The text of a manual · part 12 of 13
Using the ArgoxScan 8110/8120/8150/8250/8310/8312: All Scanner Manual PN 49-81101-008.pdf, pages 105 to 114
Pages 105 to 114 of 123, from Using the ArgoxScan 8110/8120/8150/8250/8310/8312
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Argox AS-8150
Page 105
Micro-PDF (for 8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
*XAA*
Disable
00
Enable
01
0-15
00-15
Read
*XAF*
00
Truncate leading 0-15
*XAG*
00-15 00
Truncate ending
*XAH*
00-ffH ASCII
00-ffH code
<
Code ID setting
100
>
Page 106
00-44
*XAI*
00-44
00
Insert group number selection None
00
*XAJ*
GLI protocol
01
Escape sequence
ECI protocol
02 transmit
Exit
101
Page 107
String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies. Up to 22 ASCII characters can be defined as Prefix or Suffix. Format of barcode data transmission: Prefix Name Preamble ID
Code Barcode Length
Data
ID Postamble
Insert groups
.
102
Suffix
Page 108
Program Option Bar Code
Option
Alphanumeric Entry
None
00
1-22 characters
00-ffH ASCII
Prefix characters code setting
None
0D
1-22 characters
00-ffH ASCII
Suffix characters code setting
Exit
103
Page 109
String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data automatically for all symbologies. However, the transmission will not activate unless Preamble / Postamble transmission is enabled. Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies. Steps: 1) Scan Programming and Prefix characters setting barcode. 2) Use the ASCII code table to find the value of $ 24. 3) Scan 2 and 4 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page. 5) Scan Exit barcode.
!
104
Page 110
Program Option Bar Code
Option
Alphanumeric Entry
None
00
1-22 characters
00-ffH ASCII
Preamble characters code setting
Disable
00
Enable
01
None
00
1-22 characters
00-ffH ASCII
Preamble transmission
Postamble code characters setting Disable
00
Enable
01
Postamble transmission
Exit
105
Page 111
String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The scanner supports inserting two groups with each group 22 characters into transmitted data of selected symbologies. The two groups can be inserted into scanned data of the selected symbologies or positioned at leading / ending of data. There are total four groups for utilization. Insert data group position: To define the position of a group to insert into bar code data. Please notice that the inserting position of a group must not exceed the code length; or the insertion will be positioned at the ending of data. Notice: Default value “00” indicates the group to be positioned at the leading of data. “64” represents for positioning the group at the ending of data. Insert data group setting procedure: i. Define the characters of groups for insertion. ii. Setup the inserting position of each group in scanned data. iii. Select one or two groups to insert into specific bar codes. Please refer to the setting pages of each bar code. Example: Barcode “1 2 3 4 5 6”. Output- Barcode “1 2 A B 3 4 C D 5 6”. Steps: 1) Scan Programming and Insert G1 characters setting barcode. 2) Use the ASCII code table to find the value of A 41,B 42. 3) Scan 4, 1 and 4, 2 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page.
!
106
!
Page 112
5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 6) Insert data group 1-4 position. Please refer to ChapterTransmission, page 65 and in specific barcode that you want to use. 7) Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00” to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective.
Program Option Bar Code
Option
Alphanumeric Entry
None
00
1-22 characters
00-ffH ASCII
Insert G1 characters code setting
None
00
1-22 characters
00-ffH ASCII
Insert G2 characters code setting
Exit
107
Page 113
String setting / Transmission (Insert Group Characters)
Program
None
00
1-22 characters
00-ffH ASCII
Insert G3 characters code setting
None
00
1-22 characters
00-ffH ASCII
Insert G4 characters code setting 00-63
00-63
(00: no insertion)
00
00-63
00-63
(00: no insertion)
00
00-63
00-63
(00: no insertion)
00
Insert data group 1 position
Insert data group 2 position
Insert data group 3 position
108
Page 114
00-63
00-63
(00: no insertion)
00
Insert data group 4 position
Exit
109