Page 28

Axcess Programming

24

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Page 29

Replacing the Lithium Batteries

Replacing the Lithium Batteries There are two lithium batteries on the controller’s circuit card with a life of approximately five years. They protect stored commands against power loss. The batteries are not used when DC power is supplied to the controller. You should write down the replacement date on a sticker or label by adding five years to the date of installation, and then attach it to the rear panel for future reference. Static electricity can damage electronic circuitry. Before removing the touch panel circuit card from the enclosure, discharge any accumulated static electricity from your body and flat-blade tool by touching a grounded metal object.

Contact your dealer before you replace the lithium batteries and verify they have a current copy of the software program stored in the controller. This will avoid any inadvertent loss of data or a service outage. To remove the controller’s top panel, you will need a Phillips screwdriver. You need non-conducting pliers to remove the lithium batteries from the controller. 1. Discharge the static electricity from your body by touching a grounded object. 2. Disconnect all power and data cables from the controller. 3. Hold the controller in place, and remove the mounting hardware from the equipment rack. Then, carefully remove the controller from the rack and place it on a flat surface. 4. Remove the six Phillips-head screws from the top panel on the controller. Then, remove the screws from the left and right side of the Axcent3 and Axcent3 Pro controller as shown in FIG. 11. Top panel screws

Side panel screws

Axcent3 Controller

Axcent3 Pro Controller

FIG. 11 Top and side panel screw locations

5. Remove the top panel and locate the batteries on the circuit card.

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

25

Page 30

Replacing the Lithium Batteries

6. Carefully push the lithium battery, located in position B2, out of its socket, and remove with non-conduction pliers. With the rear of the unit facing you, insert the new battery with the positive (+) polarity side facing left. Do not use any type of conductive tools to remove the battery. Doing so will damage the battery.

7. Plug the AXlink and power connectors back into the AXLINK/PWR connectors on the controller. Then, remove the connectors again. Be sure to write down the next replacement date on a sticker or label by adding five years to the replacement date, and then attach it to the back panel of the controller. 8. Repeat step 6 and 7 for the battery in position B1. 9. Place the top panel on the controller and align the screw holes. Insert the six Phillips-head screws and tighten. Then, insert screws in the left and right side of the controller and tighten. 10. Place the controller in the equipment rack, and align the mounting holes. Then, install the mounting hardware and tighten. 11. Connect all power and data cables back into the controller.

26

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Page 31

Updating Firmware

Updating Firmware This section describes how to update the firmware in the controllers using the SOFTROM software program. Your PC must be connected to the PROGRAM DB-9 connector on the controller using a serial RS-232C-compatible cable. Refer to the Wiring the Axcent3 section on page 5 for detailed wiring information. To update: 1. Place the AMX SOFTROM diskette into drive A or B of your PC. 2. At the MS-DOS prompt C:>, type A:\ and press the ENTER key. 3. When the A:\> prompt appears on the screen, type SOFTROM and press the ENTER key.

Configuration To configure the communication setting for the SOFTROM program: 1. Press F1 and the Configure screen appears. Make sure the BAUD RATE selections match the setting on the Axcess System Master controller. 2. Using the up/down arrow keys, select the communications port you are using to interface with the controller and press ENTER. 3. Using the right arrow key, move to the BAUD RATE column. Then use the up/down arrow keys to select the interface communications speed. Press ENTER. 4. Press F10 to save the communication settings and to exit the CONFIGURE screen. F2 can be pressed to select all ONLINE PANEL devices and F3 can be pressed to clear all devices.

Downloading Firmware To download the firmware: 1. Press F5 to acquire the list of online programmable devices. 2. Using the up/down arrow keys, select your firmware versions listed in the Firm-ware column of the screen and press ENTER. 3. Using the Tab key, switch to the ONLINE MASTERS list. 4. Using the up/down arrow keys, select the devices to be programmed. Press ENTER for each device as it is selected. 5. Press F4 to program the selected devices; a loading message appears on the screen. 6. Press F5 to refresh the screen. Verify that the selected controllers have the correct firmware version. If any devices still indicated the old version, repeat steps 3-5 until all controllers appear with the correct firmware version. 7. Press F10 to exit the SOFTROM program.

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

27

Page 32

Updating Firmware

Device number

Version number

Type number

Firmware

Loading status and device number FIG. 12 Loading message

Firmware can be downloaded to multiple device numbers automatically. If multiple devices are selected, the bottom half of the loading bar will indicate the percentage complete for the selected devices.

28

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Page 33

Updating Firmware

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

29

Page 34

ARGENTINA • AUSTRALIA • BELGIUM • BRAZIL • CANADA • CHINA • ENGLAND • FRANCE • GERMANY • GREECE • HONG KONG • INDIA • INDONESIA • ITALY • JAPAN LEBANON • MALAYSIA • MEXICO • NETHERLANDS • NEW ZEALAND • PHILIPPINES • PORTUGAL • RUSSIA • SINGAPORE • SPAIN • SWITZERLAND • THAILAND • TURKEY • USA ATLANTA • BOSTON • CHICAGO • CLEVELAND • DALLAS • DENVER • INDIANAPOLIS • LOS ANGELES • MINNEAPOLIS • PHILADELPHIA • PHOENIX • PORTLAND • SPOKANE • TAMPA

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0913 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • www.amx.com

Last Revision: 09/12/05

030-004-1590 9/05 ©2005 AMX Corporation. All rights reserved. AMX, the AMX logo, the building icon, the home icon, and the light bulb icon are all trademarks of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. *In Canada doing business as Panja Inc.

AMX reserves the right to alter specifications without notice at any time.