Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 14

MobileView Tablet T750 User Manual: Chapter 4

Pages 45 to 54 of 104, from MobileView Tablet T750 User Manual

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley T750

Page 45

Chapter

4

Power Management

Introduction

Keeping the MobileView Tablet supplied with power is extremely important. The data, customized settings, and files you save on the Tablet are stored in RAM. If the power is not managed properly, stored information may be lost. Tablet settings and files may also be saved to the Flash storage card to avoid loss during a power failure. See 3 for more information. If the Tablet detects a power fault during operation, it performs a graceful shutdown. The internal backup battery maintains power to retain your data for up to two minutes if the main battery pack is removed or runs out of power. To avoid losing data, connect to an external power source and recharge the battery or replace the main battery pack as soon as possible. You can recharge the battery as instructed on page 4-5. You can also remove and replace the battery pack with a fully charged battery as instructed in Replacing the Main Battery Pack on page 4-7.

TIP

1

The Windows CE operating system and standard programs installed on the Tablet are stored in Flash Memory and cannot be erased or lost.

Publication 2727-UM001D-EN-P - March 2004

Page 46

4-2

Power Management

Battery Safety WARNING

Replacing or handling the battery incorrectly may present a risk of fire or explosion, which could cause serious injury. • Only replace the main battery pack with the same type of battery, specified by Rockwell Automation (catalog number 2727-TRB7). • Do not disassemble, short-circuit, or incinerate batteries or expose them to temperatures above +60°C (+140°F). • Do not subject batteries to impact. • Do not use rusty, discolored, cracked, or otherwise damaged batteries. • Properly dispose of batteries. Check with your local solid waste officials for details about recycling options or for proper disposal in your area; or contact Rockwell Automation for instructions.

Checking the Power Level

The power level of the batteries can be checked in three different ways: • Check the five battery status LEDs at the top left corner of the Tablet case for the battery charge level (a percentage based on the main battery’s capacity). • Check the battery pack LEDs for the true power level of the main battery (you must remove the battery to view these LEDs). • Check the Tablet’s power properties, using the Control Panel, for information on the power status of both the main battery pack and backup battery.

Main Battery Status LEDs Battery Status LEDs

The Tablet can typically operate for up to 8 hours before the batteries require recharging. This operation time may vary based on Tablet settings, use, and environmental conditions. The five battery status LEDs, on the top left corner of the Tablet, indicate the main battery charge level in 20% increments. The charge level represented by the LEDS is shown in the following table.

Publication 2727-UM001D-EN-P - March 2004

Page 47

Power Management

4-3

Table 4.1 Main Battery Status LEDs Charge Level

LEDs Lit

80 to 100%

5

60 to 79%

4

40 to 59%

3

20 to 39%

2

10 to 19%

1

Less than 10%

1 (display flashes)

The Main Battery Status LEDs show the power level of the battery, based on the battery’s original capacity. Over time, the capacity of the main battery pack gradually declines and it will no longer charge to its original level. To see the true power level of the battery, you need to check the main battery pack LEDs.

Main Battery Pack LEDs Full capacity

F 3/4 1/2

Check the main battery pack LEDs by following these steps: 1. Remove the battery as instructed in Replacing the Main Battery Pack on page 4-7.

1/4 E

TEST ileV Mob

Test button iew

2. Press and release the TEST button. The current battery power level LED is displayed. 3. If the battery no longer charges to full (F) capacity, but only to 1/2 or less, you should replace the battery to avoid unexpected power loss.

Power Properties Dialog Box The power properties dialog box battery tab provides additional information about the power status of the main battery and backup battery. To check the power properties, follow this procedure: 1. Tap on the Start button. 2. From the Start menu, tap Settings, Control Panel.

Publication 2727-UM001D-EN-P - March 2004

Page 48

4-4

Power Management

3. Double-tap the Power icon to open the Power Properties dialog box: If the AC power or other external power source is plugged in, you can double-tap either the AC power icon or the battery charging icon on the task bar to display the power properties.

TIP

Battery tab Main Battery

Power status

Percentage of power left in main batteries: 88%

Percentage of power left

4. Tap the Battery tab. Check the status of the Main and Backup batteries.

Battery Status The Power Properties dialog box indicates battery status using the following terms:

Publication 2727-UM001D-EN-P - March 2004

Status

Description

Good

Battery power level is sufficient to operate the Tablet.

Low (main battery only)

Battery power level has dropped significantly. Recharge the batteries as soon as possible.

Very Low

Battery power level is at 2% or less. A notification popup appears on the screen and an audible warning will sound. Recharge the batteries immediately to avoid losing power.

Tablet powers down

Battery power level is at 1%. Recharge the batteries immediately to avoid losing data.

Charging

The main battery (left column) heading changes to read Charging when the AC power adapter is connected and the main battery is charging.

External

The main battery (left column) heading changes to read External when the main battery is not installed and the Tablet is running on external power only.

