The text of a manual · part 21 of 34
PHOTOSWITCH Photoelectric Sensors, pages 199 to 208
Pages 199 to 208 of 334
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 42SRP and Allen-Bradley 42SRU
Page 199
PHOTOSWITCHR Photoelectric Sensors
22ZC Zone Controller System Overview for Pneumatically Driven Conveyor Systems Install one 22ZC in each zone of the conveyor and attach a suitable sensing and actuating device. Note that the infeed module (22ZC--343) must be installed at the beginning of your zone control system (zone 4 on Figure 1 on page 1--182) and the master module (22ZC--413) at the discharge end of your system (zone 1 on Figure 1). Size, cut and install the flat media between each controller. Connect a suitable 24V DC power supply to any controller within the system. It is recommended to make this connection to the center controller for balanced power distribution. A 4 A power supply will provide power for up to 25 zones when using a 1 W pneumatic valve. Wire the infeed and discharge zone external connection as required using the wiring diagram shown on Figure 1. Loading Product Onto the Conveyor (Figure 2 on page 1--182) With power applied to the system, all zones will immediately drive feeding product onto the conveyor. As product passes the sensor mounted at the infeed zone, a gap will be formed equal to the zone length. This will ensure zero pressure throughout the whole system. Once the first product reaches the discharge zone (zone 1), it will stop and await release from the conveyor. Release of Product Once the product has been transported and accumulated at the discharge end of the conveyor (zone 1) it may be release in one of two manners: Singulation Release (Figure 3 on page 1--182) With the singulation release signal activate, only product in the discharge end of the conveyor (zone 1) will release. As the product clears the sensors, the adjacent upstream zones will advance into the discharge zone. Product will continue to discharge as long as the singulation release signal remains active. Slug Release (Figure 4 on page 1--182) With the slug release signal active, all accumulated product on the conveyor will release simultaneously. When the slug release signal is deactivated, the remaining product will resume normal accumulation. Predetermined slug lengths can be configured through the use of the slug respond switch on each controller. For more information on these and other features refer to the 22ZC installation instructions or visit our website at www.ab.com/sensors. System Overview for Powered Roller Driven Conveyor Systems Install one 22ZC in each zone of the conveyor and attach a suitable sensing and actuating device. Note that the infeed module (22ZC--343) must be installed at the beginning of your zone control system (zone 4 on Figure 1) and the master module (22ZC--413) at the discharge end of your system (zone 1 on Figure 1). Size, cut and install the flat media between each controller. Connect a suitable 24V DC power supply to any controller within the system. It is recommended to make this connection to the center controller for balanced power distribution. Note that the power for the powered roller and amplifier are not provided by the 22ZC, only the RUN signal. Wire the infeed and discharge zone external connection as required using the wiring diagram shown on Figure 1. Loading Product onto the Conveyor (Figure 2 on page 1--182) With power applied to the system, all zones will be OFF until either the infeed
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
sensor is blocked or the zone feed input is closed and maintained. As product passes the sensor mounted at the infeed zone, a gap will be formed equal to the zone length. This will ensure zero pressure throughout the whole system. Once the first product reaches the discharge zone (zone 1), it will stop and await release from the conveyor. If a low pressure accumulation is desired, a system wide OFF time delay can be configured to minimize product spacing on the conveyor. Release of Product Once the product has been transported and accumulated at the discharge end of the conveyor (zone 1) it may be release in one of two manners: Singulation Release (Figure 3 on page 1--182) With the singulation release signal activate, only product in the discharge end of the conveyor (zone 1) will release. As the product clears the sensors, the adjacent upstream zones will advance into the discharge zone. Product will continue to discharge as long as the singulation release signal remains active. Slug Release (Figure 4 on page 1--182) With the slug release signal active, all accumulated product on the conveyor will release simultaneously. When the slug release signal is deactivated, the remaining product will resume normal accumulation. Predetermined slug lengths can be configured through the use of the slug respond switch on each controller. For more information on these and other features refer to the 22ZC installation instructions or visit our website at www.ab.com/sensors.
