Page 28
PREAMBLES
SERIAL PORT DATA TYPE DUPLEX MODE INTER-CHARACTER DELAY DAISY CHAIN SEND DAISY CHAIN ID HOST R ESPONSE HOST RESPONSE TIMEOUT HOST BEEP ENABLE BAUD RATE DATA BITS PARITY
ASCII FULL 0 MSEC OFF OFF OFF 0 SEC OFF 9600 8 NONE
NONE NONE 0 SEC 0 SEC ALL
MAG STRIPE #1 SEND ACCOUNT NUMBER SEND NAME (TRACK 1 ONLY) SEND EXPIRATION DATE SEND ALL TRACK DATA ENTER TRK 1 S EP CH FORMAT EXP. DATE MMYY ENTER TRKS 2&3 SEP CH
TERMINATION CHARACTER BEEP
MEDIUM SHORT MEDIUM HIGH
BAR CODE EDIT BAR CODE EDITING ENTER # OF LEADING STRIP CHAR'S ENTER # OF TRAILING STRIP CHAR'S ENTER B AR CODE TYPE TO EDIT STRIP LEADING & TRAILING SPACES
ON ON ON ON ^ OFF =
OFF 0 0 ALL OFF
BOTH OUTPUT REQUIRE TWO TRACKS OFF SEND START & END SENTINELS ON BETWEEN TRACKS/FIELDS TERM CHAR OFF SEND ENDING TERMINATION CHAR ON ON STRIP SPACES OPTIONS # 2
OFF ON 1 SEC ON OFF 1 SEC OFF ON
BAR CODE SPECIAL KEYS KEYBOARD N UM LOCK S TATUS MAG STRIPE S PECIAL/FUNCTION KEYS BAR CODE TERM CHAR OVERRIDE
DIAGNOSTICS DIAGNOSTIC SELF TEST
CR
MAG STRIPE #2
OPTIONS # 1 SEND BAR CODE TYPE ID DUPLICATE R EADS ALLOWED LASER/CCD TIMEOUT LASER/CCD TRIGGER SHUTOFF LASER/CCD CONTINUOUS R UN CONTINUOUS RUN READ DELAY BAR CODE FUNCTION KEYS KEYBOARD CAPS LOCK STATUS
NONE NONE 0.0 SEC 0.0 SEC ALL
TERMINATION CHARACTER
LENGTH TONE
POSTAMBLES BAR CODE P OSTAMBLE MAG S TRIPE POSTAMBLE BAR CODE SEND DELAY MAG STRIPE SEND DELAY ACTIVE
ENTER BAR CODE P REAMBLE ENTER MAG STRIPE PREAMBLE BAR CODE SEND DELAY MAG STRIPE SEND DELAY ACTIVE
OFF
24
OFF OFF OFF OFF
Page 29
CHANGING THE DEFAULT SETTINGS You can easily change the default settings by simply scanning the bar code options located on the READER SETUP MENU. The READER SETUP MENU is a laminated sheet of bar codes supplied with this manual. The basic programming sequence is: START / CATEGORY / OPTION (0-9) / ON/OFF (or) NUMBER ONLY / EXIT Follow the instructions below to change the settings. Step 1:
Scan the START label at the top left corner of the SETUP MENU. This puts the reader into the program mode.
Step 2:
Scan one of the CATEGORY labels (i.e. Code 39, UPC, Baud Rate).
Step 3:
Select the desired option by scanning one of the numeric labels (0 - 9).
Step 4:
If there is an (ON/OFF) next to the description, scan an ON label to enable or OFF label to disable the option. EXAMPLE: To enable the MOD 43 check digit on Code 39, perform the following: 1) 2) 3)
Scan the "CODE 39" category label. Scan option "2" label to select "MOD 43 CHECK DIGIT" option. Scan the "ON" label to enable it.
If there is a range of numbers next to the option, then scan one of the numeric labels (0 -9). EXAMPLE: To select the OPCC check digit for Interleaved 2 of 5, perform the following: 1) Scan the "INT. 2 of 5" category label. 2) Scan the "1" label to select the "CHECK DIGIT" option. 3) Scan the "2" label to select OPCC.
25
Page 30
Step 5:
If you want to make another change within the SAME CATEGORY, you can scan another option number (i.e., return to Step 3 above). If you want to make a change in a DIFFERENT CATEGORY you MUST scan the new CATEGORY (i.e., return to Step 2 above and repeat the steps).
