Page 111
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________ Local Modem Setup : Rings to Auto-Answer 2 Modem Connectivity Time-out is Disabled Login Setup: Login Password is BTA Strike any Key to Continue Port
Device Name
Baud Rate
Word Size
Stop Bits
Parity
Xon / Xoff Xmit
Recv
1
Host EIA-232
9600
8
1
None
Off
Off
2
Host MODEM
57.6K
8
1
None
Off
Off
Strike any Key to Continue
SERIAL PORT CONFIGURATION Type “2” (in the configuration main menu) and <cr> to change the serial port configuration. The module will respond: Enter Host Device Number (1-2): 1 Module 1 Serial Port Configuration : Port
Device Name
Baud Rate
Word Size
Stop Bits
Parity
1
Device A
9600
8
1
None
Xon / Xoff Xmit
Recv
Off
Off
Exit/Save......1 Set Stop Bits.....4 Set Baud Rate..2 Set Parity........5 Set Word Size..3 Set Xon/Xoff......6 Enter Request :
You can now reconfigure the V93A EIA-232 port by sending the appropriate option (1 to 6) from the menu. For example, to change the baud rate to 115.2K, send "2" (Set Baud Rate). The V93A will respond with: 1 For 300 2 For 600 3 For 1200 4 For 2400 5 For 4800 6 For 9600 7 For 19200 8 For 38400 9 For 57.6K A For 76.8K B For 115.2K Enter Request :
99
Page 112
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
Send "B" for 115.2K baud rate. The V93A will respond with the reconfigured status of the port as follows: Module 1 Serial Port Configuration : Port
Device Name
Baud Rate
Word Size
Stop Bits
Parity
1
Device A
115.2K
8
1
None
Set Stop Bits Set Parity Set Xon/Xoff
4 5 6
Exit/Save Set Baud Rate Set Word Size
1 2 3
Xon / Xoff Xmit
Recv
Off
Off
Enter Request :
You can now select other options from the menu. If there are no other changes, send "1" (Exit/Save) and the V93A will respond with: Save Changes Permanently ? (Y/N) :
If you type "Y", the new configuration for the selected port is stored permanently in nonvolatile memory until. If you type “N” the V93A will return to the main configuration menu. NOTE: If you are configuring the V93A from the EIA-232 port, the V93A will respond with: Change Device to NEW Configuration Before Answering This Request.
IMPORTANT: This message reminds you to change the serial port configuration of the host device now. If they do not match, the V93A will be unable to interpret the next command. If this happens, cycle power on the MSeries DAC and reconfigure the unit. PORT DEVICE NAME Type “3” (in the configuration main menu) and <cr> to change the port device name. The module will respond: Module 1 Serial Port Configuration :
100
Port
Device Name
Baud Rate
Word Size
Stop Bits
Parity
1
Device D
9600
8
1
None
Xon / Xoff Xmit
Recv
Off
Off
Page 113
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________ Enter Port Device Name (Max. 16 characters): or ENTER for no change ...........:
Enter the desired Port Device Name up to 16 characters. For example, if you type "PORT 4" followed by <cr>, the module will respond with: Module 1 Serial Port Configuration : Port
1
Device Name
PORT 4
Baud Rate 9600
Word Size 8
Stop Bits 1
Parity
None
Xon / Xoff Xmit
Recv
Off
Off
Enter Port Device Name (Max. 16 characters): or ENTER for no change ...........:
If the Port Device Name is satisfactory, type <cr>. The V93A will return to the main configuration menu. NOTE: If the V93A Connect Port ID Echo feature is programmed for Use Device Name, the message sent to the host device when the host selects a V74/V75 peripheral port will be the Device Name shown in the menu above. PORT SELECT CODE Type “4” (in the configuration main menu) and <cr> to change the port select code. The module will respond: Port Select Code is
$BT
Enter Port Select Code (Max. 8 characters): or ENTER for no change:
Type the desired Port Select Code followed by <cr>. For example, if you type #PORT followed by <cr>, the V93A will respond with: Port Select Code is
#PORT
Enter Port Select Code (Max. 8 characters): or ENTER for no change:
If no additional change is desired, type "ENTER". The V93A will store the new Port Select Code permanently into non-volatile memory and return to the main configuration menu .
