Bulletin 2755 Industrial Medium and High-Speed Bar Code Scanners User Manual: 2 - Product Description

Pages 8 to 13 of 53, from Bulletin 2755 Industrial Medium and High-Speed Bar Code Scanners User Manual

The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-L7 and Allen-Bradley 2755-L9

Page 8

Chapter

A–B

2

Product Description Chapter Objectives

The capabilities of the scan head are described when connected to a Catalog No. 2755–DM9 Decoder.

Overview

The Industrial Medium and High Speed Bar Code Scanners are moving beam, bar code scan heads designed for use with the Catalog No. 2755–DM9 Decoder. The scanners are available as shown:

• Side scanning (Catalog No. 2755–L7Sx①, –L9Sx①) • Side Raster scanning (Catalog No. 2755–L7Rx①, –L9Rx①) ① The x stands for the different range selections of each scanner. Refer to Figures 2.2 and 2.3.

Scanning is bidirectional at approximately 350 scans per second with an L7, Industrial Medium–Speed Bar Code Scanner and 800 scans per second with an L9, Industrial High–Speed Bar Code Scanner. Depending on the scanner used, symbols can be scanned as near as 3.5 inches (8.9 cm) and as far as 50 inches (127 cm) away. Figure 2.1 Side Scanning and Raster Scanning

90–105–9

The side scanning model reflects the scanning beam out of the side of the NEMA 4 case. The raster scanning model uses a stepping raster motor to project what appears to be a number of parallel beams out the side of the unit. This type of scan head is useful when attempting to scan poor quality labels, or labels that may not always be in exactly the same place. 2–1

Page 9

Chapter 2 Product Description

L7 Reading Ranges

Figure 2.2 illustrates the average reading ranges, relative to the symbol’s minimum bar width, that you should expect when using an L7 scanner with your Catalog No. 2755–DM9 Decoder. Figure 2.2 Average Scan Range vs. Minimum Bar Width for L7 Scanner Minimum Bar Width Mils 50 Millimeters 1.27 45 1.14 40 1.02 35 .89 30 .76 25 .64 2755–L7SC 2755–L7RC

20 .51 15 .38

2755–L7SD 2755–L7RD

10 .25

2755–L7SB 2755–L7RB

5 .13

2755–L7SA 2755–L7RA

Inches 5 Centimeters12.7

10 25.4

15 20 25 30 35 40 45 50 38.1 50.8 63.5 76.2 88.9 101.6 114.3 127.0 Scan Range (from face of scanner)①

°

°

① Scan Range will vary with symbol quality, pitch and skew. This application was based on no more than 5 pitch and 30 skew, with full scan beam (Figure 5.3). Refer to Chapter 3, Installation Considerations when reading labels with more than 20 pitch.

°

The following table compares the minimum bar width to the scan range of each catalog number. Minimum Bar Width

Scan Range①

Catalog Number

Mils mm

Inches

Centimeters

Side Scanning

Raster Scanning

7.5 10 20

.19 .25 .51

6.5 – 8.5 6.0 – 9.0 5.0 – 11.0

16.5 – 21.6 15.2 – 22.9 12.7 – 27.9

2755–L7SA①

2755–L7RA①

11 20 25

.28 .51 .64

8.5 – 13.5 5.5 – 19.0 3.5 – 22.0

21.6 – 34.3 14.0 – 48.3 8.9 – 55.9

2755–L7SB

2755–L7RB

16 25 35

.41 .64 .89

10 – 23 8 – 29 6 – 35

25.4 – 58.4 20.3 – 73.7 15.2 – 88.9

2755–L7SD

2755–L7RD

20 35 50

.51 .89 1.27

16 – 35 8 – 50 8 – 50

40.6 – 88.9 20.3 – 127 20.3 – 127

2755–L7SC

2755–L7RC

① When using ‘‘A’’ range scanners to read labels with high paper noise, increasing the skew to will enhance performance.

2–2

Page 10

Chapter 2 Product Description

L9 Reading Ranges

Figure 2.3 illustrates the average reading ranges, relative to the symbol’s minimum bar width, that you should expect when using an L9 scanner with your Catalog No. 2755–DM9 Decoder. Figure 2.3 Average Scan Range vs. Minimum Bar Width for L9 Scanner Minimum Bar Width Mils 35 Millimeters .89 30 .76 25 .64 20 .51 2755–L9SD 2755–L9RD

15 .38 10 .25

2755–L9SB 2755–L9RB 2755–L9SA 2755–L9RA

5 .13

10 25.4

Inches 5 Centimeters 12.7

15 38.1

20 50.8

25 63.5

30 76.2

35 88.9

Scan Range (from face of scanner) ① ① Scan Range will vary with symbol quality, pitch and skew. This application was based on no more than 5°pitch and 30° skew, with full scan beam (Figure 5.3). Refer to Chapter 3, Installation Considerations when reading labels with more than 20° pitch.

