The text of a manual · part 3 of 9
Bulletin 2755 Industrial Medium and High-Speed Bar Code Scanners User Manual: 2 - Product Description
Pages 8 to 13 of 53, from Bulletin 2755 Industrial Medium and High-Speed Bar Code Scanners User Manual
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-L7 and Allen-Bradley 2755-L9
Page 8
Chapter
A–B
2
Product Description Chapter Objectives
The capabilities of the scan head are described when connected to a Catalog No. 2755–DM9 Decoder.
Overview
The Industrial Medium and High Speed Bar Code Scanners are moving beam, bar code scan heads designed for use with the Catalog No. 2755–DM9 Decoder. The scanners are available as shown:
• Side scanning (Catalog No. 2755–L7Sx①, –L9Sx①) • Side Raster scanning (Catalog No. 2755–L7Rx①, –L9Rx①) ① The x stands for the different range selections of each scanner. Refer to Figures 2.2 and 2.3.
Scanning is bidirectional at approximately 350 scans per second with an L7, Industrial Medium–Speed Bar Code Scanner and 800 scans per second with an L9, Industrial High–Speed Bar Code Scanner. Depending on the scanner used, symbols can be scanned as near as 3.5 inches (8.9 cm) and as far as 50 inches (127 cm) away. Figure 2.1 Side Scanning and Raster Scanning
90–105–9
The side scanning model reflects the scanning beam out of the side of the NEMA 4 case. The raster scanning model uses a stepping raster motor to project what appears to be a number of parallel beams out the side of the unit. This type of scan head is useful when attempting to scan poor quality labels, or labels that may not always be in exactly the same place. 2–1
Page 9
Chapter 2 Product Description
L7 Reading Ranges
Figure 2.2 illustrates the average reading ranges, relative to the symbol’s minimum bar width, that you should expect when using an L7 scanner with your Catalog No. 2755–DM9 Decoder. Figure 2.2 Average Scan Range vs. Minimum Bar Width for L7 Scanner Minimum Bar Width Mils 50 Millimeters 1.27 45 1.14 40 1.02 35 .89 30 .76 25 .64 2755–L7SC 2755–L7RC
20 .51 15 .38
2755–L7SD 2755–L7RD
10 .25
2755–L7SB 2755–L7RB
5 .13
2755–L7SA 2755–L7RA
Inches 5 Centimeters12.7
10 25.4
15 20 25 30 35 40 45 50 38.1 50.8 63.5 76.2 88.9 101.6 114.3 127.0 Scan Range (from face of scanner)①
°
°
① Scan Range will vary with symbol quality, pitch and skew. This application was based on no more than 5 pitch and 30 skew, with full scan beam (Figure 5.3). Refer to Chapter 3, Installation Considerations when reading labels with more than 20 pitch.
°
The following table compares the minimum bar width to the scan range of each catalog number. Minimum Bar Width
Scan Range①
Catalog Number
Mils mm
Inches
Centimeters
Side Scanning
Raster Scanning
7.5 10 20
.19 .25 .51
6.5 – 8.5 6.0 – 9.0 5.0 – 11.0
16.5 – 21.6 15.2 – 22.9 12.7 – 27.9
2755–L7SA①
2755–L7RA①
11 20 25
.28 .51 .64
8.5 – 13.5 5.5 – 19.0 3.5 – 22.0
21.6 – 34.3 14.0 – 48.3 8.9 – 55.9
2755–L7SB
2755–L7RB
16 25 35
.41 .64 .89
10 – 23 8 – 29 6 – 35
25.4 – 58.4 20.3 – 73.7 15.2 – 88.9
2755–L7SD
2755–L7RD
20 35 50
.51 .89 1.27
16 – 35 8 – 50 8 – 50
40.6 – 88.9 20.3 – 127 20.3 – 127
2755–L7SC
2755–L7RC
① When using ‘‘A’’ range scanners to read labels with high paper noise, increasing the skew to will enhance performance.
2–2
Page 10
Chapter 2 Product Description
L9 Reading Ranges
Figure 2.3 illustrates the average reading ranges, relative to the symbol’s minimum bar width, that you should expect when using an L9 scanner with your Catalog No. 2755–DM9 Decoder. Figure 2.3 Average Scan Range vs. Minimum Bar Width for L9 Scanner Minimum Bar Width Mils 35 Millimeters .89 30 .76 25 .64 20 .51 2755–L9SD 2755–L9RD
15 .38 10 .25
2755–L9SB 2755–L9RB 2755–L9SA 2755–L9RA
5 .13
10 25.4
Inches 5 Centimeters 12.7
15 38.1
20 50.8
25 63.5
30 76.2
35 88.9
Scan Range (from face of scanner) ① ① Scan Range will vary with symbol quality, pitch and skew. This application was based on no more than 5°pitch and 30° skew, with full scan beam (Figure 5.3). Refer to Chapter 3, Installation Considerations when reading labels with more than 20° pitch.
