The text of a manual · part 8 of 13
Bulletin 2755 Hand-Held Scanner with Wedge Option (Catalog No. 2755-G3-W, 2755-G6-W) User Manual: 7 - Symbologies
Pages 54 to 68 of 88, from Bulletin 2755 Hand-Held Scanner with Wedge Option (Catalog No. 2755-G3-W, 2755-G6-W) User Manual
The original document is the PDF (616 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-G3
Page 54
Chapter
7
A–B
Symbologies Chapter Objectives
This chapter shows how to enable bar code symbologies the scanner is capable of reading including:
• Code 39 • UPC-A and UPC-E (with optional 2 or 5-digit supplements)
• EAN-8 and EAN-13 (with optional 2 or 5-digit supplements)
• Interleaved 2 of 5 • Standard 2 of 5 • Code 128 • Codabar To disable or enable specific bar code symbologies, scan the appropriate bar code labels in each section. Note: We recommend that you disable all symbologies not used by your application. Throughout this chapter, the default symbology selections are flagged by an asterisk (*).
Label Lengths
The minimum label lengths are set to 1 character, except for Interleaved 2 of 5 which is set to 2 characters and Standard 2 of 5 which is set to 4 characters. The maximum label length for all symbologies is set to 32 characters. You can set minimum and maximum label lengths. Note: The minimum length must be less than or equal to the maximum length for scanning to occur.
7–1
Page 55
Chapter 7 Symbologies
Code 39
To disable Code 39, scan label OA.
OA
Disable Code 39
To enable Code 39, scan option OB or OC. After enabling Code 39, make any additional required selections from options OD through OI.
7–2
OB
Enable Standard Code 39 *
OC
Enable Full ASCII Code 39
Page 56
Chapter 7 Symbologies
Modulo 43 Check Character Options OD and OE allow you to enable or disable the Modulo 43 check character for Code 39. To enable the Modulo 43 check character, scan label OE. To disable the Modulo 43 check character, scan label OD.
OD
Disable Modulo 43 * Check Character
OE
Enable Modulo 43 Check Character
Transmit Start/Stop Characters You can transmit or suppress the Start and Stop characters in Code 39. To suppress transmission of the Start and Stop characters, scan label OF.
OF
Do Not Transmit * Start and Stop
To enable transmission of the Start and Stop characters, scan label OG.
OG
Transmit Start and Stop
7–3
Page 57
Chapter 7 Symbologies
Code 39 (continued)
Minimum Length The minimum length of Code 39 is set by scanning label OH and then two digits (01 - 32) in Appendix B.
OH
+ Minimum Length (Specified by two digits 01-32)
For example, to enter a minimum length of 05, scan the OH label, then scan codes 0 and 5 in Appendix B. Maximum Length The maximum length of Code 39 is set by scanning label OI and then two digits (01 - 32) in Appendix B.
OI
+ Maximum Length (Specified by two digits 01-32)
For example, to enter a maximum length of 05, scan the OI label, then scan codes 0 and 5 in Appendix B. If the minimum and maximum lengths are set equal, only codes of that exact length are read.
7–4
Page 58
Chapter 7 Symbologies
UPC (A and E)
To disable all UPC labels, scan label QA.
QA
Disable UPC (A and E)
Supplements Option QB or option QC enable both UPC-A and UPC-E. To enable scanning of UPC labels with the 2 or 5 Digit supplements, scan label QB.
QB
Enable UPC with 2 or 5 Digit Supplement Enabled
To enable scanning of UPC labels with the 2 or 5 Digit supplements disabled, scan label QC.
QC
Enable UPC * with 2 or 5 Digit Supplement Disabled
Expanded UPC-E You can enable/disable expansion of E labels to A labels. To disable expanded UPC-E, scan label QH.
QH
Disable * Expanded UPC-E
To enable expansion of E labels to A labels, scan label QI.
QI
Enable Expanded UPC-E
7–5
Page 59
Chapter 7 Symbologies
UPC (A and E) (continued)
Transmit Number System Digit You can enable or disable the transmission of the first character in a UPC symbol (the number system character). To disable transmission of the first character in a UPC symbol, scan label QD.
QD
Disable Transmission Number System Digit
To enable transmission of the first character in a UPC symbol (the number system character), scan label QE.
QE
Enable Transmission * Number System Digit
Transmit Check Digit You can enable or disable the transmission of the last character in a UPC symbol (the check digit). To disable transmission of the check digit in a UPC symbol, scan label QF.
QF
Disable Transmission of Check Digit
To enable transmission of the check digit in a UPC symbol, scan label QG.
QG
7–6
Enable Transmission of Check Digit *
Page 60
Chapter 7 Symbologies
UPC to EAN Translation You can cause UPC labels to be transmitted as EAN-13 labels. To enable UPC to EAN translation, scan label QJ.
QJ
Enable UPC to EAN Translation
To disable UPC to EAN translation, scan label QK.
QK
Disable UPC to EAN Translation *
7–7
Page 61
Chapter 7 Symbologies
EAN/JAN
Scan label RA to disable EAN/JAN (8 or 13 digit).
