For the Axis 221

Page 46

46 AXIS 221 - Unit Connectors

Unit Connectors This section describes the following: • The I/O Terminal connector • Power connections • The RS-232 D-Sub connector

I/O Terminal connector The 10-pin I/O terminal connector provides the interface to a solid state relay output, two digital photo-coupled inputs, RS-485, GND and auxiliary power. The terminal connector is used in applications for e.g. motion detection, event triggering, time lapse recording, alarm notification via e-mail, image storage to FTP locations, etc. • Input - Used for connecting external alarm devices and triggering images for specific alarm-based events. The input is typically connected to a motion detector or any other external security device, and images can be uploaded whenever the detector is activated. Maximum 18VDC is allowed on the input. • Output - This can drive a maximum load of 50VDC or 35VAC at 100mA directly or heavier loads by connecting additional relay circuitry. If the output is used with an external relay, a diode must be connected in parallel with the load for protection against any voltage transients. Caution! Connecting AC to the inputs/outputs will damage the unit. 10-pin I/O Terminal connector (including RS-485) 1 2 3 4 5 6 7 8 9 10

Power connector block RS-232 connector AC AC

GND DC+

Power adapter connector Connect AC power (10-24V) on pins 2 and 3. Connect DC power (7-24V) on pins 1 and 2.

Page 47

AXIS 221 - Unit Connectors I/O terminal connector pinout table Pin

Function

Description

1

Output A

2

Output B

On the external device output terminals (A and B), there is no distinction between positive and negative (+ and -). The terminals use a photocoupler and are electrically isolated from the other internal circuitry. The maximum load should not exceed 100mA and the maximum voltage should be not more than 50VDC or 35VAC.

3

Digital Input 1 Photocoupler Anode (+)

4

Digital Input 1 Photocoupler Cathode (-)

5

Digital Input 2 Photocoupler Anode (+)

6

Digital Input 2 Photocoupler Cathode (-)

Photocoupled Input 1. Electrically isolated from the chassis and connectors, this input can be supplied from an external DC voltage or the DC Power Input/Output on pins 9 (DC+) and 10 (GND). Photocoupled Input 2. As above.

7

RS-485-A (non-inverting)

8

RS-485-B (inverting)

A half-duplex RS-485 interface for controlling auxiliary equipment.

9

DC + Power Output

This can drive the photocoupler inputs or other equipment. The output voltage level is 3.0 V. A maximum current of 100mA can be sourced from the DC output.

10

GND

Ground.

I/O Terminal connector schematic diagram Example schematic diagram of the AXIS 221 terminal connector - showing possible applications.

o1 o

2

Optional Relay Switch o o

Appliance o o o o

Mains Power o3 o o

24V DC Switch, etc.

o4

A RS-485 B o5

+ o6

_ o7 o8

External Device

9 + 10 -

Active Control Device o

47

Page 48

48 AXIS 221 - Unit Connectors

Power connections Power can be supplied to the camera by the following methods: • the supplied power adapter, PS-K, 9W. The center pin is positive (+). • PoE (Power over Ethernet) with power classification Class 2, via the network cable. This will automatically be detected if available via the network. • the power connector block on the rear panel. Power connector block The power connector block supports both AC and DC input power. The DC supply is 7-24V. Connect the negative pole to the GND pin and the positive pole to the DC+ pin. The AC supply is 10-24V. Connect the AC poles to the AC pins. Power connector block pin assignment table. Pin

AC

AC

Function

GND

Ground/DC-

AC/DC+

AC and DC+, power input for mains power to unit

AC

AC power input for mains power to unit

GND

DC+

Schematic Diagram - Power terminal block and power connectors o 3 z

Internal 3.3V z z

Switch Mode Power Supply z z o2 z z

~ z z z

AC

AC/DC+

= o 1 GND/DC-

GND +o -o

Axis Power Supply PS-K 9V max 9W or according to parts list

Page 49

AXIS 221 - Unit Connectors

The RS-232 connector The AXIS 221 provides one 9-pin D-sub connector, providing the physical interface for an RS-232 port, used for connecting accessory equipment. A diagram of the RS-232 connector, complete with pin assignment table, is shown below. Pin

Function

1

CD

2

- RXD

3

- TXD

4

DTR

5

GND

6

DSR

7

RTS

8

CTS

9

RI

1

2 6

3 7

4 8

5 9

49