Two-page quick start guide for the AMX Axcent3 and Axcent3 Pro controllers. It sums up size, power, memory and every connector with its pinout, device and channel numbers, and lists the main Send_Commands for the serial, IR and input/output ports.
- Device
- Axcess central controller with serial, relay, IR/serial/data and input/output ports; the Axcent3 Pro adds four Axcess Control Card slots p. 1
- Power
- Axcent3: 600 mA @ 12 VDC; Axcent3 Pro: 650 mA @ 12 VDC without Axcess control cards p. 1
- Size and weight
- Axcent3: 3.47" x 17.0" x 3.0" (HWD), 2.5 lbs (1.1 kg); Axcent3 Pro: 3.47" x 17.0" x 13.65", 5.6 lbs (2.6 kg) without control cards p. 1
- Serial ports
- Six 9-pin male D-sub RS-232/422/485 ports, XON/XOFF and CTS/RTS; RS-232 range 50' (15.24 m) max p. 1
- Port settings
- 300 to 38400 baud or AUTO; parity N, O, E, M or S; 7 or 8 data bits; 1 or 2 stop bits; RS-485 or RS-422 mode p. 2
- Relays
- 8 isolated, normally open relays; 750 mA, 28 VAC/24 VDC p. 1
- IR/serial/data ports
- Six ports on a 12-pin male connector for IR, IR/serial or one-way data; carriers up to 1.14 MHz; 0 - 5 VDC levels only p. 2
- Input/output ports
- Six I/O ports on an 8-pin connector; contact closure or TTL inputs; outputs rated 200 mA @ 12 VDC; +12 VDC tap 200 mA p. 2
- Memory
- Volatile 128Kbx16, non-volatile 256Kbx16 p. 1
- Program port
- DB-9 male on front and rear panels; downloads Axcess programs and sets communication options with OpenAxcess p. 1
- Power connector
- AXlink/PWR: 4-pin AXlink data and power plus a 2-pin connector for an external 12 VDC supply p. 1
- Device numbers
- Serial ports 1 - 6, relays 7, IR/serial/data 8 - 13, I/O 14, card slots 15 - 18 p. 1, 2
- AXlink LED codes
- 1 blink/second normal; 2 blinks/second device number mismatch or missing device; 3 blinks/second AXlink bus error; full on no program p. 1
- IR emitter
- CC-IRC Infrared Emitter connects to the IR/SERIAL/DATA connector p. 2
What this manual walks you through
- Preparing and connecting captive wires p. 1
- Wiring the RS-232, RS-422 and RS-485 DB-9 pins p. 1
- Wiring AXlink data and power, with or without a separate 12 VDC supply p. 1
- Connecting relay devices p. 1
- Connecting IR, serial and data devices and their Send_Commands p. 2
- Connecting input/output devices and setting input states p. 2
- Setting serial port parameters with SET BAUD p. 2
Good to know
- With a separate 12 VDC supply, connect only the GND wire to the AXlink/PWR connector, not the PWR wire. p. 1
- Do not over-tighten the captive-wire screws; it can bend the seating pin. p. 1
- Data devices on the IR/SERIAL/DATA connector are transmit only, at 0 - 5 VDC levels only. p. 2
- Full programming details are in the accompanying instruction manual. p. 2
Questions this manual answers
How much current does the Axcent3 draw?
The Axcent3 draws 600 mA at 12 VDC; the Axcent3 Pro draws 650 mA at 12 VDC without control cards. p. 1
How do I put an Axcent3 serial port into RS-485 mode?
Send the SET BAUD command with 485 ENABLE, for example SET BAUD 9600,N,8,1,485 ENABLE. p. 2
What are the Axcent3 device numbers?
Serial ports are devices 1 - 6, relays 7, IR/serial/data ports 8 - 13, I/O 14, and the Pro's card slots 15 - 18. p. 1, 2
How do I list the Axcent3 PROGRAM port commands?
Type a question mark in the terminal connected to the PROGRAM port. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Quick Start Guide Axcent3 and Axcent3 Pro Dimensions (HWD) and Weight:
Axcent3: 3.47" x 17.0" x 3.0" (88.1 mm x 432 mm x 76.2 mm) and is 2.5 lbs (1.1 kg) 3
Axcent Pro: 3.47" x 17.0" x 13.65" (88.1 mm x 432 mm x 76.2 mm) and is 5.6 lbs (2.6 kg) without Axcess control cards
The following table lists the connector pins, signal types, signal functions, wiring, and baud configurations. DB-9 Pinouts and Wiring and Baud Configurations Pin
Signal1RX-Receive data2RXDReceive dataX3TXDTransmit dataX4TX+Transmit data5GNDSignal ground6RX+Receive data7RTSRequest to sendX8CTSClear to sendX9TX-Transmit dataPower Requirement: •
Axcent3: 600 mA @ 12 VDC
Axcent3 Pro: 650 mA @ 12 VDC (without Axcess control cards)
Memory:
Volatile memory: 128Kbx16 (user-modifiable) Non-volatile memory: 256Kbx16 (user-modifiable)
PROGRAM PORT (Front and Rear Panels): PROGRAM port: DB-9 (male) connector for system programming. Connect a programming cable to the PROGRAM connector on the controller. Use the PROGRAM connector to download Axcess programs, and set up control communication options using the OpenAxcess software program. See the table below. Program Connector and Pinouts Pins Signal
pin 12PROGRAMpin 9RXD3TXD4+12 VDC5GND7+12 VDC
AXlink Indicator (Front and Rear Panel): Green LED that shows power and AXlink communication activity. Blink patterns include:
- Off - No power or the controller is not functioning properly.
