Page 49

3–10

Configuring the Scanner

Code 39 Options (Continued) Send Transmission Buffer Sends the contents of the Code 39 transmission buffer. You will hear a low/high beep after the buffer has been sent. You can also send the contents of the Code 39 buffer by scanning any Code 39 label with any leading character other than a space. If you attempt to transmit an empty buffer, the scanner will provide a short low/high/low beep. Code 39 Full ASCII The full ASCII option allows the scanner to output any ASCII character or control code (including non-printable characters). When enabled, the scanner interprets some characters ($, +, %, /) as special control codes. Refer to Appendix E for a list of the Code 39 Full ASCII codes. For example, scanning a symbol $H results in the ASCII code for a Backspace being transmitted. Note: The scanner cannot autodiscriminate between Code 39 and Code 39 Full ASCII symbols.

Publication 2755-6.2

Page 50

Configuring the Scanner

3–11

MSI Plessey Options The following options are available for MSI Plessey codes:

MSI Plessey Check Digit When enabled, the scanner verifies the one or two digit check character before transmitting the data. Check digits are not included in the transmitted data.

MSI Plessey 2 Check Digit Algorithm When enabled, the scanner performs an additional verification. You must select either Mod 10 - Mod 10 (Default) or Mod 11 - Mod 11 check digits.

Publication 2755-6.2

Page 51

3–12

Configuring the Scanner

I 2-of-5 and Discrete 2-of-5 Options The following options are available for Interleaved and Discrete 2 of 5 symbols:

I 2 of 5 (14 digit) to EAN 13 Conversion When enabled, 14 character Interleaved 2 of 5 data is converted and transmitted in an EAN 13 format. Note: Interleaved 2 of 5 must be enabled and one code length (Length 1 or Length 2) must be set to 14. In addition, the code must have a leading 0 and a valid EAN 13 check digit.

Code Lengths Specifies the expected length of the bar code symbol. When a specific length is enabled, symbols that are not the specified length are ignored. Only one or two lengths may be specified, all other lengths are ignored. First scan the length symbol followed by the 2 digit length. Length 1 may range from 01 to 31. Length 2 may be in the range of 00 to 31. Determine the number of characters in a symbol by counting the number of printed digits (human readable characters). Note: The scanner cannot be configured to read Interleaved or Discrete 2-of-5 labels of “any length”. You must specify code length(s).

Publication 2755-6.2

Page 52

Configuring the Scanner

3–13

Data Format Options The following options define the what happens to the data after a symbol has been decoded:

Data Prefix / Suffix To add prefix or suffix data to bar code data, scan the prefix or suffix bar code followed by the 4 digit ASCII equivalent value for each character (refer to Appendix D for the ASCII chart). Only one character may be specified as a suffix or prefix. When you enter the last digit of a prefix or suffix, the scanner lets you know that you have entered a valid value by providing a high-low-high beep.

Data Transmission Formats You can set whether or not prefix or suffix data is added to the decoded symbol data. You have four options:

• • • •

<DATA> only bar code data is sent <PREFIX> <DATA> prefix data is sent then the bar code data <DATA> <SUFFIX> bar code data is sent then the suffix data <PREFIX><DATA><SUFFIX> prefix data is sent then bar code data followed by the suffix data

Transmit NO READ Message When enabled, a NR is transmitted with each no-read. If enabled, a prefix and suffix will appear with the NR output message.

Publication 2755-6.2

Page 53

3–14

Configuring the Scanner

Transmit Code ID Character The code ID identifies a scanned bar code symbol’s code type. If enabled, the code ID is sent after the prefix and before the bar code data. The code ID codes are: A = UPC-A, UPC-E, or EAN 13 B = Code 39 C = Codabar D = Code 128 E = Code 93

F = Interleaved 2 of 5 G = Discrete 2 of 5 J = MSI Plessey K = EAN 128

Transmit AIM ID Character When enabled, the AIM code identifier is sent after the prefix and before the bar code data. The identifier is a three character prefix. Refer to the following: Each AIM Code Identifier contains the 3-character string ]cm where: ]

=

Flag Character (ASCII 93)

c

=

Code Character (see table below)

m

=

Modifier (see table on next pages)

Code Character / Generic Identifier

Code Type

A / ]A0

Code 39

C / ]C0

Code 128

E / ]E0

UPC/EAN

I / ]I0

Interleaved 2 of 5

Publication 2755-6.2

Page 54

Configuring the Scanner

3–15

The modifier character is the sum of the applicable option values based on the following table. Code Type

Code 39

Option Value

Option

0 1 2

No Check character or Full ASCII processing. Reader has checked one check character. Reader has stripped check character. Reader has performed Full ASCII character conversion. A Full ASCII bar code 1234 with check character W, A+I+MI+DW, can be transmitted as ]A71234 where 7 = (1+2+4). Standard data packet. No Function code 1 in first symbol position. Function code 1 in first symbol character position. Function code 1 in second symbol character position. A Code (EAN) 128 bar code 12345 with Function 1 character in the first position, Fcnt112345 will transmitted as ]C112345. Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data). Two digit supplement data only. Five digit supplement data only. EAN-8 data packet. A UPC-A bar code 012345678905 will be transmitted as ]E00012345678905. No check digit processing. Reader has checked check digit. Reader has stripped check digit before transmission.

4 Example: 0

Code 128

1 2 Example:

0

EAN/UPC

1 2 4 Example:

Interleaved 2 of 5

0 1 2 Example:

An I 2 of 5 bar code without check digit, 4123 will be transmitted as ]I04123.

Publication 2755-6.2

Page 55

3–16

Configuring the Scanner

According to AIM standards, a UPC with supplemental bar code is transmitted in one of the following formats: ]E0 (UPC chars) (terminator) ]E2 (supplemental) (terminator) or ]E2 (supplemental) (terminator) ]E0 (UPC chars) (terminator) In the 2755-HDG-4, however, this format is changed to: ]E0 (UPC chars) ]E2 (supplemental) Therefore, a UPC with two supplemental characters, 01234567890510, will be transmitted as a 21-character string ]E00012345678905]E110.

Publication 2755-6.2

Page 56

Configuring the Scanner

3–17

Laser Control and Audible Response Options Beep After Decode When enabled, the scanner will beep after a symbol has been decoded. We recommend that you leave this option enabled. Laser On Time Out This setting determines the maximum time the scanner remains on while the trigger is pressed. The time out is programmable in 0.5 second increments from 0.5 seconds to 5.0 seconds. Hands-Free Stand Operation Timeout If the scanner is used with an adjustable stand (Catalog No. 2755-HFN-K1, -K2), the scanner operates without pressing the trigger. Refer to Appendix C for hands-free operation. The timeout determines how long the scanner scans for a label before reducing the scan rate and beam intensity. The scanner will resume scanning at the normal rate when a label is presented. The timeout is selectable in 15 minute intervals between 15 and 90 minutes. Power Mode Determines whether or not the scanner power remains on after a decode attempt. With low power mode enabled, the scanner powers down after each attempted decode. With continuous power mode enabled, the scanner remains on at all times. We recommend that you use the following settings:

• low power mode for AdaptaScan Pass Through cable • continuous power mode for Synapse cables Note: When the scanner is in low power mode and a label is scanned, the first character of the first symbol will not be read as the scanner powers up. Use continuous mode if this causes a problem with your application (such as stand mode or A-B Basic Module applications). Publication 2755-6.2