101
Page 114
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
ATTENTION CHARACTER Type “5” (in the configuration main menu) and <cr> to change the attention character. The module will respond: Attention Character is ; Change It ? (Y/N) :
Type "Y" to change the Attention Character. The V93A will respond with: Enter Attention Character :
Type the desired Attention Character. For example, if you type "%", the V93A will respond with Attention Character is % Change It ? (Y/N) :
Type "N" if no additional change is desired. The V93A will store the new Attention Character into non-volatile memory and return to the main configuration menu. DISCONNECT TIME GUARD Type “6” (in the configuration main menu) and <cr> to enable or disable the disconnect time guard. The module will respond: Disconnect Time Guard10:28 AM is Change It? (Y/N):N
Enabled
Type "Y", to toggle the existing state of Disconnect Time Guard10:28 AM or "N" for no change. The V93A will store the selected state of the Disconnect Time Guard into nonvolatile memory and return to the main configuration menu. LOGIN PASSWORD Type “7” (in the configuration main menu) and <cr> to change the password. The module will respond: Login Password Is Change It: (Y/N):
BTA
Type “Y” to enter the new password up to 8 ASCII characters followed by <cr>. For example, if you what to change the Login Password to LOGIN, type "LOGIN" at the prompt. The V93A will respond with: Enter New Password ( 1 - 8 char., CR to end):
102
Page 115
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
If the Login Password is correct, type "N". The V93A will store the new Login Password into non-volatile memory and return to the main configuration menu. LOCAL MODEM SETUP Type “8” (in the configuration main menu) and <cr> to change the local modem setup. The module will respond: Local Modem Setup: Rings to Answer Connectivity Time-out Exit Enter Request :
1 2 X
Type the number corresponding to your desired choice. For example, if you type “1” (Rings to Answer), the V93A will respond with: Rings to Auto-Answer Change It ? (Y/N) :
1
Type “Y” to change the Number Rings to Auto-Answer setting. The V93A will respond: Enter Number of Rings to Auto-Answer (1 to 4) :
The V93A will store the Number of Rings to Auto-Answer in non-volatile memory and return to the main configuration menu. By responding to the message in the Local Modem Setup menu with "2" Connectivity Time-out The V93A will respond with: Enter Request : 2 Modem Connectivity Time-out is 5 minutes Change It ? (Y/N) :
This time-out can be programmed from 5 to 255 minutes, or 0 (=disable). The timer is started when the modem goes off-hook (DCD goes high), and the modem will return to “on hook” after the time-out has expired. The factory default is 0 (disabled). EXIT Type “X” (in the configuration main menu) and <cr> to exit the configuration menu.
103
Page 116
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
ECHO MODE The V93A can be placed into echo mode by sending seven semicolons (;) in succession. While in echo mode, the V93A will echo all characters received by the connected device back to that device. Echo mode is terminated by placing an I/O module into command mode ($BTm<cr> where m is the desired module number. Echo Mode would be used only when the ASCII string method of port selection is used. If the Menu Mode(Attention character method) of port selection is used the Echo Mode is not required. RING DETECT RESET The V93A has a Ring Detect Reset feature that will automatically cycle power on the M Series unit if an incoming call is detected and not answered within seventy seconds. The Ring Detect Reset feature is enabled by connecting a straight 2-wire or 4-wire cable between the auxiliary 4-pin modular connector on the V93A and the DIAL service modem port on the M Series chassis. MODEM LED INDICATORS The V93A has five LEDs on the rear panel that indicate the modem status: TD, RD, CD, MR, and CX. These LEDs are described below. LED
Description
TD
Transmit Data: Indicates the modem is transmitting data.
RD
Receive Data: Indicates the modem is receiving data.
CD
Carrier Detect: Indicates a valid carrier tone has been detected.
MR
Modem Ready: Indicates the modem is ready to communicate.
CX
Connection: Indicates the V93A has a connection to the main board, to a module, or to an individual channel or port.
104
Page 117
M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________
BASE UNIT AND MODULE OPERATION BASE UNIT USER-PROGRAMMABLE FEATURES You can program the year, month, day, hours, minute, and second for the main unit. All modules derive their time from the base unit's time-of-day clock. You can also program the Unit Number from 1 to 30. BASE UNIT BASIC OPERATION The M Series base unit acts as a switch between the host control module(s) and the I/O modules. The base unit also allows configuration for the entire M Series system from the service port or service modem. The base unit contains the system power supply (M8 & M16 only), LEDs, a service port, an optional service modem, a main unit PC board with system control firmware and time-of-day clock (optional on M3 & M4), multiple expansion slots for host control modules and I/O modules, a power LED, and a power control switch. When the base unit is powered up, the power LED illuminates. The base unit conducts a self test during which the LEDs cycle from the lowest to the highest, stopping on the CX LED. After a brief moment, several LEDs will light to indicate the module slots that are currently occupied. These will extinguish and all LEDs will sequence from the CX LED to the lowest LED. If all modules are operating properly, all LEDs will extinguish. Any module that is not operating properly will be indicated by the light for that number module coming on and remaining on. NOTE: The CX LED may stay on after the self-test if the service port is connected to a terminal. Once all module LEDs are out, the unit is in operations mode and ready to accept commands and/or data. The commands consist of data commands, dynamic configuration commands, and menu-driven configuration commands. Data and dynamic configuration commands are issued by a host control module. Menu-driven configuration commands are issued by a host control module, the service port, or the service modem. NOTE: Any modules (except host modules) that are not operating properly will most likely not affect the other modules. However, the equipment being tested, switched, or monitored by the defective module will be inaccessible until the problem is resolved. BASE UNIT DATA COMMANDS
105
Page 118
M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________
This section addresses the data commands supported by the base unit itself. Refer to the appropriate sections for the host control module and the various I/O modules for a description of data commands supported by those M Series components. The various configuration commands supported by the base unit are described in Section 6 (Base Unit Configuration). The base unit supports data commands: Read Time, Reset and Echo Mode. BASE UNIT READ TIME (RT) COMMAND The Read Time (RT) command is used to obtain the current time and date from the base unit's time-of-day clock. A user connected to a V71 host module or a user connected to the service port or service modem can issue the Read Time command. The user must select the base unit prior to sending the Read Time command. A user selects the base unit by sending the port select code, "0", and <cr>. For example, if using the default port select code, the user would send $BT0<cr> (use $BAYTECH0<cr> with M4 and M8 DAC). The Read Time command has the following format:
RT<cr>.
