Page 21
CHAPTER 3
GETTING STARTED 3.1 Power On/Off/Reset 3.1.1
Turn On the TREQ-M4 To turn on the TREQ-M4, attach the integral cable connector to a power source. The TREQ-M4 boots and loads the operating system, as shown below.
Figure 3 Windows CE Desktop Icons for software your company has installed may be displayed next to those shown above. To use the TREQ-M4, press the keys on the TREQ-M4 frame, or tap the touch keys on the touch screen. Refer to section 3.2, “Touch Screen” for information on using the touch screen. Refer to section 3.3, “Function Keys” for information on using the function keys.
3.1.2
Turn Off the TREQ-M4 You can use one of three methods to turn off the TREQ-M4, as follows:
• Hold down the bottom-most (fourth from the top) keypad key for five seconds. Press the same key again to turn it back on.
• Disconnect the integral cable from the power source. Reconnect the cable to the power source to power the unit back on.
TREQ-M4 Mobile Data Terminal
11
Page 22
Touch Screen
Getting Started
• If you have a Developer's Kit with a Break Out Box, set the power switch on the Break Out Box to the “off” position. Set it to the “on” position to power the unit back on. When the TREQ-M4 is powered off, information in the Windows CE registry and any data stored on the internal flash hard-disk (\HardDisk) is retained. However, the Windows CE file system root folder is RAM-based and will be lost. Consequently, any information that must be retained must be stored under the \HardDisk and \USBHardDisk folders. To avoid losing data, make sure you close any open applications and back up data to a persistent storage location before powering off the TREQ-M4. Corruption will occur if data is being written to files located on \HardDisk or \USBHardDisk during a loss of power.
3.1.3
Reset the TREQ-M4 Reset the TREQ-M4 if the operating system stops operating. Press and hold the bottom-most (fourth from the top) keypad key for five seconds. Release the key, and momentarily press it again to boot. If the TREQ-M4 does not restart, verify that the integral cable is fully seated and has power.
3.2 Touch Screen 3.2.1 Touch Screen Care Use only your fingertip or a stylus to tap the touch screen. Other objects (such as either end of a pencil) will damage the transparent film or plastic backing. Use a light touch, just hard enough for the screen to respond. To clean the touch screen, moisten a soft cloth with water or a window cleaner such as Windex®. Then gently wipe the screen clean with the cloth. Do not spray liquid directly on the touch screen.
3.2.2
Touch Screen Use When you tap or press on the TREQ-M4 touch screen, it responds with a clicking sound. Tap on an icon (e.g., “My Device”) to highlight and select the item. Tap twice (double-tap) on an icon to open the item or start the program. Tap [Start] to display the Windows Start menu, which gives you access to all system functions and programs. Any of the menu options with right-pointing arrows will open a sub-menu. Tap once on an option to display its sub-menu. For example, tap Programs, and a sub-menu of all user programs loaded on your TREQ-M4 is displayed. Tap the screen background to close the Start menu, or tap [Start] again.
NOTE
12
☞
If you are having problems selecting functions on the touch screen, you may need to recalibrate the touch screen. Refer to section 4.1.1.2, “Recalibrate” on page 18 for information.
TREQ-M4 Mobile Data Terminal
Page 23
Getting Started
Function Keys
3.3 Function Keys The TREQ-M4 has four function keys, as shown below.
Figure 4 TREQ-M4 Function Keys The function keys are mapped by default to the keyboard keys F1, F2, F3, and ESC (top to bottom). The bottom-most key can be used to power off or reset the TREQ-M4. Refer to section 3.1.2, “Turn Off the TREQ-M4” and section 3.1.3, “Reset the TREQ-M4.” The keys may be mapped to any keyboard or mouse (cursor control) function. In addition, keys may be mapped to launch applications or initiate a sequence of actions. You can modify the Windows CE registry or write a program to set the keypad mappings. Refer to section 6.3.1, “Keypad” for more details. The function keys may be configured for a normal and a shifted state. The shifted state provides a mechanism to quickly switch between two sets of mappings. The keypad state can be changed programmatically (refer to section 6.3.1 for details on the keypad driver API). The \HardDisk\bin\KeyShiftCE.exe utility is a sample application that switches the keypad state. The function keys are mapped by default in the shifted state to launch Windows Explorer (topmost key) and the keyboard keys “b” through “d.” Autorepeat is disabled by default for these keys.
TREQ-M4 Mobile Data Terminal
13
Page 24
System Settings
Getting Started
3.4 System Settings To access the system settings (calibration, double-click (double-tap), backlight, keyboard, TREQ panel, date/time, volume and sounds, and more) through the Windows CE control panel, select Start, Settings, and Control Panel as shown below.
Figure 5 Windows CE Start Menu Refer to Chapter 4, “System Settings” for information on the control panel settings.
3.5 Install Third-Party or Custom Software You can install any software application on the TREQ-M4 that is compatible with Windows CE, has been compiled for the ARM platform, and does not exceed the system requirements of your TREQ-M4. You can download it from a network or the Internet (depending on your interface setup), or you can use ActiveSync (refer to Chapter 5, “Connect to a PC Via ActiveSync” for information). Third-party software applications are typically packaged in a Microsoft CAB file format, which are then packaged in a PC-side installer executable or Microsoft MSI file. The bare CAB files can be copied to the TREQ-M4 and installed manually, or the MSI file can be executed on a PC and the included CAB file downloaded and installed via ActiveSync. For applications installed via ActiveSync, execute the downloaded installation file from Windows Explorer on a PC. The application installer should automatically launch ActiveSync, download a CAB file to the TREQ-M4, and initiate installation of the CAB file on the TREQ-M4. A CAB file can be downloaded directly to the TREQ-M4 without ActiveSync. For this type of installation, double-tap the CAB file from a Windows Explorer session on the TREQ-M4 to initiate the installation process.
14
TREQ-M4 Mobile Data Terminal
Page 25
Getting Started
Run Third-Party Software
NOTE
☞
It is recommended that the destination of the CAB file installation files be in the HardDisk directory because that storage location is on the internal persistent storage, otherwise the installation will be lost after a power cycle. See section 3.1.2, “Turn Off the TREQ-M4” for more details.
NOTE
☞
See section 10.1.1, “Operating System” on page 81 for information about UpgradeCE.exe, a Beijer Electronics package manager program that can be used similarly to the Windows CE CAB installer. UpgradeCE.exe software application packages and settings are retained even after system firmware upgrades.
3.6 Run Third-Party Software Third-party or custom software installed on the TREQ-M4 may be listed in the Start menu under “Programs.” Tap a program name in the menu to run the program. A program may also have an icon on the desktop. If so, double-tap the icon to start the program.
3.7 Build Your Own Software You can write your own applications and program your own key functions (for the function keys on the TREQ-M4) using Microsoft programming tools. Refer to Chapter 6, “Application Development” for more information.
TREQ-M4 Mobile Data Terminal
15
Page 26
Build Your Own Software
Getting Started
Notes
16
TREQ-M4 Mobile Data Terminal