Page 37
CODABAR 0) CODABAR DECODER ON * Enable reading CODABAR labels. OFF
Disable reading CODABAR labels.
1) SEND START/STOP ON Transmit the CODABAR start/stop characters. OFF *
Do not transmit the CODABAR start/stop characters.
2) CLSI FORMATTING ON The reader will insert a blank after the 1st, 5th, and 10th characters of a 14-character CODABAR label. The label length does not include the start and stop characters. OFF *
Disable CLSI formatting.
3) CLSI CHECK DIGIT ON Enable the CLSI check digit. When this option is enabled, all fourteen digit numeric bar codes must contain a valid check digit. OFF*
Disable the CLSI check digit. Check digit verification will not be performed.
CODE 128 0) CODE 128 DECODER ON * Enable reading Code 128 labels. OFF
Disable reading Code 128 labels.
1) UCC-128 VERIFICATION ON A valid MOD 10 CHECK DIGIT is required on UCCMOD 10 bar codes. (Applies to 20-digit serial shipping container bar codes.) OFF *
UCC-MOD 10 bar codes are accepted without valid MOD 10 CHECK DIGITS.
2) SEND MOD 10 CHECK DIGIT ON * Transmit the MOD 10 CHECK DIGIT with the bar code entry. OFF
Do not transmit the MOD 10 CHECK DIGIT.
33
Page 38
CODE 93 0) CODE 93 DECODER ON* Enable reading Code 93 labels. OFF
Disable reading Code 93 labels.
1) CONCATENATE MODE ON Enable CONCATENATE MODE. The concatenate mode allows the reader to concatenate multiple bar codes in its buffer, then send them to the computer just like they were a single bar code. When a Code 93 label with a leading space is read, the reader emits two short beeps and buffers the data without transmission. This process continues until a Code 93 label without a leading space is read or 128 characters are buffered. A Code 93 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer.
CODE 11
OFF*
Disable CONCATENATE MODE.
0) CODE 11 DECODER ON Enable reading CODE 11 labels. OFF *
Disable reading CODE 11 labels.
1) TWO CHECK DIGITS REQUIRED ON Two valid CHECK DIGITS are required for each label. OFF *
One valid CHECK DIGIT is required for each label.
2) SEND FIRST CHECK DIGIT ON Transmit the FIRST CHECK DIGIT. OFF *
Do not transmit the FIRST CHECK DIGIT.
3) SEND SECOND CHECK DIGIT ON Transmit the SECOND CHECK DIGIT. OFF *
Do not transmit the SECOND CHECK DIGIT.
34
Page 39
MSI/PLESSEY 0) MSI/PLESSEY DECODER ON Enable reading MSI/PLESSEY labels. OFF *
Disable reading MSI/PLESSEY labels.
1) TWO CHECK DIGITS REQUIRED ON Two valid CHECK DIGITS are required for each label. The first check digit is defined by option (2) below. The second check digit is always MOD 10. OFF *
One valid CHECK DIGIT is required for each label. The CHECK DIGIT must be MOD 10.
2) FIRST CHECK DIGIT MOD 11 ON The FIRST CHECK DIGIT must be MOD 11. OFF *
The FIRST CHECK DIGIT must be MOD 10.
3) SEND FIRST CHECK DIGIT ON Transmit the FIRST CHECK DIGIT. OFF *
Do not transmit the FIRST CHECK DIGIT.
4) SEND SECOND CHECK DIGIT ON Transmit the SECOND CHECK DIGIT. OFF *
Do not transmit the SECOND CHECK DIGIT.
5) ISBN PLESSEY ON Enable reading of Modified Plessey ISBN bar codes. Only eleven digit ISBN bar codes will be read. OFF*
Do not read Modified Plessey ISBN bar codes.
35
Page 40
SERIAL PORT The RS-232C serial port transmits and receives data from both the host computer and the terminal. The reader's serial port parameters must match those of the terminal. 0) DATA TYPE: 0=ASCII 1=PC SCAN CODES 0* Sets the data format to ASCII characters. Use this mode with standard ASCII terminals. 1
Sets the data format to PC SCAN CODES. Use this mode only if you are using a "PC-Terminal" type terminal. This type of terminal transmits PC SCAN CODES to the host computer. Some operating systems that use these types of terminals are: PCMOS, CONCURRENT DOS, etc.
1) DUPLEX MODE: 0=FULL 1=HALF 0* Selects FULL DUPLEX mode. In FULL DUPLEX, the reader transmits data out the HOST port only. The host computer receives the data and echoes it back to the terminal. 1
Selects HALF DUPLEX mode. In HALF DUPLEX, the readers transmits data out both the HOST and TERMINAL ports at the same time.
2) INTERCHARACTER DELAY (00 - 99 msec) This option specifies the amount of delay to be inserted after transmitting each character. The delay period is programmable from 00 to 99 msec. This feature allows the user to slow the data rate down for host computers that require more time to process each character. 3) DAISY CHAIN (ON/OFF, ID) This option specifies the Daisy Chain mode of operation. ON
Enables Daisy Chain Controller operation. When enabled, the unit polls and accepts data from each M2500 that is in the daisy chain.
OFF*
Disables all Daisy Chain operations. operates as a stand alone unit.
