The text of a manual · part 4 of 18
Multi-Purpose Bar Code Workstation Series B (Catalog Number 2755-DH1) User Manual: 4 - Installation
Pages 21 to 25 of 132, from Multi-Purpose Bar Code Workstation Series B (Catalog Number 2755-DH1) User Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-DH1
Page 21
Chapter
A–B
4
Installation Chapter Objectives
Carefully read this chapter before installing the decoder. We will present recommendations and procedures for installing the decoder.
Attention
! !
Electrical Precautions
ATTENTION: Do not make adjustments to the decoder. Only use procedures specified in this manual.
ATTENTION: No user maintenance of the decoder is required. Do not open the enclosure!
Install this equipment using publication NFPA 70E, Electrical Safety Requirements for Employee Workplaces. We have set up a few specific guidelines for you to follow in addition to the general guidelines of NFPA 70E. With solid-state systems, grounding helps to limit the effects of noise due to electromagnetic interference (EMI). To avoid problems caused by EMI, shielded cables should be used.
Grounding Recommendations
Grounding is an important safety measure in electricalinstallations. With solid-state systems, grounding also helps limit the effects of noise due to electromagnetic interference (EMI). An authoritative source on grounding requirements is the National Electrical Code published by the National Fire Protection Association of Boston, Massachusetts. Article 250 of the Code discusses the types and sizes of wire conductors and safe methods of grounding electrical equipment and components.
4–1
Page 22
Chapter 2 Description of Hardware
How to Connect Your Equipment Connect your equipment as shown in Figure 4.1. A step-by-step procedure follows. Figure 4.1 Connecting the Decoder to a Host Computer and Display Terminal
Step 1
Step 2
Step 5 (optional)
0
I
Display Host
Step 4
Step 3
4–2
Page 23
Chapter 4 Installation
For your convenience, mounting flanges are built into the unit. The decoder can be either table or wall mounted The mounting dimensions are shown in Figure 4.2. Figure 4.2 Mounting Dimensions
71/2” 6 5/8”
73/8” 8”
Step 1. Connect your scanning device to the 9-pin connector labeled Scanner. Step 2. Connect the host computer to the 25-pin connector labeled Host Computer, shown in Chapter 3. Step 3. Set the Host’s communication parameters to match those of the decoder. Step 4. (Optional) Connect a display terminal to the 25-pin connector labeled Display Terminal shown in Chapter 3. Set the display terminal’s baud rate, parity and other communication parameters to match those of the decoder and the host computer. Step 5. Connect the decoder to the power source using the supplied cable. Step 6. (Optional) Connect your external speaker, or headphones, to the external speaker jack. Adjust the volume and tone to a comfortable level. 4–3
Page 24
Chapter 2 Description of Hardware
Incoming Power Cable
The incoming power connector is a standard IEC 320. This connector is widely used on computing equipment and instrumentation. Replacement cables are readily available in different lengths. Figure 4.3 shows the polarization of the connector. Figure 4.3 Polarization of the Power Connector
0
I
Ground
Neutral Line
Power Up Sequence
When the decoder is turned ON, the following sequence will occur: 1. The green LED labeled Power will light and remain lit. 2. The decoder resets, ROM/RAM tests are performed, and the decoder is configured according to the contents stored in EEPROM. If any of the following messages appear on the connected display terminal, return your decoder for repair: EEPROM Self Test Failed ROM Self Test Failed RAM Self Test Failed 3. When all tests are passed, a. The green LED labeled Valid Read will flash once. b. A single tone will be emitted from the decoder. If the Laser Connection Detection function is enabled and: A laser scanner is detected a. The laser scanner will briefly flash
4–4
Page 25
Chapter 4 Installation b. The red LED labeled Laser ON will flash once c. A high pitched series of tones will be produced A wand is detected a. A series of low pitched tones will be produced Note: When using a hand-held laser scanner or Catalog No. 2755-L2 scan head, do not trigger either device during power up. If you hold the trigger, the decoder will act as if a wand is connected. The decoder will not recognize any laser scanners until it is reset by an escape sequence or by turning the decoder OFF and then ON.
4–5