The following compares the minimum bar width to the scan range of each catalog number. Minimum Bar Width

Scan Range②

Catalog Number

Mils mm

Inches

Centimeters

Side Scanning

Raster Scanning

7.5 10 20

.19 .25 .51

6.5 – 8.5 6.0 – 9.0 5.0 – 11.0

16.5 – 21.6 15.2 – 22.9 12.7 – 27.9

2755–L9SA①

2755–L9RA①

11 20 25

.28 .51 .64

10 – 13.5 9 – 16 8.5 – 18

25.4 – 34.3 22.9 – 40.6 21.6 – 45.7

2755–L9SB

2755–L9RB

16 25 35

.41 .64 .89

10.5 – 21.5 9.0 – 25.5 7.5 – 30③

26.7 – 54.6 22.9 – 64.8 19.1 – 76.2③

2755–L9SD

2755–L9RD

② Scan range will vary with symbol quality. This application was based on no more than 5° pitch and 30° skew with full scan beam (Figure 5.3). Refer to Chapter 3, Installation Considerations when reading labels with more than 20° pitch. ③ Scan range may be reduced when using low contrast labels.

2–3

Page 11

Chapter 2 Product Description

Features

Laser Shut Off – Use this switch to enable/disable the laser beam without interrupting power. The upward position (ON) enables the laser, the downward position (OFF) disables the laser beam. The use of this feature is covered in Chapter 5, Operation. LED indicators – There are two LEDs on the back of the scan head, Power On and Valid Read. They are defined in Figure 2.4. Figure 2.4 Scan Head Features

NEMA 4 Case – Both the L7 and L9 scan heads are housed in gasketed, NEMA 4, aluminum cases. Replaceable Scan Windows – You can easily remove and replace the scan windows. Both the L7 and L9 scan heads are shipped with coated, optical quality, glass windows. Coated, low loss, optical quality, plastic windows are also available for special applications, or when required by FDA regulations. The use of this feature is covered in Chapter 6, Maintenance and Troubleshooting. Package Detector Port – Connect the optional Package Detector Assembly (Catalog No. 2755–NP3, or NP5) to this port to allow the scan head to be turned on only when there is a package present. The use of this feature is covered in Chapter 4, Installation. Scan Width Adjustment – This four position switch is located behind a gasketed 1/4–20 screw. Rotate this switch, using the supplied tool, to set the scan width to one of four settings: full, , , . Examples of this feature are covered in Chapter 5, Operation. Raster Height Adjustment – This four position switch is located behind a gasketed 1/4–20 screw. Rotate this four position switch to increase/decrease the height of your raster scanning pattern (on L7R and L9R only). Examples of this feature are covered in Chapter 5, Operation. 2–4

Page 12

Chapter 2 Product Description

Figure 2.5 Scan Head Features

Cabling

Scanner to Decoder cables are sold separately. Refer to Table 2.C for information necessary to order the proper cable.

Accessories

Several accessories are available to provide installation and operational flexibility, including:

• Package Detector Assembly – This assembly consists of a Package Detector Switch and a reflector. This switch indicates to the decoder that a package is present.

• Mounting hardware – A swivel ball mounting base is available for use with a flat mounting plate or “T” Mounting plate.

• Replaceable Windows – Replaceable, optical quality, glass and plastic windows are available.

2–5

Page 13

Chapter 2 Product Description

The following table lists system accessories.

Catalog Number

Item

Description

2755–NP3

Long Range Package Detector Assembly

An infrared photoelectric switch and reflector. For the detection of packages up to a maximum of 18 feet (5.5 m) away.

2755–NP5

Short Range Package Detector Assembly

A visible red photoelectric switch and reflector. For the detection of packages up to a maximum 10 feet (3 m) away.

2755–NC9

Package Detector Port Connector

Connects user–supplied photoelectric switch to scan head. Accepts cables with .190 to .312 inches (4.8 to 7.9 mm) outer jacket diameter.

2755–NM1

Swivel Mounting Base

2755–NM2

“T” Mounting Plate

Mounts Swivel Mounting Base (Catalog No. 2755–NM1) to scan head.

2755–NM3

Flat Mounting Plate

Attach this plate to scan head in order to use your own brackets, or to use the Swivel Mounting Base (Catalog No. 2755–NM1) when you want the swivel ball close to the base of the scan head.

2755–CL10

10 foot (3 meter) Cable

Connects scanner to Catalog No. 2755–DM9 Decoder.

2755–CL25

25 foot (7.6 meter) Cable

Connects scanner to Catalog No. 2755–DM9 Decoder.

Universal swivel ball mount for greater installation flexibility. Must be used with “T” Mounting Plate or Flat Mounting Plate.

W77121–800–01① Replacement Glass Window Kit

Anti–reflective, optical glass replacement window.

W77121–800–02① Replacement Plastic Window Kit

Hard coated, anti–reflective, optical quality, plastic replacement window.

W77121–802–01① Caution & Warning Label Kit (English Only)

2755–L7, L9 - 5 sets per package.

W77121–802–02① Caution & Warning Label Kit (Alternate Language)

2755–L7, L9 - 1 set each in German, French, Italian, Spanish.

① Replacement part number.

2–6