Page 71
Communications Configuration
5-17
Entering a New Static WEP Key and Enabling Static WEP Follow the steps to enter a new static WEP key for your client adapter. 1. If you entered the password correctly in the Enter Password screen, the CEM screen appears.
This screen allows you to create up to four static WEP keys. 2. For the static WEP key that you are entering (1, 2, 3, or 4), select a WEP key size of 40 or 128 on the right side of the screen. 128-bit client adapters can use 40- or 128-bit keys, but 40-bit adapters can use only 40-bit keys. If 128-bit is not supported by the client adapter, this option is grayed out, and you are unable to select it. 3. Obtain the static WEP key from your system administrator and enter it in the blank field for the key you are creating. Follow the guidelines below to enter a new static WEP key: • WEP keys can consist of the following hexadecimal characters: 0 to 9, A to F, and a to f. • WEP keys must contain the following number of characters: – 10 hexadecimal characters for 40-bit keys Example: 12345abcde – 26 hexadecimal characters for 128-bit keys Example: AB34CD78EFab01cd23ef456789 • Your client adapter’s WEP key must match the WEP key used by the access point (in infrastructure mode) or clients (in ad hoc mode) with which you are planning to communicate. • When setting more than one WEP key, the keys must be assigned to the same WEP key numbers for all devices. For example, WEP key 2 must be WEP key number 2 on all devices. When multiple WEP keys are set, they must be in the same order on all devices. TIP
After you enter a WEP key, you can write over it, but you cannot edit or delete it.
Publication 2727-UM001D-EN-P - March 2004
Page 72
5-18
Communications Configuration
4. Click the Transmit Key button to the left of the key you want to use to transmit packets. Only one WEP key can be selected as the transmit key. 5. Click OK to write your WEP key(s) to the client adapter’s volatile memory and the Windows CE registry and to exit the utility or click Cancel to exit the utility without updating the keys. 6. Double-click the Cisco ACU icon or select Start/Programs/Cisco/Aironet Client Utility. The ACU screen appears.
7. Select WEP under Property. Select Enabled from the list of options in the Value box to enable static WEP. 8. Click OK to save your changes and to exit the utility.
Overwriting an Existing Static WEP Key Follow the steps below to overwrite an existing static WEP key. 1. If you entered the password correctly in the Enter Password screen, the CEM screen appears.
A checkmark appears in the Already Set? box for all existing static WEP keys.
Publication 2727-UM001D-EN-P - March 2004
Page 73
Communications Configuration
TIP
5-19
For security reasons, the codes for existing static WEP keys do not appear on the screen. Also, you can write over existing keys, but you cannot edit or delete them.
2. Decide which existing static WEP key you want to overwrite. 3. Click within the blank field of that key. 4. Enter a new key, following the guidelines outlined in Step 3 of the “Entering a New Static WEP Key and Enabling Static WEP” section on page 4.7. 5. Make sure the Transmit Key button to the left of your key is selected, if you want this key to be used to transmit packets. 6. Click OK to write your new static WEP key to the client adapter’s volatile memory and the Windows CE registry and to exit the utility or click Cancel to exit the utility without overwriting any keys. 7. Open ACU and make sure WEP is enabled.
Changing the CEM Password Follow the steps below if you want to change the password that allows you to access CEM.
TIP
For security reasons, Cisco recommends that you change the default password.
1. Double-click the Cisco CEM icon or select Start/Programs/Cisco/Client Encryption Manager. 2. Enter the correct password in the Enter Password screen and click OK. The CEM screen appears.
Publication 2727-UM001D-EN-P - March 2004
Page 74
5-20
Communications Configuration
3. Click the Change Password button. The Change Password screen appears.
4. Enter the current password in the Existing Password field. 5. Enter a new password in the New Password Field. TIP
Passwords are case sensitive and can contain up to 256 alphanumeric characters.
6. Re-enter the new password in the Confirm New Password field. 7. Click OK to save your new password or click Cancel to exit the screen without changing the password. If your password is accepted, the following message appears, “Password Successfully Changed.” 8. Click OK to exit the utility.
Disabling Static WEP Follow the steps below if you ever need to disable static WEP. 1. Double-tap the Cisco ACU icon or select Start/Programs/Cisco/Aironet Client Utility. The ACU screen appears. 2. Select WEP under Property. Select Disabled from the list of options in the Value box to disable WEP. 3. Tap OK to save your changes and to exit the utility.
Publication 2727-UM001D-EN-P - March 2004
Page 75
Communications Configuration
Using LEAP
5-21
This section provides instructions for enabling LEAP and entering the LEAP username and password.
