For the Allen-Bradley 2755-LS7

Page 31

Chapter

4

Installing Your Hardware This chapter provides the information needed to install the readers and interface boxes. Items include: • installing the system hardware • connecting system hardware together when using an interface box • connecting system hardware together when using an auxiliary monitor • connecting system hardware together when using a daisy-chain configuration • connecting system hardware together when not using an interface box

Publication 2755-6.9

Page 32

4–2

Installing Your Hardware

Installing the System Hardware

Refer to the following steps to install your system hardware properly. 1. Make sure your scanner system is planned out properly. Refer to chapter 3 for information regarding planning your scanner system. 2. Mount the reader (Catalog Nos. 2755-LS7-SA, 2755-LS7-SB, 2755-LS7-RA, 2755-LS7-RB, 2755-LS7-SBV, or 2755-LS7-RBV) to the mounting plate (Catalog No. 2755-LS7-N) or directly to your mounting surface. The dimensions of the reader are shown on the next page. The dimensions of the mounting plate are shown below. The maximum distance from the reader to another device is 3 ft. (0.91 m). Use # 6 screws with maximum penetration of 0.15 in. (3.81 mm). If you are not using the mounting plate, go to step #4. Reader

Mounting Plate

Note: The drawing below is not to scale. 2.60 in. (6.62 cm)

2.08 in. (5.30 cm) 2.58 in. (6.57 cm) 1.26 in. (3.21 cm)

2.39 in. (6.08 cm) 3.85 in. (9.77 cm) 4.35 in. (11.04 cm)

Publication 2755-6.9

Page 33

Installing Your Hardware

4–3

The dimensions of the readers are shown below. Note: The drawing below is not to scale. Bottom View

2.59 in. (6.58 cm)

1.36 in. (3.49 cm)

2.5 in. (6.35 cm)

3.47 in. (8.81 cm)

Side View (Catalog Nos. 2755-LS7-SA, -SB, -RA, and -RB)

2.25 in. (5.72 cm)

1.32 in. (3.35 cm)

2.59 in. (6.58 cm)

Side View (Catalog Nos. 2755-LS7-SBV and -RBV)

2.25 in. (5.72 cm)

0.74 in. (1.88 cm) 1.32 in. (3.35 cm)

0.65 in. (1.65 cm)

2.59 in. (6.58 cm)

Publication 2755-6.9

Page 34

4–4

Installing Your Hardware

3. Mount the plate to your mounting surface. You can mount the plate to the top, bottom, or side of your mounting surface. Use # 6 screws. Make sure placement of the mounting plate will allow you to connect the reader to the interface box (Catalog Nos. 2755-LS7-IB1 and 2755-LS7-IB2) or other network device. The maximum distance from the interface box to the reader is 3 ft. (0.91 m). Skip steps #4 and #5 if you are not using an interface box. Reader

Mounting Surface

4. Mount the interface box to your mounting surface. Use # 6 screws with maximum penetration of 0.25 in. (6.35 mm). Interface Box

Mounting Surface

5. Place the power supply within 6 ft. (1.83 m) of the interface box.

Publication 2755-6.9

Page 35

Installing Your Hardware

Connecting System Hardware Together When Using an Interface Box

4–5

Follow the steps starting below to connect your system hardware together when using an interface box. Refer to appendix B for cable pinouts. 1. Plug the reader into the interface box. Interface Box

To Scanner Port

Reader

2. Plug any sinking package detect or relay options to the trigger connector port on the interface box. For example, use a Switchcraft connector (No. 12BL6M) or equivalent to connect to the trigger connector port. Contact Switchcraft at (312) 631–1234 for connector availability and pricing. Interface Box

To Trigger Connector

Package Detector

Publication 2755-6.9

Page 36

4–6

Installing Your Hardware

To wire the Switchcraft connector, refer to the following table. Contact your local Allen-Bradley sales office or distributor for more information regarding PHOTOSWITCH photoelectric sensors. Switchcraft Connector Pin

Function of Connection

PHOTOSWITCH Wire Color

One

Trigger from switch

Black (Output)

Four

+12V dc from interface box

Brown

Five

Ground

Blue

3. Plug host device or configuration terminal into the RS-232 or RS-485/422 port on the interface box. If you are using the RS-485/422 port, press the mode switch on the interface box to access the correct communication protocol. Interface Box

To RS-232 Port

To Host Device

Publication 2755-6.9

To RS-485/422 Port

Page 37

Installing Your Hardware

4–7

4. Plug the power supply into the interface box. Interface Box

To Power Port

Power Supply

5. Connect the power supply cable to the power supply and to the power receptacle supplying 100-240V ac. To Power Receptacle

To Power Supply Grounding Pin

6. Turn on the interface box. If you are using a configuration terminal, you can now perform the configuration sequence. Refer to chapter 5 for the reader configuration sequence information. After performing the configuration sequence: 1. Turn off power to the reader. 2. Unplug the configuration terminal from the interface box. 3. Connect the interface box to the host device. 4. Turn on the interface box. Interface Box

Power Switch

Publication 2755-6.9

Page 38

4–8

Installing Your Hardware

Connecting System Hardware Together When Using an Interface Box with an Auxiliary Monitor

Follow the steps starting below to connect your system hardware together when using an auxiliary monitor. You can only use Series B or higher of the reader when using an auxiliary monitor. Refer to appendix B and page 6–11 for cable pinouts. 1. Plug the reader into the interface box. Interface Box

