Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 18 of 18

AtomScan+ Bar Code Readers User Manual (Cat. Nos. 2755-LS7-SA, 2755-LS7-SB, 2755-LS7-RA, 2755-LS7-RB, 2755-LS7-SBV, and 2755-LS7-RBV), pages 134 to 141

Pages 134 to 141 of 141: F - European Union Directives; Glossary; Back Cover

The original document is the PDF (914 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-LS7

Page 134

Appendix

F

European Union Directives This appendix provides information regarding: • compliance to European Union Directives • declaration of conformity

Compliance to European Union Directives

If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. This product is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) and the following standards, in whole or in part, documented in a technical construction file: • EN 50081-2 EMC – Generic Emission Standard, Part 2 – Industrial Environment • EN 50082-2 EMC – Generic Immunity Standard, Part 2 – Industrial Environment This product is intended for use in an industrial environment.

Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131–2 Programmable Controllers, Part 2 – Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: • Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication 1770-4.1 • Guidelines for Handling Lithium Batteries, publication AG-5.4 • Automation Systems Catalog, publication B111

Publication 2755-6.9

Page 135

F–2

European Union Directives

Declaration of Conformity

Below is a copy of the Declaration of Conformity for the AtomScan+ Bar Code Readers (Catalog Nos. 2755-LS7-SA, 2755-LS7-SB, 2755-LS7-RA, 2755-LS7-RB, 2755-LS7-SBV, and 2755-LS7-RBV) and power supply (Catalog No. 2755-LS7-PW1).

43500-256-01

Publication 2755-6.9

Page 136

Glossary Autodiscriminate – The ability to decode several different bar code symbologies without changing configuration. AWG – Abbreviation for American Wire Gauge. This is a standard measuring system for wire sizes, listed from 0 (biggest) to 40 (smallest). A 26 AWG is equivalent to 0.0159 in. (0.405 mm) in diameter. Bar Code – Data that has been encoded into an array of parallel bars and spaces of varying widths. Bar Code Density – Number of characters per inch or other unit of measure. Baud Rate – The term used to describe the number of discrete signal events per second. In RS-232 and RS-422/485 systems, baud rate is the same as bits per second (bps). Code 39 – An alphanumeric bar code with a character set containing a start/stop character, 10 numbers, 26 letters, 6 symbols, and a space. This code is discrete, variable length, and self-checking. Configuration – The method used to change factory default settings for operational features to match a specific application. Configuration can be done through menu selection or with serial commands. Connector – Physical device (plug or socket) on unit or cable to provide in/out connectivity for various circuits and pins. Counter – Memory space provided to keep track of read cycle events. Decode Rate – The number of good reads per second decoded by the reader. Depth of Field – The distance between the minimum and maximum range in which a reader can read bar code labels. EPROM – Erasable, programmable, read only memory. End of Read Cycle – The time at which the reader stops expecting label information to decode. This can be caused by a timeout, a trigger event, or a good read. Focal Length – The distance measured from the reader to the center of the depth of field, or focal point.

Publication 2755-6.9

Page 137

G–2

Glossary

Good Read – The event that occurs when a label’s data is accurately scanned and decoded. Intercharacter Gap – The extra space between the last element of one character and the first element of the adjacent character of a specific bar code symbol. Label Height – Regardless of orientation, the measurement taken along the length of a label’s individual bars. Label Length – Regardless of orientation, the measurement taken across the label’s bars from one end to the other, including the quiet zone. Label Speed – The rate in inches or centimeters per second at which a label moves through the scan beam. Label Transitions – The transition of bars and spaces on a label, used by the MS-sensor to detect the presence of a label on a package. Ladder Label Orientation – A bar code label in which the bars are parallel to the label’s direction of travel. Match Code – The ability to compare bar code labels being scanned against a master label that is stored in the memory of the reader. Menu Configuration – The process of changing factory default settings via a sequence of menus displayed on a terminal monitor. Mil – One thousandths of an inch or 0.0254 mm. In bar-coding, a measurement that identifies a bar code label by the width of its narrowest element. Mismatch – An event that occurs when the scanned bar code label does not match the master label that is stored in the memory of the reader. Narrow-bar-width – The width of the narrowest bar of a given label, expressed in thousands of an inch (or mils). Non-volatile RAM (NOVRAM) – Random Access Memory that is available on power-on; that is, after power to the unit has been recycled. No Read – A non-read. A condition that occurs when the reader is set up to decode labels, and no labels are decoded during the read cycle. Number of Scans Calculation – The number of times a bar code label is scanned by the reader during one pass through the laser beam.

