For the Axiohm TPSK

Page 61

SET PRINT DENSITY Synopsis:

Setting Print density

ASCII

US 1F 31

Hexadecimal Decimal

Limit:

VT 0B 11

N 4E 83

R 52 80

Decimal:

80 ≤ n ≤ 120

Hex:

50 ≤ n ≤ 78

J 4A 69 n n n

This command must be followed by a reset (1D FF).

Note: where n must be a multiple of 5. Description: Set the print density ( energy applied to paper ) in percent relative to nominal energy.

WARNINGS !! Choose a print density setting no higher than necessary to achieve acceptable print density. Failure to observe this rule may result in a printer service call. Failure to observe this rule may void the printer warranty. Consult your Axiohm technical support specialist if you have questions. RESET EEPROM Synopsis:

Reset EEPROM

ASCII Decimal

US 1F 31

Operand:

n = security byte

Hexadecimal

CR 0D 13

C 43 67

L 4C 76 Limit:

E 45 69 n n n n=0

Description: This command will reset the non-volatile memory configuration items to their default values. Note:

This command must be sent while the printer is in its boot-operating mode. Once the configuration parameters are downloaded to the printer using this command, the printer must be reset before they take effect. RESET EEPROM OPERAND DEFINITION n Decimal

Hex

Reset

0

00

Reset EEPROM

TPSK 12 & 24 V User’s Manual

Page 60 / 66

Reference: FDE 31 08 972 Issue Z

Page 62

PRINT TEST FORM Prints the current configuration settings on the receipt. ASCII Hexadecimal Decimal

US t 1F 74 31 116

This command is effective only at the beginning of a line.

JAM SENSOR CALIBRATION Calibrate the Paper Jam opto sensor. This command feeds paper to create a loop when using a cover in production. ASCII Hexadecimal Decimal

GS ; n1 n2 n3 n4 1D 3B n1 n2 n3 n4 29 59 n1 n2 n3 n4

This command must be used for production or maintenance only. Contact a tech support if needed.

TPSK 12 & 24 V User’s Manual

Page 61 / 66

Reference: FDE 31 08 972 Issue Z

Page 63

5.15 Font Download DOWNLOAD FONT Synopsis Syntax Operand

Limit

Returns

Description

Download single byte printer font ASCII: FS L f8 t w h {d} Hex: 1C 4C f8 t w h {d} f: 8 character font name t: font storage Id w: font character width in dots, including inter-character space h: font character height in dots, not including inter-line space d: downloaded data bytes Hex: 0x20 ≤ f ≤ 0x7F 0x30 ≤ t ≤ 0x33 0x01 ≤ w ≤ 0x30 0x01 ≤ h ≤ 0x40 0x00 ≤ d ≤ 0xFF ASCII: OK: ACK Fault: NAK Hex: OK: 0x06 Fault: 0x15 This command will download a single byte font code page to the printer. If the download is successful, an ACK will be returned. If unsuccessful, a NAK will be returned. A font must always be downloaded completely, which corresponds to 224 characters. The font name is used to identify the font. It will be printed on the diagnostics or configuration form. When a downloaded font is to be deleted, the font name is used to identify the font. Two fonts cannot have the same name. Each character is downloaded as rasters, from top to bottom, and for each raster, from leftmost byte to rightmost byte. The storage Id provides the operand for the ‘ESC t n’ (1Bh 74h n) command that will be used to select this code page. Two fonts cannot have the same storage Id.

TPSK 12 & 24 V User’s Manual

Page 62 / 66

Reference: FDE 31 08 972 Issue Z

Page 64

READ FONT INFORMATION Synopsis Syntax Operand Limit Returns

Description

Read Font information and checksum ASCII: FS F t Hex: 1C 46 t t: Font storage Id Hex: 0x30 ≤ t ≤ 0x34 ASCII: OK: ACK followed by font name = 8 bytes ASCII string font width = 1 byte font height = 1 byte number of characters = 2 bytes (little endian) 16 bit checksum = 2 bytes (little endian) Fault: NAK If selected font exists, this command returns ACK followed by font information. Else it returns NAK.

CHECK EASYFONT COMPATIBILITY Synopsis Syntax Returns

Description

Check EasyFont compatibility ASCII: FS H Hex: 1C 48 ASCII: OK: ACK + list of available font Ids + 00 Fault: NAK Hex: OK: 06 + list of available font Ids + 00 Fault: 15 This command asks the printer whether it supports or not Easyfont. If it does, it also returns the list of available font Ids (single byte, double byte) that can be used to download a font.