TIP
LEAP is supported only on client adapters that support WEP and use firmware version 4.13 or greater.
TIP
In order to use LEAP authentication, your client adapter and access point firmware must have matching 802.1X draft standards. That is, if the access point uses draft 8 firmware (prior to 11.06) or has draft 8 selected, the client adapter must use draft 8 firmware (prior to 4.25.x). Similarly, if the access point uses draft 10 firmware (11.06 or later) and has draft 10 selected, the client adapter must use draft 10 firmware (4.25.x or later).
Enabling LEAP Follow the steps below to enable LEAP for your client adapter. 1. Double-tap the Cisco ACU icon or select Start/Programs/Cisco/Aironet Client Utility. The ACU screen appears.
2. Select LEAP under Property. 3. Select Enabled in the Value box.
Publication 2727-UM001D-EN-P - March 2004
Page 76
5-22
Communications Configuration
4. Click OK to enable LEAP and exit the utility. When LEAP is enabled, the following parameters in the ACU screen are changed automatically: • WEP is set to Enabled. • Authentication Type is set to Open.
Entering the LEAP Username and Password Follow the steps below to enter the LEAP username and password. 1. WLM starts automatically whenever you start ACU with a client adapter inserted, change the LEAP parameter from Disabled to Enabled, and click OK. If LEAP is already enabled, WLM starts automatically whenever you insert the client adapter, reboot or reset the Windows CE device, or load new firmware.
TIP
You can also start WLM by selecting Start/Programs/Cisco/Wireless Login Module. You may want to do this if you inadvertently exited WLM after it started or if you roam to a different part of the network where a different login is required.
When WLM starts, the Wireless Login Module screen appears.
2. Obtain the username and password for your RADIUS server account from your system administrator. TIP
The password is optional because not all host accounts on the RADIUS server are set up with a password.
3. Enter the username in the User Name field.
Publication 2727-UM001D-EN-P - March 2004
Page 77
Communications Configuration
5-23
TIP
Usernames and passwords are case sensitive and can contain up to 32 alphanumeric characters.
TIP
If your device is running Windows CE 3.0 version 2002 and your RADIUS server account specifies a domain, enter the domain name before the username and separate the two with a forward slash (e.g. domain/username).
4. Enter the password in the Password field if the RADIUS server account for the Windows CE device was set up with a password. TIP
For security reasons, the characters entered for the password are displayed as asterisks.
5. Tap OK. If the username and password were entered correctly, they are written to volatile memory on the client adapter. The username and password remain on the client adapter until power is removed from the adapter, typically due to the client adapter being ejected or the system powering down. TIP
If a username and password are stored in the client adapter’s Flash memory from a prior release, they are erased before the new username and password are written to the adapter’s volatile memory, thereby disabling device-level LEAP.
6. One of three scenarios occurs: a. The client adapter authenticates to the RADIUS server using your username and password and receives a dynamic, session-based WEP key. The bottom of the ACU screen indicates that your client adapter is authenticated to an access point. b. If you enter the username and password incorrectly or enter ones that are not valid for the RADIUS server on the network, the Wireless Login Module screen reappears with a message indicating that your login was incorrect. You are able to retry immediately by re-entering the username and password. c. The client adapter times out while trying to authenticate, possibly because it is out of range of an access point. After 60 seconds, a message appears indicating that the first attempt to authenticate failed and that the client adapter will continue trying.
Publication 2727-UM001D-EN-P - March 2004
Page 78
5-24
Communications Configuration
TIP
During the 60 seconds before the timeout occurs, WLM is running in the background. It is hidden and does not appear as a running program. If you try to start WLM during this time, nothing happens because it is already running.
Disabling LEAP Follow the steps below if you ever need to disable LEAP. 1. Double-tap the Cisco ACU icon or select Start/Programs/Cisco/Aironet Client utility. The ACU screen appears. 2. Select LEAP under Property. 3. Select Disabled in the Value box. 4. Click OK to disable LEAP and to exit the utility.
Personal Computer Serial Communications
Publication 2727-UM001D-EN-P - March 2004
Minimum Personal Computer Requirements • Microsoft Windows NT Workstation 4.0 (Service Pack 3 or greater) or Windows 95, Windows 98/98SE, Windows 2000 (Professional version), Windows ME. • Pentium processor • 16 MB memory for Windows 95 or Windows 98 32 MB memory for Windows NT or Windows ME 64 MB memory for Windows 2000 • 10 to 50 MB available hard disk space • 9 or 25 pin available communications port • One CD-ROM drive • VGA graphics card • Keyboard • Mouse or compatible pointing device