RA
Disable EAN/JAN * (8 or 13 digit)
Supplements Option RB or option RC enables both EAN 8-digit and EAN 13-digit. EAN/JAN labels can be read with or without supplements. To enable scanning of EAN/JAN labels with the 2 or 5 digit supplements, scan label RB.
RB
Enable EAN/JAN with 2 or 5 Digit Supplement Enabled
To enable scanning of EAN/JAN labels with the 2 or 5 Digit supplements disabled, scan label RC.
RC
7–8
Enable EAN/JAN with 2 or 5 Digit Supplement Disabled
Page 62
Chapter 7 Symbologies
Transmit Number System Digit You can enable or disable the transmission of the first character in an EAN/JAN symbol (the number system character). To disable transmission of the first character in an EAN/JAN symbol, scan label RD.
RD
Disable Transmission Number System Digit
To enable transmission of the first character in an EAN/JAN symbol, scan label RE.
RE
Enable Transmission * Number System Digit
Transmit Check Digit You can enable or disable the transmission of the last character in an EAN/JAN symbol (the check digit). To disable transmission of the check digit in an EAN/JAN symbol, scan label RF.
RF
Disable Transmission of Check Digit
To enable transmission of the check digit in an EAN/JAN symbol, scan label RG.
RG
Enable Transmission of Check Digit *
7–9
Page 63
Chapter 7 Symbologies
Interleaved 2 of 5
Scan label PA to disable Interleaved 2 of 5.
PA
Disable Interleaved 2 of 5 *
Check Digit You can enable Interleaved 2 of 5 with or without the check digit. To enable Interleaved 2 of 5 without the check digit, scan label PB.
PB
Enable Interleaved 2 of 5 without Check Digit
To enable Interleaved 2 of 5 with the check digit, scan label PC.
PC
7–10
Enable Interleaved 2 of 5 with Check Digit
Page 64
Chapter 7 Symbologies
Minimum Length To set a minimum length (other than two) for Interleaved 2 of 5, scan label PD and then two digits (02-32) in Appendix B. The value of the number you scan must be even. Odd numbers are ignored.
PD
+ Minimum Length (Specified by two digits 02-32)
For example, to enter a minimum length of 12, scan the PD label, then scan codes 1 and 2 in Appendix B. Maximum Length To set a maximum length for Interleaved 2 of 5, scan label PE and then two digits (02-32) in Appendix B. The value of the number you scan must be even.
PE
+ Maximum Length (Specified by two digits 02-32)
For example, to enter a maximum length of 12, scan the PE label, then scan codes 1 and 2 in Appendix B. If the minimum and maximum lengths are set equal, only codes of that exact length are read.
7–11
Page 65
Chapter 7 Symbologies
Standard 2 of 5
Scan label PF to disable Standard Code 2 of 5.
Disable * Standard 2 of 5
PF
To enable Standard Code 2 of 5, scan label PG.
Enable Standard 2 of 5
PG
Minimum Length To set a minimum length (other than 4) for Standard Code 2 of 5, scan label PH and then two digits (04-32) in Appendix B.
+
PH
Minimum Length (Specified by two digits 04–32)
Maximum Length To set a maximum length for Standard Code 2 of 5 messages, scan label PI and then two digits (04-32) in Appendix B.
PI
+ Maximum Length (Specified by two digits 04–32)
If the minimum and maximum lengths are set equal, only codes of that exact length are read. 7–12
Page 66
Chapter 7 Symbologies
Code 128
Scan label TA to disable Code 128.
TA
Disable Code 128
Scan option TB to enable Code 128.
TB
Enable Code 128 *
Minimum Length To set a minimum length for Code 128, scan label TC, then two digits (01-32) in Appendix B.
TC
+ Minimum Length (Specified by two digits 01-32)
Maximum Length To set a maximum length for Code 128, scan TD, then two digits (01-32) in Appendix B.
TD
+ Maximum Length (Specified by two digits 01-32)
If the minimum and maximum lengths are set equal, only codes of that exact length are read.
7–13
Page 67
Chapter 7 Symbologies
Codabar
Scan label VA to disable Codabar.
VA
Disable Codabar *
Scan option VB to enable Codabar.
VB
Enable Codabar
Transmit Start/Stop Characters You can enable or disable the transmission of the Start and Stop characters in Codabar. To disable transmission of the Start and Stop characters, scan label VC.
VC
Disable Transmission * Start/Stop Characters
To enable transmission of the Start and Stop characters, scan label VD.
VD
7–14
Enable Transmission Start/Stop Characters
Page 68
Chapter 7 Symbologies
Minimum Length To set a minimum length for Codabar messages, scan label VE and then two digits (01-32) in Appendix B.
VE
+ Minimum Length (Specified by two digits 01-32)
For example, to enter a minimum length of 05, scan the VE label, then scan codes 0 and 5 in Appendix B. Maximum Length To set a maximum length for Codabar messages, scan label VF, and then two digits (01-32) in Appendix B.
VF
+ Maximum Length (Specified by two digits 01-32)
For example, to enter a minimum length of 05, scan the VF label, then scan codes 0 and 5 in Appendix B. If the minimum and maximum lengths are set equal, only codes of that exact length are read.
7–15