Page 11

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

Table E LD8 Read Ranges ➀ Minimum Element Width ➁ Mils Millimeters 4 5 7.5 10 13 20 30 6 7.5 10 13 20 30 35 9 10 13 20 30 35 40 50

.10 .15 .19 .25 .33 .51 .76 .15 .19 .25 .33 .51 .76 .89 .23 .25 .38 .51 .76 .89 1.02 1.27

Inches

Read Range Centimeters

3.5 - 4.5 3.25 - 5.5 2.75 - 6.25 2.75 - 6.75 2.5 - 7.5 3.25 - 9.25 5.25 - 10.25 7.0 - 11.75 7.0 - 12.5 6.75 - 14.0 6.75 - 16.0 6.75 - 20.0 6.0 - 20.0 5.5 - 20.0 14.5 - 19.5 14.25 - 22.75 13.75 - 26.75 12.75 - 36.0 11.0 - 41.75 10.0 - 44.5 10.0 - 47.5 10.0 - 50.0

8.9 - 11.4 8.3 - 14.0 7.0 - 15.9 7.0 - 17.1 6.4 - 19.0 8.3 - 23.5 13.3 - 26.0 17.8 - 29.8 17.8 - 31.8 17.1 - 35.6 17.1 - 40.6 17.1 - 50.8 15.2 - 50.8 14.0 - 50.8 36.8 - 49.5 36.2 - 57.8 34.9 - 67.9 32.4 - 91.4 27.9 - 106.0 25.4 - 113.0 25.4 - 120.6 25.4 - 127.0

Catalog Number

2755-LD8A1 2755-LD8A4

2755-LD8B1 2755-LD8B4

2755-LD8C1 2755-LD8C4 ➂

➀ Read ranges are based on 4 character, Code 39 labels with a wide to narrow bar ratio of 2.6 to 1. and a print contrast ratio of .75 or better. Read ranges will vary with bar code symbol quality. ➁ For minimum element width, refer to ”Determining Apparent Minimum Element Width” on page 18. ➂ The glare that results from the laser striking reflective objects (conduit, metal conveyors) may affect performance of the LD8C scanner when used at long ranges. To minimize this effect, mask the area behind the symbol with a non-glossy material (flat black paint) or reduce the scan line to avoid reflective objects. Reducing the scan line will affect reading distances of the scanner.

11

Page 12

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

2755-LD8 Usable Beam Length

Figure 7 shows the Usable Beam Length versus Distance for the LD8 scanner. The black area is a no read area. The Usable Beam Length (bottom of chart) is compared to the Reading Distance (top of chart). The Usable Beam Length is approximately 20% less than the projected beam length (10% on each end of the scan line). The reading distance is measured from the scan window to the center of the symbol. Figure 7 LD8 Usable Beam Length ➀ LD8 Reading Distance ➁ Inches NA Centimeters NA

5 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

35 88.9

40 101.6

45 114.3

50 127.0

Usable Beam Length

Reading Distance

= Catalog No. 2755-LD8 = No Read Area

Inches NA Centimeters NA

3.3 8.4

5.5 14.1

7.8 19.7

10.0 25.3

12.2 30.9

14.4 36.6

16.6 42.2

18.8 47.8

21.0 53.4

23.3 59.1

Usable Beam Length (Nominal) ➀Usable Beam Length for LD8 Scanners = 0.443 x (Reading Distance + 2.5 inches) ➁Measured from the scan window to the center of the bar code symbol.

To estimate the Usable Beam Length:

• Determine the distance from the scan window to the center of the bar code symbol. This is your Reading Distance. • Locate your Reading Distance on Figure 7. The top of the chart displays the reading distances. The bottom of the chart displays nominal Usable Beam Lengths. 12

Page 13

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

Symbol Orientation

Bar code symbols must be in the correct orientation as they move by the scanner. The laser beam must cross every bar, space and quiet zone on the symbol in one sweep.

The orientation of the bar code symbol can be picket fence or step ladder. The orientation is determined by the symbol’s direction of travel relative to the scan line, not the horizontal or vertical orientation of the symbol. Figure 8 Picket Fence Orientation

Scanner Mounted Above Conveyor

Direction of Travel Direction of Travel

Scanner Mounted On Side of Conveyor

Figure 9 Step Ladder Orientation

Direction of Travel

Direction of Travel

Scanner Mounted On Side of Conveyor

Scanner Mounted Above Conveyor

13

Page 14

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

Calculating Scans/Symbol

This section explains how to calculate minimum scans per symbol for picket fence and step ladder applications.

