Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 13

Bulletin 2755 Hand-Held Scanner with Wedge Option (Catalog No. 2755-G3-W, 2755-G6-W) User Manual, pages 75 to 79

Pages 75 to 79 of 88: D - Maintenance; E - Scanner Parameters

The original document is the PDF (616 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-G3

Page 75

Appendix

D

A–B

Maintenance This appendix provides general maintenance information for your scanner.

Cleaning Window

You may need to clean the window of the scanner. Carefully clean the window by first removing loose particles of dirt with clean air. Then use a soft, lint free cloth moistened with an optical quality cleaning fluid for plastic lenses and wipe the window in a single direction (don’t wipe cloth back and forth across window). Do not leave streaks. CAUTION:

!

Do not use abrasive material or solvents (e.g., alcohol or acetone) on the window. These items may damage the window or finish on the scanner.

WARNING:

! Inspecting Cables

The scanner has no serviceable parts. Do not open the housing of the scanner.

Periodically inspect the cable on the scanner for wear and other signs of damage. A worn or damaged cable may interfere with the operation of the scanner. Contact your Allen-Bradley representative to order replacement cables.

D–1

Page 76

Appendix

E

A–B

Scanner Parameters Each bar code label in this manual is preceded by two characters. The following tables list the two character mnemonic for each scanner parameter and the page location of the corresponding label. Mnemonic ZA ZB ZC @C @A @B AA AB AC AD BC BD NP NQ NO NN

General Scanner Setup Parameters Function Set Scanner to Factory Defaults Display Scanner Configuration Transmit Program Version Number Transmit Program ID Enable Full Continuous Power Enable Standby Power Beeper Off Beeper On; Volume Low Beeper On; Volume Medium Beeper On; Volume Loud Capture Count=1 Capture Count=2 Disable Spotter Beam Enable Spotter Beam Enable Autosense Mode Disable Autosense Mode

Page # 4-10 5-1 5-2 5-2 5-3 5-3 5-4 5-4 5-4 5-4 5-5 5-5 5-6 5-6 5-7 5-7

E–1

Page 77

Appendix E Scanner Commands

Mnemonic CE CF

CG

CH CI

Mnemonic IA IB IC MA MB MC MD ME MF JA JB FA FB KA KB LA LB GA GB

E–2

Wedge Parameters Function Enable Wedge Mode Terminal Type = PC-AT, PS/2 and 50/60/80, Allen-Bradley 6121, Allen-Bradley 1784-T50, -T60 Allen-Bradley 2706-DL40 Allen-Bradley 1784-T35 (AT mode) Compaq 386, 286 Terminal Type = PC-XT, Allen-Bradley 6120, 2706-DL40, Allen-Bradley 1784-T35 (XT mode) Compaq Deskpro Terminal Type = IBM 3151, 3472 Terminal Type = DEC VT220, VT240, VT320, VT340, VT420, VT1000

Message Format Parameters Function Prefix = None Prefix = STX Prefix = SOH Suffix=None Suffix = ETX Suffix = CR Suffix = LF Suffix = HT Suffix = CR and LF Disable Scanner Identifier Enable Scanner Identifier Disable Code Identifier Enable Code Identifier Preamble = None Preamble = 4 ASCII Characters Postamble = None Postamble = 4 ASCII Characters No Intercharacter Delay Set Intercharacter Delay

Page # 4-6 4-6

4-6

4-7 4-7

Page # 6-2 6-2 6-2 6-3 6-3 6-3 6-3 6-3 6-3 6-4 6-4 6-5 6-5 6-7 6-7 6-7 6-7 6-10 6-10

Page 78

Appendix E Scanner Commands

Mnemonic OA OB OC OD OE OF OG OH OI QA QB QC QD QE QF QG QH QI QJ QK RA RB RC RD RE RF RG PA PB PC PD PE

Symbology Parameters Function Disable Code 39 Enable Standard Code 39 Enable Full ASCII Code 39 Disable Modulo 43 Check Character Enable Modulo 43 Check Character Do Not Transmit Code 39 Start/Stop Characters Transmit Code 39 Start/Stop Characters Set Minimum Length for Code 39 Labels Set Maximum Length for Code 39 Labels Disable UPC (A and E) Enable UPC (A and E) with 2 or 5 Digit Supplements Enable UPC (A and E) without 2 or 5 Digit Supplements Disable Transmission UPC Number System Digit Enable Transmission UPC Number System Digit Disable Transmission UPC Check Digit Enable Transmission UPC Check Digit Disable Expanded UPC-E Enable Expanded UPC-E Enable UPC to EAN Translation Disable UPC to EAN Translation Disable EAN/JAN (8 or 13) Enable EAN/JAN with 2 or 5 Digit Supplements Disable EAN/JAN without 2 or 5 Digit Supplements Disable Transmission EAN/JAN Number System Digit Enable Transmission EAN/JAN Number System Digit Disable Transmission EAN/JAN Check Digit Enable Transmission EAN/JAN Check Digit Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 without Check Digit Enable Interleaved 2 of 5 with Check Digit Set Minimum Length for Interleaved 2 of 5 Labels Set Maximum Length for Interleaved 2 of 5 Labels

Page # 7-2 7-2 7-2 7-3 7-3 7-3 7-3 7-4 7-4 7-5 7-5 7-5 7-6 7-6 7-6 7-6 7-5 7-5 7-7 7-7 7-8 7-8 7-8 7-9 7-9 7-9 7-9 7-10 7-10 7-10 7-11 7-11

E–3

Page 79

Appendix E Scanner Commands

Mnemonic PF PG PH PI TA TB TC TD VA VB VC VD VE VF

E–4

Symbology Parameters (continued) Function Disable Standard 2 of 5 Enable Standard 2 of 5 Set Minimum Length for Standard 2 of 5 Labels Set Maximum Length for Standard 2 of 5 Labels Disable Code 128 Enable Code 128 Set Minimum Length for Code 128 Labels Set Maximum Length for Code 128 Labels Disable Codabar Enable Codabar Disable Transmission Codabar Start/Stop Characters Enable Transmission Codabar Start/Stop Characters Set Minimum Length for Codabar Labels Set Maximum Length for Codabar Labels

Page # 7-12 7-12 7-12 7-12 7-13 7-13 7-13 7-13 7-14 7-14 7-14 7-14 7-15 7-15