ID
Designates the unique daisy chain ID. Accepts ID values from the Full ASCII Chart in the range of "SP" to "DEL" (ASCII 32-127).
36
M2500
Page 41
4) SEND DAISY CHAIN ID (ON/OFF) ON
Sends the daisy chain ID at the beginning of data transmit, when in the daisy chain mode.
OFF*
Does not send daisy chain ID.
5) HOST RESPONSE (ON/OFF) ON
Unit requires receipt of a Host Response after each data transmit. When used during daisy chain mode, the command must be preceeded by the daisy chain ID.
OFF*
Unit does not require a Host Response. Valid Host Responses are: CTRL G (ASCII 7) CTRL R (ASCII 18) CR (ASCII 13) -
Single Beep. High/Low warble tone. Data OK. No action needed.
6) HOST RESPONSE TIMEOUT (00-99 SEC) This parameter specifies how long the M2500 will wait for the host response. If the response timeout is set to zero then the M2500 will wait indefinitely. If a response is not received within the timeout period, the M2500 will continue scanning. The host response delay is programmable from 0-99 seconds. 7) HOST BEEP ENABLE (ON/OFF) ON
Enables receipt of commands from the Host Computer. These commands can be sent at any time. CTRL G (ASCII 7) CTRL R (ASCII 18)
OFF*
-
Single Beep. High/Low warble tone.
Disables Host Commands.
37
Page 42
BAUD RATE The baud rate sets the data transmission speed for the serial interface port on the reader. The reader’s baud rate must match the terminal. Select one of the following: 0) 1) 2) 3) 4) 5) 6)* 7) 8)
150 300 600 1200 2400 4800 9600 19,200 38,400
PARITY Sets the parity for the serial interface data. This setting must match the terminal. Select one of the following: 0)* 1) 2) 3)
NONE EVEN ODD MARK
DATA BITS Sets the character length (number of data bits per character) for the serial interface data. This setting must match the terminal. Select one of the following: 0) 1)*
7 BITS 8 BITS
38
Page 43
PREAMBLES PREAMBLE refers to a user-defined set of characters transmitted at the beginning of each type of input data. There are two different preambles. One set for bar code data, and one set for magnetic stripe data. 0) ENTER BAR CODE PREAMBLE This set of user-defined characters is transmitted at the beginning of bar code data. To define this preamble, scan up to 15 characters from the FULL ASCII section of the MENU and then scan the "ON" bar code when you are done. 1) ENTER MAG STRIPE PREAMBLE This set of user-defined characters is transmitted at the beginning of magnetic stripe data. To define this preamble, scan up to 15 characters from the FULL ASCII section of the MENU and then scan the "ON" bar code when you are done. 2) BAR CODE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the bar code preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 3) MAG SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the mag stripe preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 4) ACTIVE TYPES Specifies the types of bar codes that use preambles. Select one of the following: A CODE 39 B UPC-A C UPC-E D EAN-13 E EAN-8 F INTERLEAVED 2 of 5 X* ALL BAR CODES
39
G CODABAR H CODE 128 I CODE 93 J MSI/PLESSEY K CODE 11 L ISBN
Page 44
POSTAMBLES POSTAMBLE refers to a user-defined set of characters transmitted at the end of each type of input data. There are two different postambles. One set for bar code data, and one set for magnetic stripe data. 0) ENTER BAR CODE POSTAMBLE This set of user-defined characters is transmitted at the end of bar code data. To define this postamble, scan up to 15 characters from the FULL ASCII section of the MENU and then scan the "ON" bar code when you are done. 1) ENTER MAG STRIPE POSTAMBLE This set of user-defined characters is transmitted at the end of mag stripe code data. To define this postamble, scan up to 15 characters from the FULL ASCII section of the MENU and then scan the "ON" bar code when you are done. 2) BAR CODE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the bar code postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 3) MAG SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the mag stripe postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 4) ACTIVE TYPES Specifies the types of bar codes that can accept appended postambles. Select one of the following: A CODE 39 B UPC-A C UPC-E D EAN-13 E EAN-8 F INTERLEAVED 2 of 5 X* ALL BAR CODES
40
G CODABAR H CODE 128 I CODE 93 J MSI/PLESSEY K CODE 11 L ISBN
Page 45
TERMINATION CHARACTER The optional TERMINATION CHARACTER is transmitted at the end of the data. This option applies to bar code, mag stripe, and serial data. If a USER DEFINED TERMINATION CHARACTER is desired, select setting (4) below, then scan a single character from the FULL ASCII section of the MENU. 0) 1) 2)* 3) 4)
NONE HORIZONTAL TAB (ASCII 09) CARRIAGE RETURN (ASCII 13) CARRIAGE RETURN & LINEFEED (ASCII 13 & ASCII 10) USER DEFINED TERMINATION CHARACTER
BEEP LENGTH & TONE Settings (0-3) set the LENGTH of the BEEP. Settings (4-7) set the TONE (pitch) of the BEEP. Setting (8), when selected, will override the other BEEP selections and shut off the BEEP.
LENGTH: 0) 1)* 2) 3)
TONE: 4) 5) 6)* 7)
OFF: 8)
SHORT MEDIUM SHORT MEDIUM LONG LONG
LOW MEDIUM LOW MEDIUM HIGH HIGH
NO BEEP
41