1--181
Page 200
PHOTOSWITCHR Photoelectric Sensors
22ZC Zone Controller Figure 1. System Overview ZONE 4
ZONE 3
P4
P3
ZONE 2
ZONE 1
Direction of Product Flow P2
P1
™
™
™
™
Z4
Z3
Z2
Z1
Singulation Release Slug Release Zone State Signal
Zone Feed Zone State
Load
Load
+24V DC
Figure 2. Loading the Conveyor ZONE 4
ZONE 3
ZONE 2
ZONE 1
Direction of Product Flow P4
P3
P2
P1
™
™
™
™
Z4
Z3
Z2
Z1
Singulation Release Slug Release Zone State Signal
Zone Feed Zone State
Load
Load
+24V DC
Figure 3. Singulation Release of Accumulated Product ZONE 4
ZONE 3
ZONE 2
ZONE 1
Direction of Product Flow
P4
P3
P2
P1
™
™
™
™
Z4
Z3
Z2
Z1
Singulation Release Slug Release Zone State Signal
Zone Feed Zone State +24V DC
Load
Load
Figure 4. Slug Release of Accumulated Product ZONE 4
ZONE 3
ZONE 2
ZONE 1
Direction of Product Flow P4
P3
P2
P1
™
™
™
™
Z4
Z3
Z2
Z1
Zone Feed Zone State Load
+24V DC
Load
Singulation Release Slug Release Zone State Signal
™ Amplifier or Valve
1--182
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
Page 201
PHOTOSWITCHR Photoelectric Sensors
22ZC Zone Controller System Overview for Powered Roller Driven Conveyor Systems Install one 22ZC in each zone of the conveyor and attach a suitable sensing and actuating device. Size, cut and install the flat media between each controller. Using a 22ZC--PWR cordset, connect to a suitable 24V DC power supply to any controller within the system. It is recommended to make this connection to the center controller for maximum power distribution. A 4A supply will provide power for up to 50 zones. Note that the power for the powered roller and amplifier are not provided by the 22ZC, only the RUN signal. Wire the infeed and discharge zone external connections as required using the wiring diagram to the right. Note that the zone and slug release, and the zone feed push buttons should be normally open and maintained.
the conveyor (Zone 1), it may be released in one of two manners.
Loading Product onto the Conveyor With power applied to the system, all zones will be OFF until either the infeed sensor is blocked or the zone feed contact is closed and maintained. As product passes the sensor mounted at the infeed zone, a gap will be formed equal to the zone length. This will ensure zero pressure throughout the system. Once the first product reaches the discharge zone (1), it will stop and await release from the conveyor. If a low pressure accumulation is desired, a system-wide, 1 second OFF time delay can be configured to minimize product spacing on the conveyor.
Singulation Release With the zone release push button closed and maintained, only product in the discharge zone (1) will release. As the product clears the sensor, the adjacent upstream zones will advance into the discharge zone. Product will continue to discharge as long as the zone release push button remains closed.
Release of Product Once product has been transported and accumulated at the discharge end of
Slug Release With the slug release push button closed and maintained, all accumulated product on the conveyor will release simultaneously. When the slug release push button is released, the remaining product will resume normal accumulation. Predetermined slug lengths can be configured through the use of the SLUG RESPOND switch on each controller.
Approximate Dimensions [mm (in.)] 110.7 (4.36)
68.5 (2.70)
30 (1.18)
Description
Cat. No.
Description
Cat. No.
Description
22ZC- 413 (master)
Flat Media, 75 m spool
1485C- P1L75
Reflector, 3 in. diameter
Cat. No. 92- 39
Zone Controllers
22ZC- 223 (basic)
Power Supply, 24V DC/4 A
1606- XLP100E
Mounting Bracket, sensor
60- 2657
22ZC- 343 (infeed)
Power Tap
22ZC- PWR
Photoelectric Sensor
44RSP- 2JNE3- Z6
Power Tap, IDC
1485T- P1H4- R5
Refer to www.ab.com/sensors for more information.