- 1 blink/second - Normal operation. Device numbers match the programmed device numbers in the Axcess program.
- 2 blinks/second - Device numbers do not match the Axcess program, a device is not present, or a device is not set to the right number.
- 3 blinks/second - AXlink bus error. Check all AXlink bus connections.
- Full on - Axcess program is not present and there is no AXlink activity.
Slots 1 - 4 (Axcent3 Pro Only - Front and Rear Panel): Four 16-pin connectors for Axcess Control Cards (See FIG. 1).
- Device numbers: 15 - 18
- Channels: Card dependent
FunctionRS-232XRS-422RS-485XX (strap to pin 9)XX (strap to pin 6)X XX (strap to pin 4)XX (strap to pin 1)
The X’s show where to terminate the wires on the DB-9 connector.
AXlink/PWR Connector (Rear Panel): 4-pin connector for AXlink data and power, and 2-pin connector for external 12 VDC power supply. Connect the AXlink connector to an external AXlink device, as shown in FIG. 2. PWR+
PWR+ AXPAXP/TX AXM/RX GND-External AXlink deviceAXM GND-
AXlink/PWR connector FIG. 2 AXlink/PWR data and power wiring diagram
Connect the 4-pin AXlink connector to an external AXlink device; connect the 2-pin PWR connector to the separate 12 VDC power supply as shown in FIG. 3. Make sure to connect only the GND wire on the AXlink/PWR connector when using a separate 12 VDC power supply. Do not connect the PWR wire to the AXlink connector’s PWR (+) opening. PWR+ GNDPWR+
Local 12 VDC power supply for ext. AXlink device PWR+ AXP
AXP/TX AXM/RX GND-AXM GND-External AXlink device
Axcent3 FIG. 3 AXlink/PWR and optional 12 VDC power supply wiring diagram
Relay Connectors: SLOT 1
FIG. 1 Axcent3 Pro Axcess Control Card connector
Preparing and Connecting Captive Wires: 1. 2.
Strip 0.25 inch of wire insulation off all wires. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types. Turn flat-head screws clockwise. Do not over-torque the screw; doing so can bend the seating pin and damage the connector.
3.
Two 8-pin connectors, 750 mA, 28 VAC/24 VDC (normally open).
- Device number: 7
- Channels: 1 - 8 Connect up to 8 independent external relay devices to the 16-pin RELAYS connector, as shown in FIG. 4. Use A for common and B for output. Each relay is isolated and normally open. A metal connector strip is also provided to common multiple relays. 8 B
7 AB56 ABAB34 ABAB
RS-232/RS-422/RS-485 Connectors (Rear Panel):
The RS-232 range is 50’ (15.24 m) max. RS-232/RS-422/RS-485 ports: Six 9-pin (male) D-sub, RS-232/422/485 XON/XOFF, CTS/RTS, 300, 200 baud.
- Device numbers: 1 - 6
- Channels: 1 - 255; The RS-232/422/485 ports provide CTS input feedback on channel 255 when you use the CTSPSH Send_Command.
RELAYS
FIG. 4 RELAY 16-pin connector
2 AB1 ABA
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
IR/SERIAL/DATA Connectors: 12-pin male connector that supports: IR, IR/Serial or one-way data communication.
- Device numbers: 8 - 13
- Channels: 1 - 254; 6 IR/Serial/Data control ports that support highfrequency carriers up to 1.14 MHz, and 1-way data, 300-38, 400 baud (0 - 5 VDC levels only). Connect up to 6 IR, IR/Serial, and/or DATA (transmit only, 0 - 5 VDC levels only) devices to the 12-pin IR/SERIAL/DATA connector shown in FIG. 5. You can connect a CC-IRC Infrared Emitter, external serial device, or data 0 - 5 VDC device using a 2-pin captive-wire. 5
6432
Send_Commands for the IR/Serial/Data Ports ‘CAROFF’
Disables carrier from responding until a CARON command is received. This command overrides active software settings. Example: SEND_COMMAND IR_1,’CAROFF’ Stops transmitting the IR carrier signal.
‘CARON’
Enables the carrier to respond according to active software settings. Example: SEND_COMMAND IR_1,’CARON’ Starts transmitting the IR carrier signal.
