For the Allen-Bradley 2755-LS7

Page 112

C

Appendix

ASCII Table This appendix provides ASCII characters.

ASCII Characters Dec.

Hex.

Mne.

Char.

Dec.

Hex.

Char.

Dec.

Hex.

Dec.

Hex.

40

Char. @

00

00

NUL

^@

32

20

SP

64

01

01

SOH

^A

33

21

!

65

02

02

STX

^B

34

22

“

03

03

ETX

^C

35

23

#

04

04

EOT

^D

36

24

05

05

ENQ

^E

37

25

06

06

ACK

^F

38

07

07

BEL

^G

08

08

BS

^H

09

09

HT

10

0A

LF

11

0B

12

0C

13

Char.

96

60

‘

41

A

97

61 a

66

42

B

98

62 b

67

43

C

99

63 c

$

68

44

D

100

64 d

%

69

45

E

101

65 e

26

&

70

46

F

102

66 f

39

27

'

71

47

G

103

67 g

40

28

(

72

48

H

104

68 h

^I

41

29

)

73

49

I

105

69 i

^J

42

2A

*

74

4A

J

106

6A j

VT

^K

43

2B

+

75

4B

K

107

6B k

FF

^L

44

2C

,

76

4C

L

108

6C l

0D

CR

^M

45

2D

–

77

4D

M

109

6D m

14

0E

SO

^N

46

2E

.

78

4E

N

110

6E n

15

0F

SI

^O

47

2F

/

79

4F

O

111

6F o

16

10

DLE

^P

48

30

0

80

50

P

112

70 p

17

11

DC1

^Q

49

31

1

81

51

Q

113

71 q

18

12

DC2

^R

50

32

2

82

52

R

114

72 r

19

13

DC3

^S

51

33

3

83

53

S

115

73 s

20

14

DC4

^T

52

34

4

84

54

T

116

74 t

21

15

NAK

^U

53

35

5

85

55

U

117

75 u

22

16

SYN

^V

54

36

6

86

56

V

118

76 v

23

17

ETB

^W

55

37

7

87

57

W

119

77 w

24

18

CAN

^X

56

38

8

88

58

X

120

78 x

25

19

EM

^Y

57

39

9

89

59

Y

121

79 y

26

1A

SUB

^Z

58

3A

:

90

5A

Z

122

7A z

27

1B

ESC

^[

59

3B

;

91

5B

[

123

7B

{

28

1C

FS

^\

60

3C

<

92

5C

\

124

7C

29

1D

GS

^]

61

3D

=

93

5D

]

125

7D

30

1E

RS

^^

62

3E

>

94

5E

^

126

7E

31

1F

US

^_

63

3F

?

95

5F

_

127

7F

| }

~

Publication 2755-6.9

Page 113

Appendix

D

Multidrop Communications This appendix describes the rules for setting up a concentrator or controller to communicate with a reader in standard Multidrop protocol.

Multidrop Addresses

Multidrop networks allow you to connect up to 50 readers to a single host via a concentrator or controller. Be aware of the following when setting up for multidrop communication. • No two readers in the multidrop network can have the same address. • Each reader in the network must have an address (from 1 to 50) assigned in its configuration program. • Each address has its own separate poll and select address (from 1C to 7F hex). Refer to the table on page D–2 for the poll and select addresses. Host

Concentrator or Controller Polled Protocol Multidrop Only RS-485 Interface (LAN) reader reader reader

Publication 2755-6.9

Page 114

D–2

Multidrop Communications

The poll and select addresses are listed in the table below.

Publication 2755-6.9

Reader

Poll Address

Select Address

Reader

Poll Address

Select Address

01

1C

1D

26

4E

4F

02

1E

1F

27

50

51

03

20

21

28

52

53

04

22

23

29

54

55

05

24

25

30

56

57

06

26

27

31

58

59

07

28

29

32

5A

5B

08

2A

2B

33

5C

5D

09

2C

2D

34

5E

5F

10

2E

2F

35

60

61

11

30

31

36

62

63

12

32

33

37

64

65

13

34

35

38

66

67

14

36

37

39

68

69

15

38

39

40

6A

6B

16

3A

3B

41

6C

6D

17

3C

3D

42

6E

6F

18

3E

3F

43

70

71

19

40

41

44

72

73

20

42

43

45

74

75

21

44

45

46

76

77

22

46

47

47

78

79

23

48

49

48

7A

7B

24

4A

4B

49

7C

7D

25

4C

4D

50

7E

7F

Page 115

Multidrop Communications

Polling Sequence

D–3

The polling sequence occurs when the host device solicits information from the readers. The host device sends out poll requests to the readers. The polling sequence example below begins with a RES (reset) from the controller followed by poll address 1E (ASCII hex value for reader 02) and a REQ (request). The reader responds by first transmitting its own address, 1E, followed by a STX (start of text) character, and then the data. Next it transmits an ETX (end of text) character and an LRC (longitudinal redundancy check) character. If the controller (or concentrator) receives the data from the reader and is able to validate it with an LRC calculation, it responds with an ACK (acknowledgment). If the reader in turn receives the ACK, the ends this successful exchange with a RES (reset).

Concentrator

Start of Sequence

End of Sequence

RES 1E REQ

ACK

Reader

1E STX DATA

ETXLRC

RES

Polling Reset A polling reset is when the polling sequence is interrupted. A polling reset occurs when: • the reader has no information and it responds by transmitting a RES (reset), • the reader receives a NAK instead of the ACK after transmitting its data string. The reader will re-attempt to transmit the data string up to three times. If the reader still does not receive an ACK, it will transmit a RES (reset) and discard the data in its buffers, or • the reader transmits data to the controller and the controller responds with an ACK or NAK, but the reader doesn’t receive the controller’s response. The reader will timeout and transmit a REQ to the controller and request another response. If after three retries (the number of times it transmits a REQ to the controller) the reader receives no response, it ends the transmission with a RES (reset).

Publication 2755-6.9

Page 116

D–4

Multidrop Communications

Select Sequence

Unlike poll requests, select commands always originate from the host device and consist of serial configuration or operation commands to devices that are configured in Multidrop. The reader complies with the command when it is polled during the cycle. A RES (reset) is the first command in the select sequence. The 1F hex is the select address associated with 02 address. It is followed by a REQ (request). The reader responds with its own select address, 1F hex, and an ACK (acknowledge). The controller then transmits an STX (start of text), the data (in this case a <T>), an ETX (end of text), and an LRC character. The reader replies by transmitting its own address, followed by an ACK, acknowledging receipt of the command. Upon receipt of an ACK, the controller concludes the successful exchange with a RES. In the example below, the reader only acknowledges a trigger counter request from the controller. The reader does not respond to the trigger counter request until a subsequent poll. For example, if the reader trigger count was 12 at the time the trigger counter request was received, on a subsequent poll the reader would transmit 02T/00012. (The 02 at the beginning of the string is the reader address.) Start of Sequence

Concentrator

End of Sequence

RES 1F REQ

02

STX <T> ETX LRC 1F ACK

RES 1F ACK

Select Reset If the reader receives bad data from the controller, it transmits a SEL (its select address) and a NAK to the controller. The controller re-transmits the data up to three times. The controller will end the sequence with a RES (reset) if no ACK is received.

Publication 2755-6.9