Page 105

Micro-PDF (for 8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

*XAA*

Disable

00

Enable

01

0-15

00-15

Read

*XAF*

00

Truncate leading 0-15

*XAG*

00-15 00

Truncate ending

*XAH*

00-ffH ASCII

00-ffH code

<

Code ID setting

100

>

Page 106

00-44

*XAI*

00-44

00

Insert group number selection None

00

*XAJ*

GLI protocol

01

Escape sequence

ECI protocol

02 transmit

Exit

101

Page 107

String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies. Up to 22 ASCII characters can be defined as Prefix or Suffix. Format of barcode data transmission: Prefix Name Preamble ID

Code Barcode Length

Data

ID Postamble

Insert groups

.

102

Suffix

Page 108

Program Option Bar Code

Option

Alphanumeric Entry

None

00

1-22 characters

00-ffH ASCII

Prefix characters code setting

None

0D

1-22 characters

00-ffH ASCII

Suffix characters code setting

Exit

103

Page 109

String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data automatically for all symbologies. However, the transmission will not activate unless Preamble / Postamble transmission is enabled. Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies. Steps: 1) Scan Programming and Prefix characters setting barcode. 2) Use the ASCII code table to find the value of $ 24. 3) Scan 2 and 4 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page. 5) Scan Exit barcode.

!

104

Page 110

Program Option Bar Code

Option

Alphanumeric Entry

None

00

1-22 characters

00-ffH ASCII

Preamble characters code setting

Disable

00

Enable

01

None

00

1-22 characters

00-ffH ASCII

Preamble transmission

Postamble code characters setting Disable

00

Enable

01

Postamble transmission

Exit

105

Page 111

String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The scanner supports inserting two groups with each group 22 characters into transmitted data of selected symbologies. The two groups can be inserted into scanned data of the selected symbologies or positioned at leading / ending of data. There are total four groups for utilization. Insert data group position: To define the position of a group to insert into bar code data. Please notice that the inserting position of a group must not exceed the code length; or the insertion will be positioned at the ending of data. Notice: Default value “00” indicates the group to be positioned at the leading of data. “64” represents for positioning the group at the ending of data. Insert data group setting procedure: i. Define the characters of groups for insertion. ii. Setup the inserting position of each group in scanned data. iii. Select one or two groups to insert into specific bar codes. Please refer to the setting pages of each bar code. Example: Barcode “1 2 3 4 5 6”. Output- Barcode “1 2 A B 3 4 C D 5 6”. Steps: 1) Scan Programming and Insert G1 characters setting barcode. 2) Use the ASCII code table to find the value of A 41,B 42. 3) Scan 4, 1 and 4, 2 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page.

!

106

!

Page 112

5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 6) Insert data group 1-4 position. Please refer to ChapterTransmission, page 65 and in specific barcode that you want to use. 7) Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00” to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective.

Program Option Bar Code

Option

Alphanumeric Entry

None

00

1-22 characters

00-ffH ASCII

Insert G1 characters code setting

None

00

1-22 characters

00-ffH ASCII

Insert G2 characters code setting

Exit

107

Page 113

String setting / Transmission (Insert Group Characters)

Program

None

00

1-22 characters

00-ffH ASCII

Insert G3 characters code setting

None

00

1-22 characters

00-ffH ASCII

Insert G4 characters code setting 00-63

00-63

(00: no insertion)

00

00-63

00-63

(00: no insertion)

00

00-63

00-63

(00: no insertion)

00

Insert data group 1 position

Insert data group 2 position

Insert data group 3 position

108

Page 114

00-63

00-63

(00: no insertion)

00

Insert data group 4 position

Exit

109