Page 215

AT-WA7500 and AT-WA7501 Installation and User’s Guide

8. Click Submit Changes to save your changes. To activate your changes, from the menu bar click Save/Discard Changes, and then click Save Changes and Reboot. For help, see “Saving Configuration Changes” on page 45.

Configuring the Database

The EAS database contains up to 128 clients that this access point authorizes for logins, RADIUS clients, ACL clients, and 802.1x clients. This screen is hot settable; that is, to activate a change, you click Save/ Discard changes, and then click Save Changes without Reboot. You can also create a database (using Microsoft Excel or Notepad) and then import it. Or you can configure one database, export it, and import it to an EAS in another RADIUS server. For help, see “Exporting and Importing Databases” on page 219. Note Allied Telesyn recommends that when you are done configuring the database, you export it and save the file in a safe place. If you restore the access point to its default configuration, the database is not saved. For help, see “Exporting and Importing Databases” on page 219. To configure the database 1. Log in to the access point whose EAS you are using.

215

Page 216

Chapter 7: Configuring the Embedded Authentication Server (EAS)

2. From the main menu, click Security > Embedded Authentication Server > Database. The Database screen appears.

3. In the Type field, choose the type of client you are entering in the database. For help, see the next table. 4. Click Submit Changes to save your changes. 5. Enter the appropriate user name and password, if applicable. User names and passwords can be from 1 to 32 characters. For help, see the next table. 6. Click Submit Changes to save your changes. 7. Repeat Steps 3 through 6 for each client.

216

Page 217

AT-WA7500 and AT-WA7501 Installation and User’s Guide

8. Click Save/Discard changes, and then click Save Changes without Reboot. Table 3. Embedded Authentication Server Entry Descriptions Type Field

Description

User Name Field

Password Field

Login

Enter user names and passwords for users who are authorized to configure and maintain access points using the password server.

User name

User password

RADIUS

Enter a secret key that is shared by the RADIUS client (access point) and the RADIUS server.

RADIUS client IP address

Secret key

You do not need to enter any RADIUS clients if you do not change the default secret key. For more security, you should change the default secret key. ACL

Enter the end device radio MAC address for all end devices that are authorized to communicate with the network.

MAC address

None

802.1x (TTLS/ PEAP)

Enter the login name and password of all end devices that are authorized to communicate with the 802.1x-enabled network.

End device login name

End device login password

Client certificate common name

None

For more security, you should delete the user name “anonymous” and the password “anonymous.” 802.1x (TLS)

Enter the client certificate common name of all end devices that are authorized to communicate with the 802.1x-enabled network.

217

Page 218

Chapter 7: Configuring the Embedded Authentication Server (EAS)

Using the Rejected List

The Rejected List screen displays the users and devices that have been rejected by the EAS. You can use this list to discover which users and devices may need to be added to the database. When using the web browser interface, you can immediately add previously rejected end devices to the database. You do not need to click Submit Changes or reboot the access point. Note When you reboot the access point, the rejected list is cleared. To view the rejected list 1. Log in to the access point whose EAS you are using. 2. From the main menu, click Security > Embedded Authentication Server > Rejected List. The Rejected List screen appears. 3. Determine which users and devices you need to add to the database. For help understanding the list, see the next table. 4. Add users and devices to the database. For help see “Adding Entries to the Database” on page 218. Table 4. Rejected List Values Column

Description

Type

Lists the type of authentication that failed. The type can be: Login, ACL, TTLS/PAP, TTLS/CHAP, TTLS/EAP, TTLS/MSCHAP, TTLS/MSCHAP-V2, PEAP/MSCHAPV2, PEAP/GTC, or TLS.

User Name

Lists the value that was passed in the User Name field of the RADIUS server database during the failed attempt.

Last Time

Indicates how long ago the last authentication was attempted.

Count

Indicates how many times the authentication failed.

NAS IP Address

Displays the IP address of the RADIUS server that rejected the client.

Adding Entries to the Database When you accept TTLS/PAP and PEAP/GTC entries, they are added to the database and require no further configuration. If the authentication type does not allow the EAS to learn the password of the rejected client (such as TTLS/CHAP), only the user name is added to 218

Page 219

AT-WA7500 and AT-WA7501 Installation and User’s Guide the database. You need to manually enter the password into the database, click Submit Changes > Save/Discard Changes > Save Changes without Reboot. To add all entries to the database 1. Click Select All Entries. A check box appears next to all entries. 2. Click Accept Selected Entries. To add one entry to the database 1. Check the check box next to the entry you want to add to the database. 2. Click Accept Selected Entries.

Clearing the Rejected List To clear the rejected list, you can either reboot the access point or perform these steps. 1. Click Select All Entries. A check box appears next to all entries. 2. Click Clear Selected Entries.

Exporting and Importing Databases

Note Allied Telesyn recommends that you use the secure web browser interface (HTTPS) when you export and import databases. Otherwise, the information in the databases is sent in the clear. The EAS database is simply a comma-separated text file. You can create the database offline (using Microsoft Excel or Notepad) and then import it. The file must have the following format: ACL, 11-22-33-44-55-66 TTLS, username, password TLS, commonname LOGIN, username, password RADIUS, 0.0.0.0, secretkey

Note PEAP entries are imported and exported as TTLS entries, since they require the same parameters.

219

Page 220

Chapter 7: Configuring the Embedded Authentication Server (EAS)

You should export the database so you have a backup version. You may also want to create the database in the primary RADIUS server, and then export it to a file that you can import to a backup RADIUS server. To export a database 1. Log in to the access point whose EAS you are using. 2. From the menu bar, click File Import/Export > Read or write the EAS RADIUS database. The EAS Database Import/Export screen appears. 3. If you are not using the secure web browser, click “A secure session is available.” Repeat Steps 1 and 2.

4. Click Export the EAS database from this access point. A File Download dialog box appears.

220

Page 221

AT-WA7500 and AT-WA7501 Installation and User’s Guide

5. Make sure Save this file to disk is selected, and then click OK. The Save As dialog box appears.

6. Choose the location and filename of the database. If you use the *.CSV extension, you can import it into Microsoft Excel, which recognizes it as a comma separated text file. 7. Click Save. To import a database Note As soon as you import the database, it is active. 1. Log in to the access point whose EAS you are using. 2. From the menu bar, click File Import/Export > Read or write the EAS RADIUS database. The EAS Database Import/Export screen appears.

221

Page 222

Chapter 7: Configuring the Embedded Authentication Server (EAS)

3. If you are not using the secure web browser, click A secure session is available. Repeat Steps 1 and 2. 4. Enter the path and filename of the database. Or click Browse to locate the file. 5. Click Import Database.

222