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
1--183
Page 202
PHOTOSWITCHR Photoelectric Sensors
Series 9000 Intrinsically Safe Specifications Environmental
Description The Series 9000 transmitted beam photoelectric sensors are designed and approved as an intrinsically safe device under the FM and CSA entity concept. It may be installed into a Class I, II, III; Division 1 hazardous location when connected to an appropriate safety barrier. The sensor is also approved as non-incendive for installation into Class I; Division 2 hazardous locations without the need for a safety barrier. Typical applications
S Automotive S Petrochemical S Grain processing Information on the Series 897H intrinsic safety barriers may be found on page 12--2.
Features
S Intrinsically safe to North American
Certifications
UL Listed, FM Approved, and CE Marked for all applicable directives
Operating Environment
NEMA 3, 4X, 6P, 12, 13; IP67, 1200 psi washdown, IP69K
Operating Temperature [C (F)]
- 40…+65° (- 40…+150°)
Vibration
10…55 Hz, 1 mm amplitude, meets or exceeds IEC 60947- 5- 2
Shock
30 g with 1 ms pulse duration, meets or exceeds IEC 60947- 5- 2
Relative Humidity
5…95% max
Ambient Light Immunity
Incandescent light 5000 lux
Optical Sensing Modes
Transmitted Beam
Light Source
Infrared LED (880 nm)
LED Indicators
Red LED for output indication
Adjustments
Sensitivity potentiometer
Electrical Voltage
13…30V DC
Current Consumption
25 mA max
Sensor Protection
Overload, short circuit, reverse polarity, false pulse
Outputs Response Time
10 ms max
Output Type
PNP and NPN
Output Mode
Light operate and dark operate selectable
Output Current
8.5 mA for PNP, 15 mA for NPN
Output Leakage Current
10 μA max standards Transmitted beam sensing mode
Mechanical Housing Material
ValoxR intrinsic safety barriers 30 mm harsh duty package
Lens Material
Acrylic
Connection Types
2 m cable, 4-pin DC micro (M12) QD, 4-pin DC mini QD
Supplied Accessories
129- 130 mounting kit
Optional Accessories
Series 897H intrinsic safety barriers, cordsets, mounting brackets
S S Compatible with Series 897H S S Fast response time S Variety of connection types
Selection Guide for Intrinsic Safety Barriers The 42GRx--95x0 is approved as an intrinsically safe apparatus under the entity concept by FM and CSA. Therefore, any safety barrier which meets both the stated operational and safety requirements (see Table 1) of the
1--184 sensor may be used. Note that the Table 1 sensor is also approved as Entity Parameters non--incendive (FM) for installation into Sensor Class I; Division 2 hazardous locations without the need for a safety barrier. Vmax 31.5V
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
Barrier ≥
Vt
Imax
150 mA
≥
It
Pmax
0.95 W
≥
Pt
Ci + Cleads
0 uF
≤
Ca
Li + Lleads
0 mH
≤
La
Page 203
PHOTOSWITCHR Photoelectric Sensors
Series 9000 Intrinsically Safe User Interface Label
Color
Output
Green
Margin/SCP
State
Red
Power
Yellow
Status
OFF
Sensor output de-activated
ON
Sensor output activated
OFF
Margin <2.5
ON
Margin>2.5
Flashing
Output SCP active
OFF
Sensor not powered
ON
Sensor powered
Wiring Diagrams 42GRL Light Source Class I, II, III; Division 1 or 2; Group A, B, C, D, E, F, G Hazardous Location DIN Rail
T
1 3
Nonhazardous Location Power Supply 24…26V DC + --
3 1 897H- S120 4 2 Intrinsic Safety Barrier G G
I.S. Ground Conductor
42GRR Receiver with PNP Output DIN Rail
T
1 4 3
3 1 897H- S214 4 2 Intrinsic Safety Barrier G G
RLoad
Power Supply 24…26V DC + --
Discrete Input Module I.S. Ground Conductor
42GRR Receiver with NPN Output DIN Rail
T
1 2 3
3 1 897H- S150 4 2 Intrinsic Safety Barrier G G 3 1 897H- S150 4 2 G Intrinsic Safety Barrier G
RLoad
Power Supply 24…26V DC + --
Discrete Input Module
I.S. Ground Conductor
IMPORTANT
See Control Drawing #75002--200.
