Manual · AML
AML M6000 Set Up Guide
Manual2 pagesPDF 44 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
A two-page setup menu (version 1.7) of programming bar codes for the Model 6000, 6200 and 6300 readers, with a full ASCII chart on the second page. It lets the reader turn symbologies and check digits on or off, add a preamble or postamble, edit bar code data, set the termination character, trigger mode and beeps, and reset defaults.
- Document
- Bar code setup menu for the Model 6000/6200/6300, version 1.7 p. 1
- Symbologies
- Code 39, EAN, UPC, Interleaved 2 of 5, Code 128, Codabar, Code 93, MSI/Plessey, Code 11 and UPC/EAN supplements p. 1
- Trigger modes
- Trigger mode (default) or pulse mode; continuous and blink modes are not available on the M6000 p. 1
- Termination character
- None, horizontal tab, carriage return (default), carriage return & line feed, user defined character, or numeric key pad enter p. 1
- Preamble and postamble
- Characters from the full ASCII chart, a send delay of 0.0 - 9.9 sec, and the bar code types they apply to p. 1, 2
- Bar code edit
- Strip a number of leading or trailing characters by bar code type, and strip leading and trailing spaces p. 1
- Bar code options
- Send bar code type ID, duplicate reads, bar code function and special keys, termination override, keyboard auto caps/num lock, alternate numeric keys p. 1
- Shutdown time
- Portable shutdown time 00-99 minutes, default 10 minutes; 00 means no shutdown p. 1
- Diagnostics
- Performs a self-test and sends the status to the host p. 1
- ISBN
- ISBN conversion under EAN and ISBN Plessey under MSI/Plessey p. 1
What this manual walks you through
- Programming the reader with setup bar codes p. 1
- Turning symbologies and check digits on or off p. 1
- Adding a preamble or postamble from the ASCII chart p. 1, 2
- Setting the scan and acknowledge beeps p. 1
- Resetting options to their defaults p. 1
Good to know
- Continuous and blink modes are not available on the M6000; on the M6200 they disable RF communications. p. 1
- All delay and fixed length entries need two digits scanned. p. 1
- Scan ON when finished entering preamble or postamble characters. p. 1
Questions this manual answers
How do I program the Model 6000 scanner?
Scan START, then the category bar code, then the option number, then ON or OFF or characters from the ASCII chart, and finish with EXIT (SAVE CHANGES). p. 1
How do I reset the M6000 to factory defaults?
Scan RESET ALL DEFAULTS; option 9 resets only the current category. p. 1
Does the M6000 support continuous scanning mode?
No. The menu states continuous and blink modes are not available on the M6000. p. 1
How do I make the M6000 send a carriage return after each scan?
Carriage return is the default termination character; it is chosen under TERMINATION CHARACTER. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
MODEL 6000/6200/6300 SETUP MENU START
CODE 39
« 0) CODE 39 DECODER 1) FULL ASCII 2) MOD 43 CHECK DIGIT 3) SEND CHECK DIGIT 4) CONCATENATE MODE
(ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF)
EAN
« 0)EANDECODER 1) ZERO FILL EAN-8 TO EAN-13 « 2)SENDEAN-13COUNTRYCODE « 3) SEND EAN-8 COUNTRY CODE « 4) SEND EAN-13 CHECK DIGIT « 5) SEND EAN-8 CHECK DIGIT 6) ISBN CONVERSION
(ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF)
INT. 2 OF 5
« 0) I 2 OF 5 DECODER 1) CHECK DIGIT: «0=NONE 1=USS 2=OPCC 2) SEND CHECK DIGIT 3) FIXED LENGTH 4) SET FIXED LENGTH #1 5) SET FIXED LENGTH #2
(ON/OFF)
« 0) CODE 128 DECODER 1)UCC-128VERIFICATION « 2) SEND MOD 10 CHECK DIGIT
(ON/OFF) (ON/OFF) (ON/OFF)
EXIT (SAVE CHANGES)
« 0)UPCDECODER 1) CONVERT UPC-E TO UPC-A 2) CONVERT UPC-A TO EAN-13 « 3) SEND UPC-A NUMBER SYSTEM « 4) SEND UPC-E NUMBER SYSTEM « 5) SEND UPC-A CHECK DIGIT « 6) SEND UPC-E CHECK DIGIT
UPC/EAN SUPPLEMENTS
CODABAR
(ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF)
