CHAPTER 3. QTERM-R55 HARDWARE 3.1

QTERM-R55 Handheld Terminal

The dimensions of the QTERM-R55 handheld terminal are shown in Figure 3-1. This figure also shows the standard keypad legend for the keys on the 40-key keypad. The housing is made from impact-resistant ABS and is colored black. The housing is not waterproof, but it can be subjected to moderate rain or splash without harm. The QTERM-R55 handheld terminal uses a 6-pin modular jack, exiting from the bottom of the housing. If desired, the modular jack can easily be switched to exit from the top of the QTERM-R55 housing. The pin assignments for the connectors for each of the available interfaces are shown in Table 3-2. Figure 3-2 shows the pin numbering for the connectors used on the 105.9

QTERM-R55. For reference, Table 3-1 shows the pin assignments used by the COM ports on PC-style computers for both DB25 and DB9 connectors.

3.2

QTERM-R55 Panel-Mount Terminal

The panel-mount QTERM-R55 is mounted directly onto your instrument or enclosure. Figure 3-3 shows the dimensions of the panel-mount QTERM-R55 along with the standard keypad legend for the 24-key keypad. The QTERM-R55 is mounted to the panel by placing the terminal into the panel cutout and attaching the rear shell behind the panel with the four self-tapping screws. A mounting gasket is provided in order to seal the front edge of the terminal. Figure 3-4 shows the assembly diagram along with the panel cutout dimensions required for mounting.

33.2

QTERM- R55

F1

F2

F3

F4

A F

B G

C H

D I

E J

K P

L Q

M R

N S

O T

U X

V Y

W Z

? /

-+

( #

SHIFT

)

*

F5

1

2

3

4

5

6

7

8

9

0

SPACE ENTER

ESC DEL

88.2

194.9

29.2

Handheld

Figure 3-1. Dimensions of the QTERM-R55 Handheld Version.

Figure 3-2. QTERM Connector Pin Assignments.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 28

18

QTERM-R55 User's Manual

Table 3-1. Pin Assignments for PC-Style COM Ports. COM Ports with Male DB25 Connectors Pin

COM Ports with Male DB9 Connectors

Function

Pin

Function

2

PC transmit

1

CD *

3

PC receive

2

PC receive

4

RTS *

3

PC transmit

5

CTS *

4

DTR *

6

DSR *

5 ground

7 ground

6

DSR *

8

CD *

7

RTS *

20

DTR *

8

CTS *

22

RI *

9

RI *

*These lines normally can be left unconnected. Some PCs may require that one or more of them be pulled to 5 volts through a pullup resistor (about 300 ohms)

3.3

QTERM-R55 Large Character PanelMount Terminal

The dimensions of the QTERM-R55 large character panelmount terminal are shown in Figure 3-6. This terminal is available with a 24-key or a 40-key keypad.

QTERM - R55

The housing is made from rugged glass-fiber filled nylon plastic and is colored black. The housing is not waterproof, but it can be subjected to moderate rain or splash without harm. F1

F2

F3

F4

+

--

#

*

> ESC

1

2

3

<

4

5

6

7

8

9

DEL

0

Figure 3-3. Dimensions of the QTERM-R55 Panel Mount Version. Connection to the panel-mount QTERM-R55 is made via a 6-pin 2 mm pitch header which is located on the PCB as shown in Figure 3-5 (standard output).

The QTERM-R55 is mounted directly onto your instrument or enclosure panel. Figure 3-7 shows the mounting cutout required to install the terminal.The QTERM-R55 is mounted to the panel via four angle brackets that attach to the terminal with self-tapping screws that insert from the rear of the bracket and screw into the bosses on the QTERM-R55 enclosure. These brackets are designed so they can be attached before inserting the terminal into the panel. Once the brackets have been installed, the terminal is inserted into the panel and the brackets are slid outward. Then the screws are tightened and the brackets hold the terminal in place. Screws and brackets are included with the QTERM-R55; these are usable with panels up to about 10 mm thick. A gasket is provided to seal the outside edges of the terminal where it presses against the panel. Connection to the large character panel-mount QTERM-R55 is made via the DB9 connector which is accessible on the back of the terminal. The connector pin numbering is shown in Table 3-2.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 29

QTERM-R55 User's Manual

19

Table 3-2. QTERM Pin Assignments QTERM EIA-232/ 5VB Function

QTERM EIA-422 Function

QTERM EIA-485 Function

3 receive

+receive

RTx-

2

6

RTS*

-receive

RTx+

3

3

2 transmit

+transmit no connect

4

4

1

CTS*

-transmit no connect

5

5

9 power power power

6

6

5 ground ground ground

Handheld 6-pin Modular

6x1 2 mm

DB9 Female

1

1

2

*if the hardware flow control option is enabled

3.4

Interfaces

3.4.1

EIA-232 Interface

With proper cables and good grounding, the EIA-232 interface on the QTERM-R55 can communicate up to about 15 meters. Handshaking between the host computer and the QTERMR55 is optional. This is done using software flow control (XON/XOFF) or the EIA-232 modem-control lines (such as RTS and CTS). Note the non-standard pinout for the RTS and CTS lines on the DB9 connector. 3.4.2

EIA-422 Interface

With proper cables and grounding, the EIA-422 interface can communicate up to a distance of about 1,000 meters. The EIA-422 version of the QTERM-R55 uses four communication lines and two power lines.