Picket Fence Applications To calculate minimum scans per symbol for picket fence applications, use this formula: S = S = A = X = Y = Z =

A (X–Y) Z

Scans per Symbol (must be at least 5) Derated Scan Rate (nominal scan rate –5%) Usable Beam Length at Minimum Read Distance Symbol Length (including quiet zones) Conveyor Speed

Usable Beam Length, Symbol Length, and Conveyor Speed must be expressed in similar units. Calculations assume the scanner and decoder are triggered for the entire time the symbol is present and the symbol has a 0° pitch. (See ”Compensating for Pitched Symbols” on page 18.) Example 1: A 40 mil case code label that is 1 inch tall and 4.75 inches long (including quiet zones) is to be read in a picket fence orientation at 125 ft/min. Space is limited so the scanner must be positioned as close as possible to the labels. Since the 2755-LD8C1 scanner cannot read a 40 mil label until the scanner is 10 inches away, let’s assume that the 2755-LD4C1 scanner can read the label. At 6 inches, the LD4C1 scanner has a usable beam length of 5.525 inches. The following calculation converts Conveyor Speed to similar units (inches). 125 feet/minute x 12 inch/feet x 1 minute/60second = 25 inch/seconds

To calculate minimum scans per symbol for this application, insert these values into the formula: A = 200 scans/second – 5% = 190 scans/second (minimum scan rate) X = 5.525 inches Y = 4.75 inches Z = 25 inches/second S = 190 scans/second x (5.525 inches – 4.75 inches) / (25 inches / second) S = 5.89 scans

Since S (scans per symbol) is greater than 5 and the application uses good quality labels, the 2755-LD4C1 scanner is appropriate for this application.

14

Page 15

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

Example 2: Increasing the conveyor speed in Example 1 to 300 ft/min. decreases the number of scans per symbol to less than 3. This means the 2755-LD4C1 scanner is no longer appropriate. To increase the number of scans per symbol for picket fence applications, you can either:

• select a higher speed scanner • increase the usable beam length by backing the scanner away from the bar code symbol Selecting Higher Speed Scanner The LD8C1 scanner has a scan rate of 500 scans/second. It reads 40 mil labels at a minimum distance of 10 inches. At 10 inches, the LD8C1 has a usable beam length of 5.5 inches. To calculate minimum scans per symbol, use these values: A = 500 scans/second – 5% = 475 scans/second (minimum scan rate) X = 5.5 inches Y = 4.75 inches Z = 60 inches/second (equivalent to 300 ft/min. ) S = 475 scans/second x (5.5 inches – 4.75 inches) / (60 inches / second) S = 5.94 scans

Since S (scans per symbol) is greater than 5 and the application uses good quality labels, the 2755-LD8C1 scanner is appropriate for this application. Increasing Usable Beam Length The LD4C1 scanner at 10 inches produces a usable beam length of 8.1 inches. Minimum scans per symbol are now calculated using these values. A = 200 scans/second – 5% = 190 scans/second (minimum scan rate) X = 8.1 inches Y = 4.75 inches Z = 60 inches/second (equivalent to 300 ft/min. ) S = 190 scans/second x (8.1 inches – 4.75 inches) / (60 inches / second) S = 10.6 scans

Because of the increased scan angle of the LD4, some picket fence applications can be performed with a higher number of reads using the lower speed scanner.

15

Page 16

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

Calculating Scans/Symbol

Step Ladder Applications To calculate minimum scans per symbol for step ladder applications, use this formula: S = S = A = H= Z =

AxH Z

Scans per Symbol (must be at least 5) Derated Scan Rate (nominal scan rate –5%) Symbol Height (length of bars of symbol) Conveyor Speed

Conveyor Speed and Symbol Height must be expressed in similar units. Calculations assume that the scanner and decoder are triggered for the entire time the symbol is present and the symbol has a 0° pitch. (See the section on Compensating for Pitched Symbols.) Example 1: A 40 mil case code label that is 1 inch tall and 4.75 inches long is to be read in step ladder orientation at 125 ft/min. Space is limited so the scanner must be positioned as close as possible to the labels. Since the 2755-LD8C1 cannot read a 40 mil label unless the scanner is 10 inches away, let’s assume the 2755-LD4C1 scanner can read the label. The usable beam must be long enough to cover the entire symbol including quiet zones. At 6 inches, the LD4C1 scanner has a usable beam length of 5.525 inches. The calculation below converts Conveyor Speed to similar units (inches). 125 feet/minute x 12 inch/feet x 1 minute/60second = 25 inch/second

To calculate minimum scans per symbol for this step ladder application, use the following values: A = 200 scans/second – 5% = 190 scans/second (minimum scan rate) H = 1 inch Z = 25 inches/second S = 190 scans/second x 1 inch / (25 inches / second) S = 7.6 scans

Since S (scans per symbol) is greater than 5 and the application uses good quality labels, the 2755-LD4C1 scanner is appropriate for this step ladder application.