0) SUPPLEMENTS DECODER « 1) ALLOW 2 DIGIT SUPPLEMENTS « 2) ALLOW 5 DIGIT SUPPLEMENTS 3) REQUIRE UPC SUPPLEMENTS 4)REQUIRE EAN SUPPLEMENTS 5)REQUIREBOOKLANDSUPPLEMENTS 6) SEND SEPARATOR SPACE
(ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF)
« 0) CODABAR DECODER 1) SEND START/STOP 2) CLSI FORMATTING 3) CLSI CHECK DIGIT
(ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF)
« 0) CODE 93 DECODER 1) CONCATENATE MODE
(ON/OFF) (ON/OFF)CODE 93MSI/PLESSEYPREAMBLE
(ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF)
0) MSI/PLESSEY DECODER 1) TWO CHECK DIGITS REQUIRED 2) FIRST CHECK DIGIT MOD 11 3) SEND 1ST CHECK DIGIT 4) SEND 2ND CHECK DIGIT 5) ISBN PLESSEY 0) ENTER PREAMBLE 1) PREAMBLE SEND DELAY 2) ACTIVE TYPES A=C39 B=UPC-A C=UPC-E E=EAN-8 F=I 2 OF 5 G=CODABAR I =C93 J=MSI K=C11 « X=ALL
(CHART)(ON) (0.0 - 9.9 SEC) (CHART) D=EAN-13 H=C128 L=ISBN
BAR CODE OPTIONS
0) SEND BAR CODE TYPE ID « 1) DUPLICATE READS ALLOWED 2) BAR CODE FUNCTION KEYS « 3) BAR CODE SPECIAL KEYS 4) BAR CODE TERM CHAR OVERRIDE 5) KEYBOARD AUTO CAPS/NUM LOCK 6) ALTERNATE NUMERIC KEYS
(ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF)
LASER/CCD OPTIONSHOST KEYBOARD TYPE0123
CODE 11 0) CODE 11 DECODER 1) TWO CHECK DIGITS REQUIRED 2) SEND 1ST CHECK DIGIT 3) SEND 2ND CHECK DIGIT
POSTAMBLE
BAR CODE EDIT
(ON/OFF) (ON/OFF) (ON/OFF) (ON/OFF)
(CHART)(ON) 0) ENTER POSTAMBLE (0.0 - 9.9 SEC) 1) POSTAMBLE SEND DELAY (CHART) 2) ACTIVE TYPES A=C39 B=UPC-A C=UPC-E D=EAN-13 E=EAN-8 F=I2OF5 G=CODABAR H=C128 I =C93 J=MSI K=C11 L=ISBN « X=ALL (ON/OFF) 0) BAR CODE EDITING (0 - 9, A-F) 1) ENTER # OF LEADING CHARS TO STRIP (0 - 9, A-F) 2) ENTER # OF TRAILING CHARS TO STRIP (CHART) 3) ENTER BAR CODE TYPE TO EDIT: A=C39 B=UPC-A C=UPC-E D=EAN-13 E=EAN-8 F=I 2 OF 5 G=CODABAR H=C128 « X=ALL I =C93 J=MSI K=C11 (ON/OFF) 4) STRIP LEADING & TRAILING SPACES
4567TERMINATION CHARACTER
0)LASERTRIGGERMODE: (0-3) «0=TRIGGER MODE 1=PULSE MODE 2=CONTINUOUS MODE 3=BLINK MODE (0-9 SEC) 1)LASER/CCDTIMEOUT (0.0-9.9 SEC) 2) READ DELAY (0-9) 3) READ VERIFICATION
0)NONE 1) HORIZONTAL TAB « 2)CARRIAGE RETURN 3) CARRIAGE RETURN & LINE FEED 4)USERDEFINEDTERMINATIONCHAR. 5) NUMERIC KEY PAD ENTER
(CHART) (ON/OFF)8HOST TRANSMIT SPEED
«0) USA (ENGLISH) 1) FRENCH 2)GERMAN 3) ITALIAN 4) UNIVERSAL
0) SLOW 1) MEDIUM SLOW 2) MEDIUM FAST «3) FAST
9
PORTABLE ID ADDRESS
HOST ID ADDRESS « 1 HOST UNIT ID
DIAGNOSTICS
UPC
(ON/OFF) (ON/OFF) (02 - 60) (02 - 60)
CODE 128SCAN BEEP(VERSION 1.7)
1) SCAN START TO PUT THE READER IN PROGRAM MODE. 2) SCAN THE CATEGORY BAR CODE (i.e.CODE 39, BAR CODE EDIT). 3) SCAN THE OPTION (0-9) NUMBER AND USE A-F FOR NUMBERS 10-15. 4) IF OPTION TYPE (ON/OFF) THEN SCAN EITHERON OR OFF. IF OPTION TYPE (CHART) THEN SCAN FROMFULL ASCII CHART. 5) AFTER COMPLETING ALL CHANGES, SCANEXIT (SAVE CHANGES).
LENGTH
(0 - 7)
0) SHORT « 1)MEDIUMSHORT 2) MEDIUM LONG 3)LONG 8) OFF
TONE
4) LOW 5) MEDIUM LOW « 6) MEDIUM HIGH 7)HIGH
PERFORMS A SELF-TEST AND SENDS THE STATUS TO THE HOST.
« 1 PORTABLE UNIT ID
(0-9)
PORTABLE ACKNOWLEDGE BEEP LENGTH
ON
TONE
« 0) SHORT 3) LOW 4)MEDIUM 1) MEDIUM «5)HIGH 2 ) LONG 6) NUMBER OF BEEPS «2
(0-2)
PORTABLE SHUTDOWN TIME «10 MINUTES
OFF (00-99)(00= NO SHUTDOWN)EXIT (IGNORE CHANGES)
« INDICATES DEFAULT SETTING. NOTES: 1) SCAN OPTION 9 TO RESET ALL CURRENTCATEGORY OPTIONS TO DEFAULT. 2) SCAN ON WHEN FINISHED SCANNING PREAMBLE & POSTAMBLE CHARACTERS. 3) ALL DELAY & FIXED LENGTH ENTRIES REQUIRE SCANNING TWO DIGITS. 4) CONTINUOUS & BLINK MODE OPTIONS NOT AVAILABLE ON THE M6000. WHEN ENABLED ON THE M6200, RF COMMUNICATIONS ARE DISABLED.
RESET ALL DEFAULTS
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
SP0@P`pSOH ( )➞DC1 (F1)!1AQaqSTX (➞)DC2 (F2)"2BRbr➞
FULL ASCII CHART DLE (INS)
ETX ( )DC3 (F3)#3CScsEOT ( )➞DC4 (F4)$4DTdtENQ (HOME)NAK (F5)%5EUeuACK (END)SYN (F6)&6FVfvBEL (DEL)ETB (F7)'7GWgwBSCAN (F8)(8HXhxHTEM (F9))9IYiyLFSUB (F10)*
- J