Step 6:
When you have finished making all of the changes, you can either: 1)
2)
SCAN the EXIT changes
(Save Changes)
label to save all the
OR
SCAN the EXIT (Ignore Changes) label to exit without saving any changes. NOTE:
You can reset the reader to the default settings by performing the following: 1) Scan the START label. 2) Scan the RESET ALL DEFAULTS label. 3) Scan the EXIT (Save Changes) label.
26
Page 31
PROGRAMMING GUIDE
START The START bar code places the reader into the program mode. After scanning this label, the reader will emit three short BEEPS to indicate that it is in the program mode. EXIT (SAVE CHANGES) Scan this bar code to EXIT the program mode and save all of the changes. After scanning this label, the reader will BEEP twice then delay approximately one second and emit three short BEEPS to indicate that it accepted the changes. EXIT (IGNORE CHANGES) Scan this bar code to EXIT the program mode and DISCARD all of the current changes. The reader will use the settings that were in effect before entering the program mode. RESET ALL DEFAULTS Scan this bar code to RESET all options to their DEFAULT settings. NOTE: Defaults are marked with "*". 0-9 BAR CODES These bar codes are scanned to select various options and enter programmable data into the reader. NOTE: Scan option (9) to reset all of the options within the current CATEGORY back to their defaults. ON
OFF
If the OPTION has an (ON/OFF) beside the description, scan the ON bar code to turn ON the current option. If the OPTION has an (ON/OFF) beside the description, scan the OFF bar code to turn OFF the current option.
FULL ASCII CHART The FULL ASCII CHART is located on the back of the READER SETUP MENU. This chart contains the entire ASCII character set (128 characters). Use this chart to enter PREAMBLE and POSTAMBLE character strings as well as the RECORD TERMINATOR and SEPARATOR characters. ADDITIONAL NOTES: If the description beside the OPTION contains: (ON/OFF) Then scan either an ON or OFF label to set the option. (CHART) Then scan one or more characters from the Full ASCII Chart. (0-9) Scan the disired character from the 0-9 labels. (0.0-9.9) Scan two characters from the 0-9 labels to set the time from 0 to or (0.0-99) 9.9 seconds, or 0 to 99 seconds.
27
Page 32
CODE 39 0) CODE 39 DECODER ON* Enable reading CODE 39 labels. OFF 1) FULL ASCII ON OFF*
Disable reading CODE 39 labels. Enable the FULL ASCII EXTENSION to CODE 39. Option #0 above must be set ON. Disable the FULL ASCII EXTENSION to CODE 39. This sets the reader to the standard CODE 39 mode.
2) MOD 43 CHECK DIGIT ON Enable the MOD 43 CHECK DIGIT for CODE 39. When this option is enabled, only CODE 39 labels that contain a valid check digit will be read. OFF*
Disable the MODE 43 CHECK DIGIT. verification will not be performed.
Check digit
3) SEND CHECK DIGIT ON Transmit the MOD 43 CHECK DIGIT with the bar code data. Requires option #2 above to be set ON. OFF*
Do not transmit the MOD 43 CHECK DIGIT.
4) CONCATENATE MODE ON Enable CONCATENATE MODE. The concatenate mode allows the reader to accumulate multiple bar codes in its buffer, then send them to the computer just like they were a single bar code. When a Code 39 label containing a leading space is read, the reader emits two short beeps and buffers the data without transmission. This process continues until a Code 39 label without a leading space is read or 128 characters are buffered. A Code 39 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer. OFF*
Disable CONCATENATE MODE.
28
Page 33
UPC 0) UPC DECODER ON* Enable reading UPC-A and UPC-E labels. OFF
Disable reading UPC-A and UPC-E labels.
1) CONVERT UPC-E TO UPC-A ON Convert all UPC-E labels to their UPC-A equivalents before transmission. After conversion, the reader will follow the UPC-A programming options. OFF*
No conversions will be performed.
2) CONVERT UPC-A TO EAN-13 ON Convert all UPC-A labels to an equivalent EAN-13 format by inserting a leading zero. After conversion, the reader will follow the EAN-13 programming options. OFF*
No conversions will be performed.
3) SEND UPC-A NUMBER SYSTEM ON* Transmit the UPC-A NUMBER SYSTEM character. OFF
Do not transmit the UPC-A NUMBER SYSTEM character.
4) SEND UPC-E NUMBER SYSTEM ON* Transmit the UPC-E NUMBER SYSTEM character. OFF
Do not transmit the UPC-E NUMBER SYSTEM character.