Publication 2755-6.9

Page 138

Glossary

G–3

Operational Commands – Serial commands from the host to the reader that control current operating parameters, counters, master label operations, and program management that are not stored in non-volatile RAM. Package Detector – A photo electric device used to sense to presence or absence of a package. Picket Fence Label Orientation – A bar code label in which the bars are perpendicular to the label’s direction of travel. Pitch – Label (or reader) rotation around the center a line perpendicular to the label’s bars. Point-to-Point – A protocol consisting of a single communications event, typically used to connect a bar code reader to a terminal or host computer. Port – Logical circuit for data entry and exit. (One or more ports may be included within a single connector.) Protocol – The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Quiet Zones – Specified “clear” (nonprinted) areas immediately before and after the bar code symbol. The area is usually white (for black and white bar code) and at least 10 times the width of the narrowest bar, as measured in thousands of an inch. The zones can be other than white as long as their densities remains consistent and they have the required contrast relative to the bars. RAM – Random Access Memory. Memory that is lost after power is recycled to the unit. Read Cycle – A programmed period of time or condition during which the reader will accept bar code label input. Reader – A scanning device that is comprised of a scan head and a decoder integrated in one package. Read Range – The distances in which a label can be reliably read, as measured from the front of the reader. See Depth of Field. Reflectance Threshold – A user-defined setting of reflection (a few digits higher than an empty space reading) that is a point-of-reference for the MS-sensor. A reading lower than the threshold indicates that a package is not present whereas a higher reading indicates the presence of a package.

Publication 2755-6.9

Page 139

G–4

Glossary

Relay Driver – A TTL signal sent by the reader. The output is determined by the relay driver selection (by operational command). ROM – Read Only Memory. Memory that cannot be changed. RS-232 – RS-232 defines an interface between two devices such as the reader and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line (pin 4). Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore, cable lengths are limited to a maximum of 50 feet (19.7 m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment. RS-422 – RS-422, unlike RS-232, measures signals differentially. The receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 ft (1219 m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line. It can be used wherever RS-232 is used. RS-485 – RS-485, like RS-422, can transmit up to 4000 ft (1219 m) using differential voltages but unlike RS-422, RS-485 transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in multidrop protocol. Scan Rate – Number of scans per second that the reader projects. Scan Width – That portion of the scan line in which a label can be read. Serial Commands – Online data strings (including configuration and operations) from a host or other terminal to the reader, that are always preceded by a < left angle bracket symbol and followed by a > right angle bracket symbol. Sinking/Sourcing – Describes a current signal flow relationship between field input and output devices in a control system and their power supply. A sourcing interface box supplies current (source) to a sinking field device (e.g., package detect). Skew – Label (or reader) rotation around the center of the skew axis. Spicular Reflection – The direct, mirror-like reflection of laser light back to the reader, causing over-light saturation.

Publication 2755-6.9

Page 140

Glossary

G–5

Symbology – A set of bar code symbols, such as Code 39 or Code 128, that have special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information. Tilt – Label (or reader) rotation around the centerline of the scan beam. Timeout – A user-selected period of time that ends a reader’s read cycle.

Publication 2755-6.9

Page 141

Rockwell Automation helps its customers receive a superior return on their investment by bringing together leading brands in industrial automation, creating a broad spectrum of easy-to-integrate products. These are supported by local technical resources available worldwide, a global network of system solutions providers, and the advanced technology resources of Rockwell.

Worldwide representation. Argentina • Australia • Austria • Bahrain • Belgium • Bolivia • Brazil • Bulgaria • Canada • Chile • China, People’s Republic of • Colombia • Costa Rica • Croatia • Cyprus Czech Republic • Denmark • Dominican Republic • Ecuador • Egypt • El Salvador • Finland • France • Germany • Ghana • Greece • Guatemala • Honduras • Hong Kong Hungary • Iceland • India • Indonesia • Iran • Ireland • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Macau • Malaysia • Malta • Mexico • Morocco The Netherlands • New Zealand • Nigeria • Norway • Oman • Pakistan • Panama • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic of • Spain • Sweden • Switzerland • Taiwan • Thailand • Trinidad • Tunisia • Turkey • United Arab Emirates United Kingdom • United States • Uruguay • Venezuela Rockwell Automation Headquarters, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 Rockwell Automation European Headquarters, Avenue Hermann Debroux, 46, 1160 Brussels, Belgium, Tel: (32) 2 663 06 00, Fax: (32) 2 663 06 40 Rockwell Automation Asia Pacific Headquarters, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 World Wide Web: http://www.ab.com

Publication 2755-6.9 – May 1997

40062-364-01 (B) Copyright 1997 Allen-Bradley Company,–Inc. Publication 2755-6.9 MayPrinted 1997in USA