When the RT<cr> command is issued, the base unit responds with the current time and date as follows: HH:MM:SS,MM/DD/YY, where HH is the hour, the first MM is the minute, SS is the second, the second MM is the month, DD is the day, and YY is the year. BASE UNIT RESET COMMAND The Reset command is used to instruct the entire M Series system to do a software reset. The main unit conducts a self-test and the system resumes the operation mode. The Reset command has the following format: $BTRESET<cr> ($BAYTECHRESET<cr> on M4 and M8 DAC) .
This command does not affect any saved configuration parameters that have been changed from the default values. ECHO MODE
106
Page 119
M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________
The service modem can be set to an "echo" mode by sending five semicolons(;) in succession from the host terminal. While in echo mode, the service modem will echo back all characters received by the connected terminal. Echo mode is terminated by selecting a specific M-Series module ($BTn<cr> n= 1-16) or a specific peripheral communications port ($BTn,p<cr> n = 1 to 16 and p = 1 to 4. BASE UNIT LED DESCRIPTION All units are equipped with LEDs on the front panel. The green power LED indicates power is applied to the unit. The red module LEDs are used to show connection status. These LEDs are grouped into module numbers (Module 1, Module 2, ..., to Module 16) with each module number having four LEDs (1 to 4). The functionality of the LEDs for a particular module location depends on the type of module installed in that location. When a specific port on a V74, V75 or V87 module is selected by a host module, the LED for the selected port and port 1 of the host module will illuminate. When a host module places an I/O module into command mode, the LED for port 1 of the host will illuminate. When a V74/V75/V87 I/O module is placed into configuration mode by a host module, the service port, or the service modem, all LEDs for the I/O module will illuminate. For example, if a host module selects port 1 of a V74 module, the LED for port 1 of the host module and port 1 of the V74 module will illuminate. There are two LEDs for the service modem (if installed) and a single LED for the EIA-232 service port. An illuminated CX LED indicates the connected terminal has selected the main board or an installed module. When a connection is established between a remote modem and the service modem, the CD LED for the service modem will illuminate. V71 OPERATION V71 USER-PROGRAMMABLE FEATURES User-programmable features for the V71 include the port select code and serial port configuration. These features are programmed by accessing the menu-driven configuration mode from the V71 or service port.
V71 PORT SELECT CODE
107
Page 120
M SERIES DAC BASE UNIT AND MODULE OPERATION ____________________________________________________________________________
The port select code is sent as part of a select sequence by the host terminal to a V71 in order to select specific I/O modules or the main board of the M Series model to issue configuration or data commands. The port select code is a programmable ASCII character string that can range from 1 to 8 characters. The default port select code is $BT. V71 SERIAL PORT CONFIGURATION The V71 translates data for devices using different serial configurations. You can set the baud rate, word size, stop bits, parity and XON/XOFF handshaking for each individual port. In addition, you can select the line interface for the V71. The factory default serial port configuration is 9600 baud rate, 8 bit word size, 1 stop bit, no parity, XON/XOFF handshaking disabled, and EIA-232 line interface. V71 RESET COMMAND The entire M-Series unit can be reset by issuing a reset command to the V71. The reset command consists of the port select code ($BT - default) followed by "RESET" <cr>. For example, if using the default port select code, send $BTRESET <cr> to the V71 to reset the unit. V71 TEST COMMAND A host computer can verify communication with the V71 by sending the port select code ($BT - default), followed by capital "T" and Carriage Return or Line Feed. The V71 will respond with an "ACK" character (06 Hex). For example, if using the default port select code, send $BTT<cr> and the V71 will respond with "ACK" if there is communications between the host terminal and the V71. V71 BASIC OPERATION Once the host computer has been cabled to the V71 and the V71 configured for the desired parameters, the host computer is ready to perform data acquisition and control functions with the various I/O modules. Among the functions you can perform are configuration and data commands. Configuration commands are used to program the features of the various I/O modules and the data commands are typically used to request stored data received from an I/O module. Data commands are also used to instruct certain I/O modules to perform a specific task (e.g., energize or de-energize a relay).
108