5) SEND UPC-A CHECK DIGIT ON* Transmit the UPC-A CHECK DIGIT character. OFF
Do not transmit the UPC-A CHECK DIGIT character.
6) SEND UPC-E CHECK DIGIT ON* Transmit the UPC-E CHECK DIGIT character. OFF
Do not transmit the UPC-E CHECK DIGIT character.
29
Page 34
EAN 0) EAN DECODER ON* Enable reading EAN-8 and EAN-13 labels. OFF
Disable reading EAN-8 and EAN-13 labels.
1) ZERO FILL EAN-8 TO EAN-13 ON Add five leading zeroes to EAN-8 labels. After conversion, the reader will follow the EAN-13 programming options. OFF*
No conversion is performed.
2) SEND EAN-13 COUNTRY CODE ON* Transmit the EAN-13 COUNTRY CODE. OFF
Do not transmit the EAN-13 COUNTRY CODE.
3) SEND EAN-8 COUNTRY CODE ON* Transmit the EAN-8 COUNTRY CODE. OFF
Do not transmit the EAN-8 COUNTRY CODE.
4) SEND EAN-13 CHECK DIGIT ON* Transmit the EAN-13 CHECK DIGIT character. OFF
Do not transmit the EAN-13 CHECK DIGIT character.
5) SEND EAN-8 CHECK DIGIT ON* Transmit the EAN-8 CHECK DIGIT character. OFF
Do not transmit the EAN-8 CHECK DIGIT character.
6) ISBN CONVERSION ON Convert 13 DIGIT BOOKLAND/EAN (978 prefix) to its corresponding 10 DIGIT ISBN number. EXAMPLE: BAR CODE DATA = 9780806957906 ISBN OUTPUT DATA = 0806957905 OFF*
Do not convert Bookland/EAN to an ISBN number.
30
Page 35
UPC/EAN SUPPLEMENTS 0) SUPPLEMENTS DECODER ON Enable reading UPC & EAN supplements. OFF*
Disable reading UPC & EAN supplements.
1) ALLOW 2 DIGIT ON* Enable reading 2 digit supplements. Option 0 above must be set ON. OFF
Disable reading 2 digit supplements.
2) ALLOW 5 DIGIT ON* Enable reading 5 digit supplements. Option 0 above must be set ON. OFF
Disable reading 5 digit supplements.
3) REQUIRE SUPPLEMENTS Specifies how the reader will handle various supplements. 0)* UPC/EAN bar codes will be read with or without valid supplements. 1) UPC bar codes will not be read unless they are accompanied by a valid supplement. 2) EAN bar codes will not be read unless they are accompanied by a valid supplement. 3) Bookland EAN bar codes will not be read unless they are accompanied by a valid supplement. 4) All UPC/EAN bar codes will not be read unless they are accompanied by a valid supplement. 4) SEND SEPARATOR SPACE ON Insert a space between the standard bar code data and the supplemental data. OFF*
No separator space is inserted.
31
Page 36
INTERLEAVED 2 OF 5 0) I 2 OF 5 DECODER ON* Enable reading INTERLEAVED 2 of 5 labels. OFF
Disable reading INTERLEAVED 2 of 5 labels.
1) CHECK DIGIT: 0=NONE, 1=USS, 2=OPCC Specifies which type of check digit will be used with INTERLEAVED 2 of 5: 0* = NONE (no check digit required) 1 = UNIFORM SYMBOLOGY SPECIFICATION (3-1-3 MOD 10) 2 = OPTICAL PRODUCT CODE COUNCIL (2-1-2 MOD 10) 2) SEND CHECK DIGIT ON Transmit the INTERLEAVED 2 of 5 check digit with the bar code data. OFF*
The check digit is not transmitted.
3) FIXED LENGTH ON Read only FIXED LENGTH INTERLEAVED 2 of 5 bar code labels that match the lengths defined in options #4 & #5 below. The check digit can be on or off. OFF*
Disable FIXED LENGTH mode. Read all INTERLEAVED 2 of 5 labels without regard to length.
4) SET FIXED LENGTH #1 (02-60) Sets the first valid FIXED LENGTH for Interleaved 2 of 5. Scan a two digit value to enter the length. Valid lengths are 02 to 60 characters. By definition, the length of Interleaved 2 of 5 labels are an even number of characters. The default FIXED LENGTH is 6 characters. 5) SET FIXED LENGTH #2 (02-60) Sets a second valid fixed LENGTH for Interleaved 2 of 5. Scan a two digit value to enter the length. The default length is set to 0 characters (i.e. the second FIXED LENGTH is disabled).
32