TPSK 12 & 24 V User’s Manual

Page 63 / 66

Reference: FDE 31 08 972 Issue Z

Page 65

6 RECOMMENDATIONS 6.1 Storage: If the printer has been stored for a long time with paper set below the print head, it may be necessary to re-load the paper before operating.

6.2 Duty cycle: If the temperature is greater than 60°C, the printer must not be used to print more than one ticket (with maximum length 5 inches) per minute. If the temperature is lower than 60°C, the printer can be used up to 3 tickets (with maximum length 5 inches) per minute. Higher duty cycle can destroy the paper feed motor. Printing is stopped thanks to a software security feature, if the temperature of the print head becomes too high. Printing will re-start after cooling.

6.3 Grounding: The printer must be grounded. This can be done either by setting it on a grounded metal support or by connecting its external chassis.

6.4 Print head Cleaning: This printer is designed with the print head facing down, this avoid dust accumulation. However, in heavy duty condition or if the paper used has a poor quality, it is recommended to clean the print head. The print head is visible and accessible when the door is opened. To clean the heating dots of the head, use a cotton stick containing a solvent alcohol (ethanol, methanol, or IPA), but do not touch the print head with your fingers! AXIOHM can provide cleaning kits, ref.: CK60000A

6.5 Ticket access / Housing features: To maintain printer reliability, the pressure on the Clamshell door must be limited. In case of sealing needs, make sure the pressure applied to the door is lower than 6 lbs. This pressure must be applied around the ticket exit chute. Please contact Axiohm Technical Support team for specific integration.

TPSK 12 & 24 V User’s Manual

Page 64 / 66

Reference: FDE 31 08 972 Issue Z

Page 66

6.6 Paper recommendations: •

KP440 KANZAN paper

Property

Method

Unit

Value

Grams Thickness Surface smoothness Brightness Whiteness Tensile strength

ISO 536 ISO 534 ISO 5627 (Beck) R457Macbeth RD 914 ISO 1924/1 g/m2 µm sec % OD KN/m

Tear Strength

ISO 1974 mN

Color Image Saturation Density Initiation T° Saturation T° Moisture content

Dynamic test Heated platen Heated platen ISO 287

Macbeth RD914 °C °C %

TPSK 12 & 24 V User’s Manual

Page 65 / 66

58 +/- 5 64 +/- 4 300 min 75 min 0.09 min > 3.3 MD > 2 CD > 250 MD > 250 CD Black 1 min 75 ± 5 100 ± 5 6.5 ± 1.0

Reference: FDE 31 08 972 Issue Z

Page 67

7 TROUBLESHOOTING Situation

Problem

Solution

Paper loading: When the paper is correctly loaded and the printer is powered, closing the door will generate a self-test ticket.

The self-test ticket is not printed.

Check if the printer is powered.

Printing tickets:

Printer prints blank tickets.

Check if the paper end is tight enough: - Open the door. - Keep the paper end tight from the chute outlet. - Close the door; printing of the self-test should begin. Make sure the paper roll is not set upside down; see the instruction label inside the printer.

Tickets do not come out: Even though no error message is sent. Even though tickets are required, and the printer makes noise as if it was printing.

Open the printer door. Check if there is a small black plastic part (paper guide) between the roller and the white plastic flap. This guide is clipped to the roller axle and attached to the white flap; if it is missing, there is a gap between the roller and the flap in which the paper can be fed.*

Printer prints erratic characters.

A wrong baud rate could be the cause:

Printer does not start printing, even though paper path is clear and there is no visible jam.

The baud rate is indicated on the self-test ticket, which can be printed by closing the door. If your application can detect status return, check the sensor status. If your application does not detect the status return, or you cannot easily check them: Make sure that all sensors are plugged in correctly - Four connectors on the right side of the PCB, from top to bottom: 4 contacts, 3 contacts, 2 contacts with red wires, 2 contacts with black wires. Check the door switch for contact (small mushroom switch on the left of the printer mechanism). When applying pressure to the switch, it should make a noise; if it does not, there is no contact and the switch may need to be replaced.

* For replacement of this part, call maintenance.

TPSK 12 & 24 V User’s Manual

Page 66 / 66

Reference: FDE 31 08 972 Issue Z