Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 18

AtomScan+ Bar Code Readers User Manual (Cat. Nos. 2755-LS7-SA, 2755-LS7-SB, 2755-LS7-RA, 2755-LS7-RB, 2755-LS7-SBV, and 2755-LS7-RBV), pages 7 to 15

Pages 7 to 15 of 141: Preface; 1 - Introduction to AtomScan Bar Code Readers

The original document is the PDF (914 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-LS7

Page 7

Preface Chapter Objectives

Read this chapter to familiarize yourself with the rest of the manual. You will learn about: • contents of this manual • conventions used in this manual • intended audience • related publications • technical support services

Contents of this Manual

The following table describes the contents of this manual. Chapter

Title

Contents

Preface

Describes the purpose, background, and scope of this manual. Also specifies the audience for whom this manual is intended.

1

Introduction to AtomScan+ Bar Code Readers

Provides an introduction for the use of the AtomScan+ Bar Code Readers.

2

Hardware Features

Provides an overview of the readers and interface boxes. Includes a description of accessory items.

3

Designing Your Scanner System

Provides information needed to design and implement a scanner system.

4

Installing Your Hardware

Describes how to connect your scanner system hardware.

5

Configuring Your Reader

Describes configuration options for the reader.

6

Hardware Operation

Describes how to operate your system hardware.

7

Maintenance and Troubleshooting

Describes how to maintain and troubleshoot your scanner system hardware.

Appendix A

Specifications

Provides physical, electrical, environmental, and functional specifications for the readers and interface box.

Appendix B

Cable Pinouts

Lists the cable pinouts for reader cable.

Appendix C

ASCII Table

Lists ASCII conversion chart.

Appendix D

Multidrop Communications

Describes the rules for setting up a concentrator or controller to communicate with an AtomScan+ Bar Code Reader.

Appendix E

Application Examples

Illustrates various applications.

Appendix F

European Union Directives

Provides requirements for readers when used within the European Union.

Glossary

Provides terms found within this document.

Publication 2755-6.9

Page 8

P–2

Preface

Conventions Used in this Manual

The following conventions are used throughout this manual. • Bulleted lists such as this one provide information, not procedural steps. • Numbered lists provide sequential steps. • Italic type is used for emphasis. • Text within square brackets [in this font] represent the keys you press.

Intended Audience

No special knowledge is required to understand this document or use the AtomScan+ Bar Code Readers (Catalog Nos. 2755-LS7-SA, 2755-LS7-SB, 2755-LS7-RA, 2755-LS7-RB, 2755-LS7-SBV, and 2755-LS7-RBV).

! Related Publications

ATTENTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.

The following table lists the other publication related to the AtomScan+ Bar Code Readers. Publication Number 2755-921

Technical Support Services

Title Bar Code Basics

If you have any questions about the AtomScan+ Bar Code Reader, please consult this manual first. If you can’t find the answer, contact Rockwell Automation International Support: Rockwell International Technical Support 6680 Beta Drive Mayfield Village, Ohio 36849 Inside USA and Canada, call 1–800–289–2279. Outside USA and Canada, contact your Allen-Bradley office or call USA (216) 646–6800.

Publication 2755-6.9

Page 9

Chapter

1

Introduction to AtomScan+ Bar Code Readers This chapter can help you to get started using the AtomScan+ Bar Code Readers. We base the procedures here on the assumption that you have an understanding of bar code scanners and control equipment. Because it is an introduction, this chapter does not contain detailed explanations about the procedures listed. It does, however, reference other chapters in this book where you can get more information. If you have any questions or are unfamiliar with the terms used or concepts presented in the procedural steps, always read the referenced chapters and other recommended documentation before trying to apply the information. This chapter tells you: • what tools and equipment you need • procedures for getting your scanner system up and running

Required Tools and Equipment

Have the following tools and equipment ready: • screwdriver • drill • tape measure • personal computer with terminal program and an RS-232 cable

Publication 2755-6.9

Page 10

1–2

Introduction to AtomScan+ Bar Code Readers

Procedures 1.

Check the contents of shipping boxes.

Reference

Unpack the shipping boxes making sure that the contents include:

•

AtomScan+ Bar Code Readers (Catalog Nos. 2755-LS7-SA, 2755-LS7-SB, 2755-LS7-RA, 2755-LS7-RB, 2755-LS7-SBV, or 2755-LS7-RBV)

• • •

AtomScan + Bar Code Readers User Manual on disk (Publication No. 2755-6.9-DISK)

•

Interface Boxes for the AtomScan + Bar Code Readers Installation Instructions [Catalog No. 40062-366-01 (A)]

• •

Mounting Plate for the AtomScan+ Bar Code Readers (Catalog No. 2755-LS7-N1)

• •

AtomScan + Bar Code Readers Installation Instructions (Publication No. 2755-5.13) Interface Boxes for the AtomScan+ Bar Code Readers (Catalog Nos. 2755-LS7-IB1 or 2755-LS7-IB2) –

Mounting Plate for the AtomScan + Bar Code Readers Installation Instructions [Catalog No. 40062-367-01 (A)] Power Supply for the AtomScan+ Bar Code Readers (Catalog No. 2755-LS7-PW1) Power Supply for the AtomScan + Bar Code Readers Installation Instructions [Catalog No. 40062-368-01 (A)]

If the contents are incomplete, call your local Allen-Bradley representative for assistance.

2.

Design the scanner system.

