Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 4

Using the ArgoxScan 8000/8120/8150/8250/8310/8312, pages 1 to 9

Pages 1 to 9 of 33: Pre - All Scanner QIG PN 49-81102-001.pdf; All Scanner QIG PN 49-81102-001.pdf

The original document is the PDF (396 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Argox AS-8150

Page 1

NOTICE:

This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including interface that may cause undesirable operation. This equipment has been tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide a reasonable protection against harmful interface when the equipment is operated under a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interface to radio communications. Operation of this equipment in a residential area is likely to cause harmful interface in which case the user will be required to correct the interface at his own expenses. Note: All brands and trademarks shall belong to their respective owner. Note: Specification is subject to changes without notice.

Page 2

Using the ArgoxScan 8000/8120/8150/8250/8310/8312 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. Successful scanning shall be obtained by tilting the scanner with respect to the barcode to avoid direct reflections that impair the reading performance, especially for 2D barcode. Recommended Steps When the required settings have been configured, all settings are stored in non- volatile memory of scanner after reading EXIT Label. Recommended steps are as follows. 1)

Set right host interface for your scanner. (The scanner is in factory default shown as bold label)

2)

Set interface to optimize protocol of scanner with your host in interface section.

3)

Set system control of scanner, such as specific adjustments double confirm, power saving, indicator and scanning mode which you prefer usage in system control section.

4)

Set code options of scanner for your usage in code option section. You must make sure to enable the symbology first, then Min./Max. code length, code ID checksum and truncate digits are also converted.

5)

Set string format of the scanner, such as preamble, postamble Prefix, suffix, code ID and code name transmission for your application in string format section. Note: If still not work properly. Please contact your dealer for further information.

Page 3

Introduction Installation- Keyboard Wedge 1) 2) 3) 4)

First of all, you must switch off power for the terminal/computer. Disconnect the keyboard cable from the back of the terminal/computer. Connect the appropriate interface cable to the scanner and to the terminal/computer. Turn the terminal/computer power on.

RS-232 1) 2) 3)

4) 5)

Disconnect power to the terminal/computer. Connect the appropriate interface cable and external power supply (DC adapter) to the scanner. Plug the serial connector into the serial port on the back of your computer/terminal. Tighten the two screws to secure the connector to the port. Plug the power pack into power source. Once the scanner has been fully connected, turn the terminal/computer power back on.

USB (Simulate with keyboard wedge) 1) 2)

Connect the USB cable between scanner and PC. Windows will automatically detect the USB device.

Note: If any of the above operation is incorrect, turn off the power immediately and check any improper connections. Go through all above steps again. Note: If you need more programming parameters to setup your ArgoScan scanner, please go to www.argox.com and download the completed user’s manual.

0

Page 4

Programming the ArgoScan 8110/8120/8150/8250/8310/8312 To program the 8110/8120/8150/8250/8310/8312, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.

To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3. To the right of the option barcode, the necessary alphanumeric inputs are listed. Scan these alphanumeric entries from the back fold out page. To confirm above steps, you must scan the Finish barcode on the back fold out page. 4. Once you have finished programming. Scan the Exit barcode, listed on the lower right hand corner of each parameter setting part.

1

Page 5

Interface Selection Keyboard Wedge

RS-233

Wand Emulation (8110/8150/8250)

USB

Keyboard /RS232/USB

*

Auto detection

Keyboard Layout USA *

Belgium

Danish

2

Page 6

Keyboard Layout - Continued France

Germany

Italian

Portuguese

Spanish

Swedish

Switzerland

UK

Latin American

Japanese

3

Page 7

RS-232 Flow Control None *

RTS/CTS

Xon/Xoff

ACK/NAK

RS-232 Baud Rate Setting 300 BPS

600 BPS

1200 BPS

2400 BPS

4800 BPS

9600 BPS *

4

Page 8

RS-232 Baud Rate Setting (Continued) 19200 BPS

38400 BPS

RS-232 Parity Setting None *

Odd

Even

RS-232 Data Bit Setting 8 bits *

7 bits

5

Page 9

Pin Assignments AS Series 8-pin RJ-45 Connector Pin

RS-232

Keyboard

1

VCC (+5V)

VCC (+5V)

2

TXD

NC

3

NC

CLK / PC

4

NA

DATA / PC

5

CTS

DATA / KB

6

RXD

NC

7

RTS

CLK / KB

8

GND

GND 1 2 3 4 5 6 7 8 9 10

1 2 3 5 46 7 8 8-pin

10-pin

AS Series 10-pin RJ-45 Connector Pin

RS-232

Keyboard

1

I/F

I/F

2

VCC (+5V)

VCC (+5V)

3

TXD

NC

4

NC

CLK / PC

5

GND

DATA / PC

6

CTS

DATA / KB

7

RXD

NC

8

RTS

CLK / KB

9

GND

GND

10

NC

GND

6