Page 33

Chapter

A–B

6

Maintenance and Troubleshooting Chapter Objectives

Maintenance procedures are stated and troubleshooting charts are provided in this chapter.

Maintaining the Equipment

! Scan Window Removal

WARNING: No user maintenance of the scan head is required. Do not open the enclosure.

The scan window fits into an opening on the side of the scan head. A gasketed cover is then tightly secured over the window to ensure a NEMA 4 rating. To remove the scan window: 1. Remove the four Phillips head screws from the cover. 2.Lift the cover away from the scan head. Make sure the scan window does not fall out. Handle the scan window by the edges to avoid finger prints. Refer to Figure 6.1. Figure 6.1 Scan Window Removal

6–1

Page 34

Chapter 6 Maintenance and Troubleshooting

Cleaning the Glass Window

Do not use abrasive materials, such as disposable paperwipes, to clean the glass scan window. Most disposable wipes, or paper towels, use glass fibers which will scratch and cloud the window. Instead, use the following materials: Air: Optics rated clean air Solvent: Optics rated cleaning solution for use on coated lenses Wipe: Optics quality lens cleaning paper and cotton–tipped swabs. Use the following procedure to clean the glass scan window:

!

CAUTION: Do not use abrasive materials, such as disposable paper wipes, to clean the glass scan window. In most cases, they contain glass fibers that will scratch and cloud the window.

Step 1 Turn the decoder OFF. Step 2 Check that the PWR ON indicators on both the decoder and scan head are OFF. Step 3 Use the lens cleaning paper to wipe any dust or foreign material from the window. Be careful not to scratch the window with any grit that might be on the window. Step 4 Dust off the scan window and adjacent areas with optics rated air. Step 5 Remove the scan window. Figure 6.1 illustrates the removal.

!

CAUTION: Do not touch the internal mirrors! Smudge from finger prints will diffuse the beam.

Step 6 Clean the window using the optics rated cleaning solution, cotton–tipped swabs and lens cleaning paper. To avoid smearing film and fingerprints, rotate the cotton–tipped swab, while it’s on the glass, nearly one full turn. Then, discard it. Step 7 Replace the scan window. Step 8 Turn the decoder ON. The PWR ON indicators on both the decoder and scan head should be ON. When the window is clean, you will barely be able to see the reflection of the laser beam on the clear glass. 6–2

Page 35

Chapter 6 Maintenance and Troubleshooting

Cleaning the Plastic Window

Do not use abrasive materials, such as disposable paper wipes, to clean the plastic scan window. Most disposable wipes, or paper towels, use glass fibers which will scratch and cloud the window. Instead, use the following materials: Air: Optics rated clean air Solvent: Optics rated cleaning solution for use on coated lenses Wipe: Optics quality lens cleaning paper and cotton–tipped swabs. Use the following procedure to clean the glass scan window:

!

CAUTION: Do not use organic solvents or abrasive materials, such as disposable paper wipes, to clean the plastic scan window. In most cases, they contain glass fibers that will scratch and cloud the window.

Step 1 Turn the decoder OFF. Step 2 Check that the PWR ON indicators on both the decoder and scan head are OFF. Step 3 Use the lens cleaning paper to wipe any dust or foreign material from the window. Be careful not to scratch the window with any grit that might be on the window. Step 4 Dust off the scan window and adjacent areas with optics rated air. Step 5 Remove the scan window. Figure 6.1 illustrates the removal.

!

CAUTION: Do not touch the internal mirrors! Smudge from finger prints will diffuse the beam.

Step 6 Clean the window using the optics rated cleaning solution, cotton–tipped swabs and lens cleaning paper. To avoid smearing film and fingerprints, rotate the cotton–tipped swab, while it’s on the glass, nearly one full turn. Then, discard it. Step 7 Replace the scan window. Step 8 Turn the decoder ON. The PWR ON indicators on both the decoder and scan head should be ON. When the window is clean, you will barely be able to see the reflection of the laser beam on the clear glass. 6–3

Page 36

Chapter 6 Maintenance and Troubleshooting

Troubleshooting the System Problem

Possible Solution

Decoder is not turned ON.

Turn decoder ON.

Improper connection to power supply.

Reconnect power cord to source.

Line fuse on decoder is blown.

Replace fuse on decoder.

Faulty power cord or switch.

Check that voltage is present at service outlet.

No incoming power.

Check that voltage is present at service outlet.

Interconnect cable between decoder and scan head is loose.

Reconnect cable and check connections.

Interconnect cable is defective.

Replace cable.

Scan head or decoder is defective.

Replace scan head.

Laser ON/OFF toggle switch is in OFF position.

Check Laser ON/OFF toggle switch position.

No scan trigger signal.

Verify sending of scan trigger by either package detect or trigger from decoder.

Improperly positioned labels.

Check that reading distance is correct and orientation of labels to scan head is correct.

Poor quality labels.

Check that labels are good quality and within specifications.

Laser ON/OFF toggle switch is in OFF position.

Check Laser ON/OFF toggle switch position.

Decoder is improperly programmed.

Refer to the appropriate User’s Manual.

Loose cables or connections.

Check cables and connections.

Scan Window is dirty

Clean window. Refer to Chapter 6

Laser beam expands and contracts.

Scan head is not securely mounted.

Improve mounting.

Warning!

Laser scanning mechanism is not operating correctly.

Turn laser OFF using toggle switch on back of scanner, then turn decoder OFF.

PWR ON indicators on both scan head and decoder do not light.

PWR ON indicator on scan head does not light, but PWR ON indicator on decoder is lit.

No laser beam emitted from window of scan head

Unable to read a label.

Laser beam is an intense dot of light.

6–4

Probable Cause