Page 49

Power Management

Managing Battery Power

4-5

Optimizing Main Battery Life Following these tips can help optimize battery life and avoid a sudden power loss: • Shorten the Suspend Timer’s time period. See Automatic Suspend Mode Operation on page 4-8. • Lower the screen brightness and use the contrast setting to increase readability. See page 3-3 to change the screen settings. • Turn off unneeded sounds or mute the audio. See page 3-17 to adjust the sounds. • Operate the Tablet with AC power connected whenever possible. See Using the AC Power Adapter/Battery Charger, below.

Using the AC Power Adapter/Battery Charger You can connect the Tablet to the 100 to 240V ac power source using the AC power adapter to operate on AC power and to charge the battery.

Power Port

The battery is fully charged (to its capacity) when the five battery LED indicators are green. Verify the percentage of battery capacity by looking at the power feature in the control panel. Tap the Start button and select Settings, Control Panel, Power. Use the AC power adapter when you: • Run the Tablet for long periods of time • Recharge the battery • Communicate with a PC

Battery Status LEDs

TIP

IMPORTANT

The Suspend Timer turns off when an external power source is connected to the Tablet, unless the timer has been enabled to remain on. Refer to Automatic Suspend Mode Operation on page 4-8.

Use only the AC adapter supplied with your MobileView Tablet. Using another type of adapter may cause a malfunction or damage the battery pack.

Publication 2727-UM001D-EN-P - March 2004

Page 50

4-6

Power Management

To charge the main battery pack, follow these steps: 1. Connect the AC adapter to the Tablet’s power port. 2. Connect the other end to the 100 to 240V ac power source. TIP

Over time, the capacity of a battery pack gradually declines. If you notice that the battery pack does not stay charged as long as expected, it is probably time to replace it with a new battery.

• To check battery capacity, see Main Battery Pack LEDs on page 4-3. • To replace the battery, see Replacing the Main Battery Pack on page 4-7.

Using the Single Battery Charging Station To charge the main battery pack without the use of the MobileView Tablet itself, you may use the single battery charging station (Allen-Bradley catalog number 2727-TRSP1). To charge the main battery pack in the single battery charging station, follow these steps: 1. Plug the battery charging station into the 100 to 240V ac power source, using the AC adapter provided with the charging station. 2. Remove the battery from the Tablet as instructed in Replacing the Main Battery Pack, on page 4-7. 3. Slide the battery, battery cover end up, into the battery charger cradle until the red light on the battery charger comes on. When the light on the battery charger turns green, the battery is finished charging. 4. Check the battery pack LEDs for the battery power level as instructed in Main Battery Pack LEDs on page 4-3, before placing the main battery into the Tablet.

Publication 2727-UM001D-EN-P - March 2004

Page 51

Power Management

4-7

Replacing the Main Battery Pack

IMPORTANT

IMPORTANT

The internal backup battery maintains power to retain your data for up to two minutes if the main battery pack is removed or runs out of power. To avoid losing data, files, or registry settings, save registry settings files and data to the storage card, connect to an external power source and recharge or replace the main battery pack immediately. See Using the AC Power Adapter/Battery Charger on page 4-5. See Saving Registry Settings and Storage Card Operations in 3.

The internal backup battery is not replaceable. It charges automatically when the Tablet is connected to AC power.

To replace the main battery pack, follow these steps: 1. Slide battery cover plate down (about one-eight of an inch).

2. Remove the battery by sliding the battery (and the cover plate) towards you (away from the case) until the battery is completely removed from the case.

3. Slide the battery into the battery compartment until the battery cover plate is flush with the Tablet case, then slide the cover plate up. You should feel the battery snap into place.

Publication 2727-UM001D-EN-P - March 2004

Page 52

4-8

Power Management

ATTENTION

Install only the battery supplied with your MobileView Tablet. Use of any other battery could result in a hazard to the operator and damage to equipment.

4. To close the battery compartment, gently slide the battery cover-plate up.

Using Suspend Mode In suspend mode, power is only supplied to the RAM to maintain its contents; no other system components are powered. Suspend mode consumes less power than the Idle or On modes.

Activating Suspend Mode Manually To activate suspend mode manually, follow these steps: 1. Tap on the Start button and select Suspend from the menu. The screen blacks-out. 2. To reactivate the Tablet and turn off the suspend mode, press any key.

Automatic Suspend Mode Operation You can save battery power and prevent unauthorized use of the Tablet by setting the Tablet to idle mode after a set period of idle time. To set the idle timer, follow these steps: 1. Tap on the Start button and select Settings, Control Panel from the menu. 2. Double-tap the Power icon to open the Power Properties dialog box: TIP

Publication 2727-UM001D-EN-P - March 2004

If the AC power or other external power source is plugged in, you can double-tap either the AC power icon or the battery charging icon to display the power properties.

Page 53

Power Management

4-9

Power Off tab

Check box Drop-down list

3. Tap the Power Off tab. 4. Tap the drop-down list and tap the desired time period. 5. If you want the automatic suspend mode to be effective when an external power source is being used, tap the check box to enable this option and select a time period in selection box located directly below the check box. 6. Tap OK to enter your settings and close the dialog box.

Publication 2727-UM001D-EN-P - March 2004

Page 54

4-10

Power Management

Publication 2727-UM001D-EN-P - March 2004