection more convenient.
5.3 Download/Install ActiveSync Download ActiveSync from the Microsoft website and install it on your PC as follows. 1. On your PC, open your Web browser, and navigate to the Microsoft Download Center at http://www.microsoft.com/downloads/Search.aspx?displaylang=en.
36
TREQ-M4 Mobile Data Terminal
Page 47
Connect to a PC Via ActiveSync
Set the TREQ-M4 Baud Rate
2. Type ActiveSync in the search box and begin the search. 3. ActiveSync 4.2 and 4.5 are the two latest versions as of January 2009. Both will work with the TREQ-M4. Follow the appropriate link and download the desired version. 4. Install ActiveSync on your PC by executing the downloaded installer file or executable and following the instructions. 5. When the installation is finished, ActiveSync automatically launches the “Get Connected” wizard that will search the PC’s serial ports for a connection. If you are not ready to connect to the TREQ-M4, cancel this option.
5.4 Set the TREQ-M4 Baud Rate The baud rate is the rate at which data is sent between the PC and the TREQ-M4. Normally, you will want to set the baud rate to the highest rate supported by your hardware and cable length (see section 5.2, “Connect the Serial Cable” for cable length restrictions). When connected, ActiveSync identifies the baud rate used by the TREQ-M4. The default baud rate for the TREQ-M4 ports is 115200 bps. NOTE
☞
If you have communication problems with an ActiveSync connection, try selecting a slower baud rate. To verify or change the baud rate for the TREQ-M4, do the following on the TREQ-M4. 1. Tap [Start] to display the Start menu, then tap Settings and Network & Dial-up Connections. The Network Connections dialog box is displayed. 2. Tap USB COM5. Select File, Properties from the menu. 3. Tap [Configure]. 4. To change the baud rate, tap the down arrow to display a list of possible settings, and tap the baud rate that you want to use.
5.5 Connect the PC and TREQ-M4 With the cable connected (see section 5.2, “Connect the Serial Cable”) and ActiveSync installed on your PC (see section 5.3, “Download/Install ActiveSync”), do the following to establish a connection between the PC and the TREQ-M4. 1. On your PC, start ActiveSync. 2. Open the File menu, and select Get Connected, or select Connection Settings and then click [Connect].
TREQ-M4 Mobile Data Terminal
37
Page 48
Connect the PC and TREQ-M4
Connect to a PC Via ActiveSync
3. Click [Next]. The TREQ-M4 automatically responds to the PC’s ActiveSync connection request. (See Figure 21, “ActiveSync, Get Connected.”) The first time you connect, the PC scans all available serial ports for the ActiveSync connection, which can take some time. For this reason, the TREQ-M4 or the PC may time out before the connection is found. It is typical to have to re-run one or both ActiveSync programs a few times before they find each other. This is especially true if your PC has several serial ports. Once ActiveSync identifies the port, all future connections will occur quickly.
Figure 21 ActiveSync, Get Connected NOTE
☞
If you know to which serial port on the PC the TREQ-M4 is connected, you can select the port in ActiveSync on the PC and save the scanning time. Refer to section 5.5.1, “Select the COM Port Manually.” When the “Connecting to Host” message appears on the TREQ-M4, the ActiveSync window on the PC displays “Connecting.....” 4. When the ActiveSync connection is established, the PC displays a window titled “New Partnership” (see Figure 22, “ActiveSync Partnership”). Typically, you should select No and then click [Next].
38
TREQ-M4 Mobile Data Terminal
Page 49
Connect to a PC Via ActiveSync
Connect the PC and TREQ-M4
Figure 22 ActiveSync Partnership The ActiveSync window then displays “Connected” (see Figure 23, “ActiveSync, Connected”).
Figure 23 ActiveSync, Connected 5. You can now browse the TREQ-M4 file system by selecting the Explore icon or the Explore option on the PC’s ActiveSync File menu (see Figure 24, “ActiveSync, Explore Device”).
TREQ-M4 Mobile Data Terminal
39
Page 50
Connect the PC and TREQ-M4
Connect to a PC Via ActiveSync
Figure 24 ActiveSync, Explore Device
5.5.1
Select the COM Port Manually You can save scanning time during the initial connection if you know to which serial port on the PC the TREQ-M4 is connected. Do the following to select the port. 1. In the ActiveSync program on the PC, select the Connection Settings option on the File menu (see Figure 25, “ActiveSync, Connection Settings”).
Figure 25 ActiveSync, Connection Settings 2. Enable the “Allow connections to one of the following:” option, and select the appropriate COM port. 3. Tap [OK] to save the settings.