16

Page 17

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

Example 2: Increasing the conveyor speed in Example 1 to 300 ft/min. decreases the minimum number of scans per symbol to approximately 3. This value is below the recommended value of 5 scans per symbol making the 2755-LD4C1 inappropriate. The label would have to be at least 1.6 inches tall to be read by an LD4 scanner. To increase the number of scans per symbol for step ladder applications, you can select a higher speed scanner or increase the height of the symbol. Selecting Higher Speed Scanner The LD8C1 scanner has a scan rate of 500 scans/second. It reads 40 mil labels at a minimum distance of 10 inches. To calculate the minimum number of scans per symbol use these values: A = 500 scans/second –5% = 475 scans/second (minimum scan rate) H = 1 inch Z = 60 inches/second (equivalent to 300 ft/min. ) S = 475 scans/second x 1 inch / (60 inches / second) S = 7.9 scans

Since S (scans per symbol) is greater than 5 and the application uses good quality labels, the 2755-LD8C1 scanner is appropriate for this step ladder application. Because of the increased speed of the LD8 scanners, most high speed step ladder applications will use this scanner.

17

Page 18

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

Compensating for Pitched Symbols

You must consider the following when attempting to read symbols that are pitched:

• The apparent minimum element width • The nearest and farthest code elements must be within the scanner’s read range.

Determining Apparent Minimum Element Width When a symbol is pitched, the bars appear to be narrower and closer to one another. This apparent element width is a reduction of the actual element width. Before positioning the scanner using the read ranges in Figure 3 or 6, determine the symbol’s apparent minimum element width. Note: If the symbol has narrow spaces that are smaller than the narrow bars, base the read range on the narrow spaces. Figure 10 shows two boxes, each containing the same bar code symbol. Below each box is an exaggerated view of 5 elements (3 black, 2 white) as seen from the top down. Figure 10 Actual vs Apparent Element Width Apparent Element Width 10 mil (.25 mm) Pitch

Apparent Element Width 8.6 mil (.22 mm) Pitch Pitched

Actual Element Widths 10 mils

Actual Element Widths 10 mils

Apparent Element Widths 10 mils

18

Apparent Element Widths 8.6 mils

Page 19

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

For example, a 10 mil (0.25 mm) symbol with pitch can be scanned at 17 inches (43.2 cm) with a Catalog No. 2755-LD8C1 scanner. If you pitch the symbol and determine the apparent minimum element width using the formula below, the apparent element width is 8.6 mils (0.22 mm). Apparent Minimum Element Width = Actual Element Width x Cosine (Pitch Angle) In the above example, the following conditions apply: Actual Element Width = 10 mil (0.25 mm) Pitch Angle = Therefore: 10 x (cos = 8.6 mil (0.22 mm) The minimum recommended bar width that the Catalog No. 2755-LD8C1 scanner can read is 9 mil (0.23 mm). Because of the pitch of the symbol, you need to use the Catalog No. 2755-LD8B1 scanner. However, the distance between the scanner and the symbol is decreased. The maximum read range of the Catalog No. 2755-LD8B1 scanner for a 8.6 mil symbol is 13 inches (33 cm). In summary, increasing the pitch of the symbol decreases the apparent minimum element width. Figure 11 illustrates the above example. Figure 11 Effect of Pitch on Read Range Mils Millimeters

50 1.27

Apparent Minimum Element Width

45 1.14

40 1.02

35 .89

C

30 .76

25 .64

20 .51

B

15 .38

10 .25

10 mil (0.25mm) symbol with 0° pitch.

A

10 mil (0.25 mm) symbol with pitch yields apparent minimum element width of 8.6 mil (0.22 mm).

5 .13

Inches 5 Centimeters 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

35 88.9

40 101.6

45 114.3

50 127.0

Read Range (from scan window) 19

Page 20

Product Data Bulletin 2755 High Performance, Visible Laser Diode Scanners

Compensating for Pitched Symbols

Code Element Distance The nearest and farthest elements of a pitched symbol must be within the minimum and maximum reading distance of the scanner. Centering the symbol within the scanner’s read range helps to prevent pitched symbols from exceeding the read range limits. You can still exceed the read range with a pitched symbol. See Figures 12 and 13. Figure 12 Read Range and Symbol Resolution at Pitch 18 inches (45.7 cm)

3 inch (7.6 cm) symbol is pitched The center of the symbol is 18 inches (45.7 cm) from the scan window. Element width = 20 mils (.51mm) 2755-LD4B1 Symbol’s Nearest and Farthest Elements are 18 inches (45.7 cm) Mils Millimeters

50 1.27

Apparent Minimum Element Width

45 1.14

40 1.02

35 .89

C

30 .76

25 .64

The center of the 3 inch (7.6 cm) symbol is positioned 18 inches (45.7 cm) from the scan window.

B

20 .51

The 2755-LD4B1 scanner is appropriate for this application.

15 .38

10 .25

A

5 .13

Inches 5 Centimeters 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

Read Range (from scan window) 20

35 88.9

40 101.6

45 114.3

50 127.0