Each application must be evaluated carefully. Successful bar code scanning begins with quality bar code symbols and the correct number, type, and location of readers, decoders, and package sensors. Refer to the following when designing your scanner system.

• • • •

Before setting up the system, calculate the expected number of scans per symbol. Make sure the reader can view the number of scans it needs. If necessary, adjust the symbol speed and/or the distance between bar-coded packages. Position the reader at a distance from the symbol that is within the range specified. A read rate test should be made to verify the range, and also to ensure optimum scanning and decoding. Avoid aiming the reader perpendicular to the symbol, to avoid directly reflected laser light. If a package sensor is used, position it so it can sense the package before the symbol reaches the scan area.

Note: Make sure that the scan beam does not hit the sensor’s reflector; the resulting glare can blind the reader temporarily.

Publication 2755-6.9

Reference

Chapter 3 (Designing Your Scanner System)

Page 11

Introduction to AtomScan+ Bar Code Readers

3.

Install the reader.

1–3

Reference

Mount the reader (Catalog Nos. 2755-LS7-SA, 2755-LS7-SB, 2755-LS7-RA, 2755-LS7-RB, 2755-LS7-SBV, or 2755-LS7-RBV) to the mounting plate (Catalog No. 2755-LS7-N) or directly to your mounting surface. [The maximum distance from the reader to another device is 3 ft. (0.91 m)]. Use # 6 screws with maximum penetration of 0.15 in. (3.81 mm). If you are not using the mounting plate, go to step #4.

Chapter 4 (Installing Your Hardware)

Reader

Mounting Plate

Mount the plate to your mounting surface. You can mount the plate to the top, bottom, or side of your mounting surface. Use # 6 screws. Make sure placement of the mounting plate will allow you to connect the reader to the interface box (Catalog Nos. 2755-LS7-IB1 or 2755-LS7-IB2) or other network device. The maximum distance from the interface box to the reader is 3 ft. (0.91 m). Skip steps #4 and #5 if you are not using an interface box. Reader

Mounting Surface

Publication 2755-6.9

Page 12

1–4

Introduction to AtomScan+ Bar Code Readers

4.

Install the interface box.

Reference

Mount the interface box to your mounting surface. Use # 6 screws with maximum penetration of 0.25 in. (6.35 mm).

Chapter 4 (Installing Your Hardware)

Interface Box

Mounting Surface

5.

Install the power supply.

Reference

Place the power supply within 6 ft. (1.83 m) of the interface box.

6.

Chapter 4 (Installing Your Hardware)

Connect the hardware components together.

Reference

Chapter 4 (Installing Your Hardware)

If you are using an interface box, connect the reader, power supply, package detect, and host or configuration terminal to the interface box. If you are not using an interface box, connect the reader to the host device, power supply, and any input or output device via a custom cable. Front View of Interface Box

Scanner Port

Rear View of Interface Box

Power Port

RS-232 Port

Trigger Connector

For information regarding installing the reader for use with an auxiliary monitor or in a daisy-chain configuration, refer to chapter 4 of this manual.

Publication 2755-6.9

RS-485/422 Port

Chapter 4 (Installing Your Hardware)

Page 13

Introduction to AtomScan+ Bar Code Readers

7.

Apply power to the scanner system.

1–5

Reference

After all of your hardware components are installed, apply power to your scanner system. Push the power button in on the interface box.

Chapter 4 (Installing Your Hardware)

Front View of the Interface Box

Power Switch

8.

Check the reader defaults.

Check the following configuration parameters on your host device. (Make sure you have a Windowst terminal utility software on your personal computer.) Make sure the defaults match the settings listed below. If the defaults do not match, communication between the reader and host device will not occur.

• • • •

Reference

Chapter 5 (Configuring Your Reader)

baud rate = 9600 parity = even stop bits = one data bits = 7

Read a test bar code to verify that the default settings are correct (i.e., the reader is communicating with the configuration device).

Publication 2755-6.9

Page 14

1–6

Introduction to AtomScan+ Bar Code Readers

9.

Change the appropriate configuration settings.

Reference

Press [<D>] to access the Main menu. The Main menu appears:

Chapter 5 (Configuring Your Reader)

From the Main menu you are able to access the configuration settings and change the settings needed for your application. Use the designated keys to scroll to and select the parameter you wish to change. Press space bar key (SP) or [N] to scroll ahead, [B] to scroll back, carriage return key (CR) to select, and [M] to return to the previous higher level menu. To return to the Main menu at any time, press [ESC] and [M]. If you need to set the reader to the default settings, refer to chapter 6.

10.

Turn off power to the interface box.

Reference

Push the power button in on the interface box.

Chapter 4 (Installing Your Hardware)

Front View of the Interface Box

Power Switch

Publication 2755-6.9

Page 15

Introduction to AtomScan+ Bar Code Readers

11.

1–7

Unplug the configuration terminal from the interface box.

Reference

Unplug the configuration terminal from the RS-232 or RS-485/422 port on the interface box.

Chapter 4 (Installing Your Hardware)

Rear View of the Interface Box

RS-232 Port

12.

RS-485/422 Port

Plug in the host device to the interface box.

Reference

Plug in the host device to the RS-232 or RS-485/422 port on the interface box.

Chapter 4 (Installing Your Hardware)

Rear View of the Interface Box

RS-232 Port

13.

RS-485/422 Port

Reapply power to the interface box.

Reference

Push the power button in on the interface box.

Chapter 4 (Installing Your Hardware)

Front View of the Interface Box

Power Switch

Publication 2755-6.9