The following compares the minimum bar width to the scan range of each catalog number. Minimum Bar Width
Scan Range②
Catalog Number
Mils mm
Inches
Centimeters
Side Scanning
Raster Scanning
7.5 10 20
.19 .25 .51
6.5 – 8.5 6.0 – 9.0 5.0 – 11.0
16.5 – 21.6 15.2 – 22.9 12.7 – 27.9
2755–L9SA①
2755–L9RA①
11 20 25
.28 .51 .64
10 – 13.5 9 – 16 8.5 – 18
25.4 – 34.3 22.9 – 40.6 21.6 – 45.7
2755–L9SB
2755–L9RB
16 25 35
.41 .64 .89
10.5 – 21.5 9.0 – 25.5 7.5 – 30③
26.7 – 54.6 22.9 – 64.8 19.1 – 76.2③
2755–L9SD
2755–L9RD
② Scan range will vary with symbol quality. This application was based on no more than 5° pitch and 30° skew with full scan beam (Figure 5.3). Refer to Chapter 3, Installation Considerations when reading labels with more than 20° pitch. ③ Scan range may be reduced when using low contrast labels.
2–3
Page 11
Chapter 2 Product Description
Features
Laser Shut Off – Use this switch to enable/disable the laser beam without interrupting power. The upward position (ON) enables the laser, the downward position (OFF) disables the laser beam. The use of this feature is covered in Chapter 5, Operation. LED indicators – There are two LEDs on the back of the scan head, Power On and Valid Read. They are defined in Figure 2.4. Figure 2.4 Scan Head Features
NEMA 4 Case – Both the L7 and L9 scan heads are housed in gasketed, NEMA 4, aluminum cases. Replaceable Scan Windows – You can easily remove and replace the scan windows. Both the L7 and L9 scan heads are shipped with coated, optical quality, glass windows. Coated, low loss, optical quality, plastic windows are also available for special applications, or when required by FDA regulations. The use of this feature is covered in Chapter 6, Maintenance and Troubleshooting. Package Detector Port – Connect the optional Package Detector Assembly (Catalog No. 2755–NP3, or NP5) to this port to allow the scan head to be turned on only when there is a package present. The use of this feature is covered in Chapter 4, Installation. Scan Width Adjustment – This four position switch is located behind a gasketed 1/4–20 screw. Rotate this switch, using the supplied tool, to set the scan width to one of four settings: full, , , . Examples of this feature are covered in Chapter 5, Operation. Raster Height Adjustment – This four position switch is located behind a gasketed 1/4–20 screw. Rotate this four position switch to increase/decrease the height of your raster scanning pattern (on L7R and L9R only). Examples of this feature are covered in Chapter 5, Operation. 2–4
Page 12
Chapter 2 Product Description
Figure 2.5 Scan Head Features
Cabling
Scanner to Decoder cables are sold separately. Refer to Table 2.C for information necessary to order the proper cable.
Accessories
Several accessories are available to provide installation and operational flexibility, including:
• Package Detector Assembly – This assembly consists of a Package Detector Switch and a reflector. This switch indicates to the decoder that a package is present.
• Mounting hardware – A swivel ball mounting base is available for use with a flat mounting plate or “T” Mounting plate.
• Replaceable Windows – Replaceable, optical quality, glass and plastic windows are available.
2–5
Page 13
Chapter 2 Product Description
The following table lists system accessories.
Catalog Number
Item
Description
2755–NP3
Long Range Package Detector Assembly
An infrared photoelectric switch and reflector. For the detection of packages up to a maximum of 18 feet (5.5 m) away.
2755–NP5
Short Range Package Detector Assembly
A visible red photoelectric switch and reflector. For the detection of packages up to a maximum 10 feet (3 m) away.
2755–NC9
Package Detector Port Connector
Connects user–supplied photoelectric switch to scan head. Accepts cables with .190 to .312 inches (4.8 to 7.9 mm) outer jacket diameter.
2755–NM1
Swivel Mounting Base
2755–NM2
“T” Mounting Plate
Mounts Swivel Mounting Base (Catalog No. 2755–NM1) to scan head.
2755–NM3
Flat Mounting Plate
Attach this plate to scan head in order to use your own brackets, or to use the Swivel Mounting Base (Catalog No. 2755–NM1) when you want the swivel ball close to the base of the scan head.
2755–CL10
10 foot (3 meter) Cable
Connects scanner to Catalog No. 2755–DM9 Decoder.
2755–CL25
25 foot (7.6 meter) Cable
Connects scanner to Catalog No. 2755–DM9 Decoder.
Universal swivel ball mount for greater installation flexibility. Must be used with “T” Mounting Plate or Flat Mounting Plate.
W77121–800–01① Replacement Glass Window Kit
Anti–reflective, optical glass replacement window.
W77121–800–02① Replacement Plastic Window Kit
Hard coated, anti–reflective, optical quality, plastic replacement window.
W77121–802–01① Caution & Warning Label Kit (English Only)
2755–L7, L9 - 5 sets per package.
W77121–802–02① Caution & Warning Label Kit (Alternate Language)
2755–L7, L9 - 1 set each in German, French, Italian, Spanish.
① Replacement part number.
2–6