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
1--185
Page 204
PHOTOSWITCHR Photoelectric Sensors
Series 9000 Intrinsically Safe Approximate Dimensions [mm (in.)] Cable Version
55.62 (2.190)
Transmitted Beam 10000
15.24 (0.600)
31.75 (1.250)
47.75 (1.880)
1000 Operating Margin
74.93 (2.950) Ref 69.85 (2.750)
4000
20.96 (0.825)
7.62 (0.300) 103.63 (4.080) 27.05 Max. Travel (1.065) 42.41 (1.670)
5.21 (0.205) X 8.13 (0.320) Slot, 2 PLCS
M30 X 1.5 15.87 External (0.625) Thread 5.46 1/2 in. NPSM (0.215) Internal Thread
Cable Length 2 m (6.5 ft) 6.5 (0.255/0.245) Dia.
Typical Response Curve
16.76 (0.660) 32.66 (1.286)
41.91 (1.650)
40.00 (1.575)
400 100 40 10
24.69 (0.970)
4
30.35 (1.195)
1 0.3 (1)
1.8 (5)
3 (10)
15 (50)
30 (100)
150 (500)
Operating Distance [m (ft)]
Product Selection Sensing Mode
Operating Voltage Supply Current
Light Sources
14…30V DC 16 mA
Sensing Distance 25.4 mm…106 m (2 in…350 ft)
Output Energized, Output Type Capacity Response Time, Connection Type
Cat. No.
2 m 300V cable
42GRL- 9540
4-pin micro
42GRL- 9540- QD
4-pin mini
42GRL- 9540- QD1
2 m 300V cable
42GRR- 9500
4-pin micro
42GRR- 9500- QD
4-pin mini
42GRR- 9500- QD1
Receivers
Object to be Sensed
13…30V DC 25 mA
25.4 mm…106 m (2 in…350 ft)
Light/Dark Operate
NPN/15 mA PNP/8.5 mA 10 ms max.
Transmitted Beam Field of View: 1.5_ Receiver Emitter LED: Infrared 880 nm
Cordsets and Accessories Description
Cat. No.
1.8 m (6 ft) 4-pin, Mini QD Cordset
889N- F4AF- 6F ™
2 m (6.5 ft) 4-pin, DC Micro QD Blue Cordset
889D- F4LC- 2 š
Mounting Bracket
60- 2439
™ Intrinsically Safe wiring labels 897H--L1 or 897H--L2 must be applied every 7.6 m (25 ft).
š Blue cable does not require labels to denote intrinsically safe wiring.
1--186
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
Page 205
PHOTOSWITCHR Photoelectric Sensors
Series 5000 Intrinsically Safe Specifications Environmental Certifications
UL Listed, FM Approved, and CE Marked for all applicable directives
Operating Environment
NEMA 3, 4, 12, 13; IP66
Operating Temperature [C (F)]
- 40…+65° (- 40…+150°)
Vibration
10…55 Hz, 1 mm amplitude, meets or exceeds IEC 60947- 5- 2
Shock
30 g with 1 ms pulse duration, meets or exceeds IEC 60947- 5- 2
Relative Humidity
90% max
Ambient Light Immunity
Incandescent light 5000 lux
Optical
Description
Sensing Modes
Retroreflective, diffuse, polarized retroreflective, fiber optic
The Series 5000 intrinsically safe sensors are designed for the installation in hazardous locations. They can be used in Class I, II, III; Division 1, 2; groups A, B, C, D, E, F, and G locations with intrinsic Safety Zener Diode Barriers. They can also be used in Class I, II, II; Division 2 only without intrinsic safety zener diode barriers.
