For the Allen-Bradley 2755-LS7
Page 112
C
Appendix
ASCII Table This appendix provides ASCII characters.
ASCII Characters Dec.
Hex.
Mne.
Char.
Dec.
Hex.
Char.
Dec.
Hex.
Dec.
Hex.
40
Char. @
00
00
NUL
^@
32
20
SP
64
01
01
SOH
^A
33
21
!
65
02
02
STX
^B
34
22
“
03
03
ETX
^C
35
23
#
04
04
EOT
^D
36
24
05
05
ENQ
^E
37
25
06
06
ACK
^F
38
07
07
BEL
^G
08
08
BS
^H
09
09
HT
10
0A
LF
11
0B
12
0C
13
Char.
96
60
‘
41
A
97
61 a
66
42
B
98
62 b
67
43
C
99
63 c
$
68
44
D
100
64 d
%
69
45
E
101
65 e
26
&
70
46
F
102
66 f
39
27
'
71
47
G
103
67 g
40
28
(
72
48
H
104
68 h
^I
41
29
)
73
49
I
105
69 i
^J
42
2A
*
74
4A
J
106
6A j
VT
^K
43
2B
+
75
4B
K
107
6B k
FF
^L
44
2C
,
76
4C
L
108
6C l
0D
CR
^M
45
2D
–
77
4D
M
109
6D m
14
0E
SO
^N
46
2E
.
78
4E
N
110
6E n
15
0F
SI
^O
47
2F
/
79
4F
O
111
6F o
16
10
DLE
^P
48
30
0
80
50
P
112
70 p
17
11
DC1
^Q
49
31
1
81
51
Q
113
71 q
18
12
DC2
^R
50
32
2
82
52
R
114
72 r
19
13
DC3
^S
51
33
3
83
53
S
115
73 s
20
14
DC4
^T
52
34
4
84
54
T
116
74 t
21
15
NAK
^U
53
35
5
85
55
U
117
75 u
22
16
SYN
^V
54
36
6
86
56
V
118
76 v
23
17
ETB
^W
55
37
7
87
57
W
119
77 w
24
18
CAN
^X
56
38
8
88
58
X
120
78 x
25
19
EM
^Y
57
39
9
89
59
Y
121
79 y
26
1A
SUB
^Z
58
3A
:
90
5A
Z
122
7A z
27
1B
ESC
^[
59
3B
;
91
5B
[
123
7B
{
28
1C
FS
^\
60
3C
<
92
5C
\
124
7C
29
1D
GS
^]
61
3D
=
93
5D
]
125
7D
30
1E
RS
^^
62
3E
>
94
5E
^
126
7E
31
1F
US
^_
63
3F
?
95
5F
_
127
7F
| }
~
Publication 2755-6.9
Page 113
Appendix
D
Multidrop Communications This appendix describes the rules for setting up a concentrator or controller to communicate with a reader in standard Multidrop protocol.
Multidrop Addresses
Multidrop networks allow you to connect up to 50 readers to a single host via a concentrator or controller. Be aware of the following when setting up for multidrop communication. • No two readers in the multidrop network can have the same address. • Each reader in the network must have an address (from 1 to 50) assigned in its configuration program. • Each address has its own separate poll and select address (from 1C to 7F hex). Refer to the table on page D–2 for the poll and select addresses. Host
Concentrator or Controller Polled Protocol Multidrop Only RS-485 Interface (LAN) reader reader reader
Publication 2755-6.9
Page 114
D–2
Multidrop Communications
The poll and select addresses are listed in the table below.
Publication 2755-6.9
Reader
Poll Address
Select Address
Reader
Poll Address
Select Address
01
1C
1D
26
4E
4F
02
1E
1F
27
50
51
03
20
21
28
52
53
04
22
23
29
54
55
05
24
25
30
56
57
06
26
27
31
58
59
07
28
29
32
5A
5B
08
2A
2B
33
5C
5D
09
2C
2D
34
5E
5F
10
2E
2F
35
60
61
11
30
31
36
62
63
12
32
33
37
64
65
13
34
35
38
66
67
14
36
37
39
68
69
15
38
39
40
6A
6B
16
3A
3B
41
6C
6D
17
3C
3D
42
6E
6F
18
3E
3F
43
70
71
19
40
41
44
72
73
20
42
43
45
74
75
21
44
45
46
76
77
22
46
47
47
78
79
23
48
49
48
7A
7B
24
4A
4B
49
7C
7D
25
4C
4D
50
7E
7F
Page 115
Multidrop Communications
Polling Sequence
D–3
The polling sequence occurs when the host device solicits information from the readers. The host device sends out poll requests to the readers. The polling sequence example below begins with a RES (reset) from the controller followed by poll address 1E (ASCII hex value for reader 02) and a REQ (request). The reader responds by first transmitting its own address, 1E, followed by a STX (start of text) character, and then the data. Next it transmits an ETX (end of text) character and an LRC (longitudinal redundancy check) character. If the controller (or concentrator) receives the data from the reader and is able to validate it with an LRC calculation, it responds with an ACK (acknowledgment). If the reader in turn receives the ACK, the ends this successful exchange with a RES (reset).
Concentrator
Start of Sequence
End of Sequence
RES 1E REQ
ACK
Reader
1E STX DATA
ETXLRC
RES
Polling Reset A polling reset is when the polling sequence is interrupted. A polling reset occurs when: • the reader has no information and it responds by transmitting a RES (reset), • the reader receives a NAK instead of the ACK after transmitting its data string. The reader will re-attempt to transmit the data string up to three times. If the reader still does not receive an ACK, it will transmit a RES (reset) and discard the data in its buffers, or • the reader transmits data to the controller and the controller responds with an ACK or NAK, but the reader doesn’t receive the controller’s response. The reader will timeout and transmit a REQ to the controller and request another response. If after three retries (the number of times it transmits a REQ to the controller) the reader receives no response, it ends the transmission with a RES (reset).
Publication 2755-6.9
Page 116
D–4
Multidrop Communications
Select Sequence
Unlike poll requests, select commands always originate from the host device and consist of serial configuration or operation commands to devices that are configured in Multidrop. The reader complies with the command when it is polled during the cycle. A RES (reset) is the first command in the select sequence. The 1F hex is the select address associated with 02 address. It is followed by a REQ (request). The reader responds with its own select address, 1F hex, and an ACK (acknowledge). The controller then transmits an STX (start of text), the data (in this case a <T>), an ETX (end of text), and an LRC character. The reader replies by transmitting its own address, followed by an ACK, acknowledging receipt of the command. Upon receipt of an ACK, the controller concludes the successful exchange with a RES. In the example below, the reader only acknowledges a trigger counter request from the controller. The reader does not respond to the trigger counter request until a subsequent poll. For example, if the reader trigger count was 12 at the time the trigger counter request was received, on a subsequent poll the reader would transmit 02T/00012. (The 02 at the beginning of the string is the reader address.) Start of Sequence
Concentrator
End of Sequence
RES 1F REQ
02
STX <T> ETX LRC 1F ACK
RES 1F ACK
Select Reset If the reader receives bad data from the controller, it transmits a SEL (its select address) and a NAK to the controller. The controller re-transmits the data up to three times. The controller will end the sequence with a RES (reset) if no ACK is received.
Publication 2755-6.9