To Scanner Port

Reader

2. Plug any sinking package detect or relay options into the trigger connector port on the interface box. For example, use a Switchcraft connector (No. 12BL6M) or equivalent to connect to the trigger connector port. Contact Switchcraft at (312) 631–1234 for connector availability and pricing. Interface Box

To Trigger Connector

Package Detector

Publication 2755-6.9

Page 39

Installing Your Hardware

4–9

To wire the Switchcraft connector, refer to the following table. Contact your local Allen-Bradley sales office or distributor for more information regarding PHOTOSWITCH photoelectric sensors. Switchcraft Connector Pin

Function of Connection

PHOTOSWITCH Wire Color

One

Trigger from switch

Black (Output)

Four

+12V dc from interface box

Brown

Five

Ground

Blue

3. Construct a cable that has three 25-pin connectors and will allow you to connect the host device or configuration terminal, interface box, and auxiliary port together. Refer to appendix B and page 6–11 for information regarding cable pinouts. 4. Connect the interface box to host device or configuration terminal and auxiliary port. Interface Box

To RS-232 Port

To Host Device To Auxiliary Monitor

Publication 2755-6.9

Page 40

4–10

Installing Your Hardware

5. Plug the power supply into the interface box. Interface Box

To Power Port

Power Supply

6. Connect the power supply cable to the power supply and to the power receptacle supplying 100-240V ac. To Power Receptacle

To Power Supply Grounding Pin

7. Turn on the interface box. If you are using a configuration terminal, you can now perform the configuration sequence. Refer to chapter 5 for the reader configuration sequence information. After performing the configuration sequence: 1. Turn off power to the reader. 2. Unplug the configuration terminal from the interface box. 3. Connect the interface box to the host device. 4. Turn on the interface box. Interface Box

Power Switch

Publication 2755-6.9

Page 41

Installing Your Hardware

Connecting System Hardware Together When Using an Interface Box in a Daisy-Chain Configuration

4–11

Follow the steps starting below to connect your system hardware together when using an interface box. You can only use Series B or higher of the reader when using the daisy-chain configuration except for the last reader used in the chain. Refer to appendix B and page 6–9 for cable pinouts. 1. Plug each reader into a separate interface box. Interface Box

To Scanner Port

Reader

2. Plug any sinking package detect or relay options to the trigger connector port on each of the interface boxes. For example, use a Switchcraft connector (No. 12BL6M) or equivalent to connect to the trigger connector port. Contact Switchcraft at (312) 631–1234 for connector availability and pricing. Interface Box

To Trigger Connector

Package Detector

Publication 2755-6.9

Page 42

4–12

Installing Your Hardware

To wire the Switchcraft connector, refer to the following table. Contact your local Allen-Bradley sales office or distributor for more information regarding PHOTOSWITCH photoelectric sensors. Switchcraft Connector Pin

Function of Connection

PHOTOSWITCH Wire Color

One

Trigger from switch

Black (Output)

Four

+12V dc from interface box

Brown

Five

Ground

Blue

3. Construct a cable that has 25-pin connectors and will allow you to connect the host device or configuration terminal and interface boxes together. Refer to appendix B and page 6–9 for information regarding cable pinouts. 4. Connect the master interface box to the host device or configuration terminal and slave interface box. (The master interface box is connected to the master reader and the slave interface box is connected to the slave reader.) Master Interface Box

To RS-232 Port

To Host Device

Publication 2755-6.9

Slave Interface Box

To RS-232 Port

Page 43

Installing Your Hardware

4–13

5. Plug a power supply into each interface box. Interface Box

To Power Port

Power Supply

6. Connect a power supply cable to each power supply and to the power receptacle supplying 100-240V ac. To Power Receptacle

To Power Supply Grounding Pin

7. Turn on each interface box. If you are using a configuration terminal, you can now perform the configuration sequence for the master reader. Refer to chapter 5 for the reader configuration sequence information. After performing the configuration sequence on the master reader: 1. Turn off power to the master reader. 2. Unplug the configuration terminal from the master interface box. 3. Connect the master interface box to the host device. 4. Turn on the master interface box. Interface Box

Power Switch

5. Turn off power to the slave reader.

Publication 2755-6.9

Page 44

4–14

Installing Your Hardware

6. Disconnect the slave interface box from the master interface box. 7. Connect the configuration terminal to the slave interface box. 8. Turn on the slave interface box. 9. Configure the slave reader. Refer to chapter 5 for the reader configuration sequence information. 10. Turn off power to the slave reader. 11. Unplug the configuration terminal from the slave interface box. 12. Connect the slave interface box to the master interface box. 13. Turn on the slave interface box.

Publication 2755-6.9

Page 45

Installing Your Hardware

Connecting System Hardware Together When Not Using an Interface Box

4–15

Follow the steps below to connect your system hardware together when not using an interface box. 1. Determine which pins on the reader cable connector are needed. Refer to appendix B for a listing of the connector pins of the reader cable. 2. Construct a mating cable that attaches to the reader cable on one end and to the other devices on the other end, used in the application. These devices include: • RS-232 host device • 5 V, 500 mA power supply • package detect sensor • new master input • default configuration input • devices connected to the reader which uses the TTL relay outputs 3. Plug the reader into the mating cable. 4. Plug the mating cable into the host device, power supply, and other devices as required by the application.

Publication 2755-6.9