Panel Cutout

Figure 3-4. QTERM-R55 Assembly and Panel Cutout Dimensions.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 30

20

QTERM-R55 User's Manual

R55 CPU PCB

Auxilliary Output 2mm 1 2 3 4 5 6

232 Function Rx RTS Tx CTS +5VDC Out Ground

422 Function Rx+ RxTx+ Tx+5VDC Out Ground

Standard Output

485 Function RTxRTx+ +5VDC Out Ground

2mm 1 2 3 4 5 6

232 Function Rx RTS Tx CTS +8-32VDC In Ground

422 Function Rx+ RxTx+ Tx+8-32VDC In Ground

485 Function RTxRTx+ +8-32VDC In Ground

Battery Back 2mm 1 2 3 4 5 6

Function Ground N/C +5VDC Out BATSLP LowBAT Ground

Output Wiring Detail

Figure 3-5. QTERM-R55 Panel Mount Output Wiring 3.4.3

EIA-485 Interface

The EIA-485 interface is similar to EIA-422, but was designed as a half-duplex multidrop interface. With proper cabling and termination, up to 32 EIA-485 devices can be connected across a cable of up to 1000 meters in length. The EIA-485 interface on the QTERM-R55 uses two communication lines and two power lines.

31 197

7

Auxillary Port Mounting Bracket 1 of 4

184

For discrete wires

23

DB9

Optional E-Stop Switch

Front View

21 Side View

Gasket is included

Back View

Figure 3-6. Dimensions of the QTERM-R55 Large Character Panel-Mount Terminal.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 31

QTERM-R55 User's Manual

21 has responded or the timeout period for the slave response has expired.

183

3)

4 mm max radius 4 places

3.5 Cut Out This Hole

170

User's Panel

Figure 3-7. Cutout Dimensions for the QTERMR55 Large Character Panel-Mount Terminal. The EIA-485 interface uses intelligent electronics to control the direction of the interface (transmit vs. receive). The interface is held in receive mode until the user application transmits data. The circuit senses the beginning of the transmission and immediately switches to transmit mode until the transmission is ended. At that time, the interface reverts to receive mode until another transmission is requested. All of this is handled by the interface electronics, and is completely transparent to the user application. This can simplify the task of writing software for the EIA-485 interface, because the application does not need to directly control the direction of the interface. The QTERM-R55 operating system does not specify or enforce any protocol or link layer functions on the EIA-485 interface. This must be provided by the user application. Most EIA-485 networks use some form of master-slave protocol to control network traffic. This is accomplished in software by adhering to a few simple rules: 1)

2)

Slave devices must never initiate a transmission unless they are queried by the master. The slave then needs to respond within a certain time period. Master devices may initiate transmissions to slaves, but after doing so the master should wait (and not transmit again) until the slave

If broadcast queries (which require a response from multiple slaves) must be supported, the slaves should respond sequentially or otherwise resolve the response traffic to avoid contention.

LCD Display

The QTERM-R55 display is a 4-line by 20-character supertwist LCD unit. The entire 128-byte ASCII character set can be displayed; also, many Greek letters, katakana characters, non-English alphabetic characters and math symbols can also be displayed. Appendix B. is a chart which shows how the QTERM-R55 will display each 8-bit value. Note that the ASCII portion of the chart (the first 128 characters) is similar, but not identical, to the true ASCII chart shown in Appendix A. If you ordered the backlight, the qaBASIC commands listed in Chapter 2 will allow you to turn the backlight on and off. Without the backlight, these commands have no effect.

3.6

Keypad

The QTERM-R55 is available with a 24-key or a 40-key keypad. The Power-On Setup menus allow you to control both key click (on or off) and key repeat (on or off, delay and rate).

3.7

Other Options

3.7.1

Speaker Option

The QTERM-R55 includes an audio speaker which is used for key beeps and for beeping in response to a beep or bell command. 3.7.2

Real-Time Clock Option

If you order the real-time clock option, the QTERM-R55 includes hardware support for the date$ and time$ qaBASIC commands. 3.7.3

Switching Regulator

The standard QTERM-R55 uses a switching regulator which allows the terminal to be powered from a 8-volt to 32-volt DC source.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 32

22

QTERM-R55 User's Manual

3.8

QTERM Specifications

3.8.2

3.8.1

Environmental Characteristics

Typical current consumption is listed in Table 3-4.

Environmental and power specifications are listed in Table 3-3. Table 3-3. Environmental and Power Specifications Parameter

Electrical Characteristics

Table 3-4. QTERM-R55 Current Consumption. Version

Ireg (mA) @ 8V

Ireg (mA) @ 32V

EIA-232

88

33

Add for backlight

30

9

Add for each LED

4

2

Limits

Standard/Backlit Display usable temperature range

-10 to 60 °C

Wide- temperature Display usable temperature range

-20 to 70 °C

Storage temperature, all components

-40 to 85 °C

Maximum humidity range, all components

0 to 95%, non-condensing

Operating voltage range

8 to 32 volts DC

Battery Back Option Battery life Battery life, backlight on

60 hours 24 hours

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770