‘POF’
Send IR function 28 (if available) or 9 to turn device power off. After 3 attempts, if the linked I/O channel still detects a power-on status, the controller starts processing stored buffer commands. Then, if another IR function 28 or 9 fails to turn the external device’s power off, the controller sends a PUSH and RELEASE of channel 248 and generates a power failure error. If the device is turned on manually, this command turns the external device’s power off unless a PON (power on) or POD (disable POF) command is received. Refer to the SET IO LINK command.
‘PON’
Sends IR function 27 (if available) or 9 to turn device power on. After 3 attempts, if the linked I/O channel still detects a power-off status, the controller starts processing stored buffer commands. Then, if another IR function 27 or 9 fails to turn the external device’s power on, the controller sends a PUSH and RELEASE of channel 248 and generates a power failure error. If the device is turned off manually, this command turns external device power on unless a POF (power off) or POD (disable PON) command is received.
‘SET MODE’
Sets the IR/Serial/Data port for IR-, Serial-, or Data-controlled devices that connect to the port. Syntax: ‘SET MODE (MODE)’ Variables: Mode = IR, SERIAL, or DATA Example: SEND_COMMAND IR_1,’SET MODE IR’ Sets the IR_1 port to IR mode so an IR-controlled device can be connected to the port.
‘SET IO LINK’
Links an IR/Serial/Data port to an input/output (I/O) channel for use with PON and POF commands. The I/O channel can sense 0 - 5 VDC using a PCS or PCS2 Power Current Sensor. Set the I/O channel to 0 to disable the link function. Example: SEND_COMMAND IR_1,’SET IO LINK 1’ Sets the IR_1 port link to I/O port 1. The IR port uses the specified I/O input as power status for processing PON and POF commands.
1
IR / SERIAL / DATA
FIG. 5 IR/SERIAL/DATA 12-pin connector
- Input/Output Connectors
- GND
I/O1I/O2I/O3I/O4I/O512VI/O6
8-pin connector, I/O 1- 6, Common, +12 VDC power tap 200 mA, contact closure or TTL logic inputs.
- Device number: 14
- Channel numbers: 1 - 6 Connect up to 6 input/output (I/O) devices to the INPUT/OUTPUT 8-pin connector, as shown in FIG. 6. A contact closure between GND and an I/ O port is detected as a PUSH. When used for a voltage input, the I/O port detects a low (0 - 1.5 VDC) as a PUSH, and a high signal (3.5 - 5 VDC) as a RELEASE. When used for an output, each I/O port acts as a switch to GND and is rated at 200 mA @ 12 VDC.
INPUT / OUTPUT
FIG. 6 INPUT/OUTPUT 8-pin (male) connector
Setup Programming Commands: PROGRAM Port commands can be accessed in the terminal by typing “?”. For detailed programming information, refer to the accompanying manual. Send_Commands for RS-232/422/485 Mode ‘HSOFF’
Disables hardware handshaking (default).
‘HSON’
Enables hardware handshaking.
‘XOFF’
Disables software handshaking (default).
‘XON’
Enables software handshaking.
‘Set Baud’
Syntax: ‘SET BAUD (Baud),(Parity),(Data), (Stop) [485(DISABLE/ENABLE)]’ Variables: Baud = 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 or AUTO Parity = N (none), O (odd), E (even), M (mark), S (space) Data = 7 or 8 bits Stop = 1 or 2 bits Disable = disables RS-485 mode, and enables RS-422 Enable = enables RS-485 mode, and disables RS-422 Example: SEND_COMMAND RS232_1,’SET BAUD 9600,N,8,1,485 ENABLE’ Sets the RS232_1 port’s communication parameters to 9,600 baud, no parity, 8 data bits, 1 stop bit, and enables RS-485 mode.
‘Get Baud’
- Syntax
- ‘GET BAUD’
Send_Commands for Input/Output Ports ‘Set Input’
Syntax: ‘SET INPUT (Port) (State)’ Sets the input channel’s active state. An active state can be high (logic high) or low (logic low or contact closure). Channel changes, pushes, and releases generate reports based on their active state. Variables: Port = 1 - 6 State = High or Low Example: SEND_COMMAND IO,’SET INPUT 1 HIGH’ Sets I/O port to detect a high state change.
‘Get Input’
Syntax: ‘GET INPUT (Port)’ Gets the input channel’s active state. An active state can be high (logic high) or low (logic low or contact closure). Channel changes, pushes, and releases generate reports based on their active state. Variables: Port = 1 - 6 Example: SEND_COMMAND IO,’GET INPUT 1’ Gets I/O port’s active state.
Gets the RS-232/422/485 port’s current communication parameters. The port sends the data through the master’s PROGRAM port. Example: SEND_COMMAND RS232_1,’GET BAUD’ System response example: Device 1, 38400, N, 8, 1, 485 DISABLED
AMX Corporation reserves the right to alter specifications without notice at any time. For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s). 030-004-2496 8/05 ©2005 AMX Corporation. All rights reserved. The AMX logo is a trademark of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com