Sensing Range
See Product Selection table on page 1- 189
Field of View
See Product Selection table on page 1- 189
Light Source
Infrared LED (880 nm)
LED Indicators
Red LED for output indication
Adjustments
Sensitivity potentiometer
Features
S Intrinsically Safe to North American standards
S Nonincendive for Division 2 hazardous (classified) locations
S Modular package for increased flexibility
S Wide variety of sensing modes
Electrical Voltage
24V DC with suitable intrinsically safe barrier
Current Consumption
30 mA max
Sensor Protection
False pulse
Outputs Response Time
1 ms
Output Type
PNP and NPN
Output Mode
Light and dark operate selectable
Output Current
20 mA @ 28V DC
Output Leakage Current
1 μA
Mechanical
S Selectable light/dark operation
Housing Material
Valoxr
S Both NPN and PNP outputs S Screw terminal connections
Lens Material
Acrylic (glass on polarized lens)
Connection Types
2 m (6.5 ft) cable, screw terminal
Supplied Accessories
None
Optional Accessories
See mounting brackets, reflectors, and cordsets on page 1- 190
User Interface Label
Color
Output
Red
State
Status
OFF
Sensor output de-activated
ON
Sensor output activated
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
1--187
Page 206
PHOTOSWITCHR Photoelectric Sensors
Series 5000 Intrinsically Safe Wiring Diagrams Photohead and Terminal Base with PNP Output Hazardous Location
Nonhazardous Location Power Supply 24…26V DC + --
DIN Rail + 3 2 --
3 1 897H- S120 4 Intrinsic Safety Barrier 2 G G 3 1 897H- S140 4 Intrinsic Safety Barrier 2 G G
RLoad
Discrete Input Module
I.S. Ground Conductor
Photohead and Terminal Base with NPN Output - Groups C--G only
Power Supply 24…26V DC + --
DIN Rail + 1 --
3 1 897H- S150 4 Intrinsic Safety Barrier 2 G G 3 1 897H- S150 4 Intrinsic Safety Barrier 2 G G
RLoad
Discrete Input Module
I.S. Ground Conductor
IMPORTANT
See Control Drawing #133--451.
Approximate Dimensions (Applies to all versions) [mm (in.)] Terminal Style Power Base
To Remove Photohead 36.5 (1.44)
8.7 Min. (1.03)
24.2 (0.95)
Top View QuickDisconnect Screw
11.9 (0.47) 15.4 (0.45)
2.7. (0.11)
LED Indicator
71.0 (2.80) 139.5 (5.52) 106.5 (4.25)
65.8 (2.59)
Bottom View 13.8 (0.55)
1/2--14 NPSM
38.3 (1.50)
27.7 (1.09) 55.5 (2.19)
33.3 (1.31)
Note: Hardware included with sensor: two (2) nickel-plated 10--32 mounting screws.
1--188
19.4 (0.77) 36.5 (1.44)
10--32 UNF 2 Holes
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
8.3 (0.33)
55.5 (2.19)
Page 207
PHOTOSWITCHR Photoelectric Sensors
Series 5000 Intrinsically Safe Typical Response Curve Polarized Retroreflective
40
16 (0.625) Reflector
4
32 (1.25) Reflector
2 1 25.4 (1.0)
609.6 (24)
152 (6.0)
100 76 (3) Reflector
20 10 8 4 3 32 (1.25) Reflector
2 1
3m 6m 15m (10 ft) (20 ft)(50 ft)
2.54 (0.1)
Operating Distance [mm (in.)]
Large Aperture Fiber Optic 200 40 20
16 (0.625)
32 (1.25)
25.4 (1.0)
2 1
1000
10
152 609.6 3m 15m (6.0) (24) (10 ft) (50 ft)
Operating Distance [mm (in.)] Fibers #43GR- FAS25SL through #43GR- BAA72ML See Fiber Optic section in this catalog for additional information.
1 12.7 (0.5)
152 609.6 3m 15m (6.0) (24) (10 ft) (50 ft) 6.1m (20 ft) Operating Distance [mm (in.)]
Wide Angle Lens
100
1
Long Range
4
25.4 (1.0)
1000
4
2.54 (0.1)
152 609.6 3m 15m (6.0) (24) (10 ft) (50 ft)
Fixed Focus Lens
76 (3) Reflector
White Paper
25.4 (1.0)
Short Range
20 10
Operating Distance [mm (in.)]
Operating Margin
Operating Margin
1000 400
40
Operating Margin
20 10
Standard Diffuse
40
76 (3) Reflector Operating Margin
Operating Margin
200 100
Operating Margin
Retroreflective
25.4 (1.0)
127 (5.0)
100
10
1 12.7 (0.5)
Operating Distance [mm (in.)]
25.4 (1.0)
254 (10)
508 (20)
Operating Distance [mm (in.)]
Product Selection Photohead Sensing Mode
Object to be Sensed
Output Energized
Output Type Capacity
50.8 mm…10 m (2 in…33 ft) with 76 mm (3 in.) Reflector
Light/Dark Selectable
50.8 mm…6 m (2 in…20 ft) with 76 mm (3 in.) Reflector
Light/Dark Selectable
Sensing Distance
Response Time
Cat. No.
NPN and PNP 20 mA at 29.5V DC
1 ms
42DRU- 5500
NPN and PNP 20 mA at 29.5V DC
1 ms
42DRU- 5700
Retroreflective Field of View: 2.5_ Emitter LED: Infrared 880 nm
Object to be Sensed
Polarized Retroreflective Field of View: 2.5_ Emitter LED: Visible 660 nm
Refer to page 1--190 for cordsets and accessories.
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.
1--189
Page 208
PHOTOSWITCHR Photoelectric Sensors
Series 5000 Intrinsically Safe Product Selection (continued) Photohead Sensing Mode
Output Energized
Output Type Capacity
50.8 mm (2 in.)…Short Range: 0.4 m (16 in.) Long Range: 2.1 m (7 ft) with White Paper
Light/Dark Selectable, Light/Dark Selectable
Sensing Distance
Object to be Sensed
Response Time
Cat. No.
NPN and PNP 20 mA at 29.5V DC
1 ms
42DRP- 5500
NPN & PNP 20 mA at 29.5V DC
1 ms
42DRA- 5500 ™
Standard Diffuse Field of View: 3_ Emitter LED: Infrared 880 nm
Object to be Sensed
Large Aperture Fiber Optic Field of View: Depends on the glass fiber optics and lens type Emitter LED: Infrared 880 nm ™ Lens assembly required, see below.
Power Base Style
Operating Voltage
Supply Current
Cat. No.
Terminal
13…29.5V DC
26 mA max at 13V DC 30 mA max at 29.5V DC
42DTB- 5500
Cordsets and Accessories
Lens Assembly Lens Type
Cat. No.
Description
Page No.
Fiber Optic
61- 5550
Mounting Assemblies
1- 293
Fixed Focus
61- 5551
Intrinsic Safety Barriers
12- 2
61- 5611
76 mm (3 in.) Diameter Reflector
92- 39
32 mm (1.25 in.) Diameter Reflector
92- 47
Wide Angle
1--190
Visit our website: www.ab.com/catalogs. Preferred availability cat. nos. are printed in bold.