Page 14

Chapter

A–B

3

Host Computers and Display Terminals Chapter Objectives

This chapter discusses communications between a decoder, host computer, and display terminal.

Communications Ports

The decoder has two independent communications ports, the Host Computer port and Display Terminal port. The Host Computer port supports both RS-232-C and RS-422 communications. The Display Terminal port only supports RS-232-C. All communication parameters, such as baud rate, parity, stop bits, etc. are common to both ports. The Host Computer port is used by the:

• Decoder to send decoded bar code data to the host for processing • Host computer to display the configuration screen • Host computer to send messages to the display terminal • Host computer to download commands (escape sequences) to the decoder. These commands customize the operating parameters. The Display Terminal port provides a convenient connection point for a local terminal or serial printer. If the bar code symbol is illegible, the terminal can be used to manually enter and transmit bar code data to the host. You cannot enter data into this port when the decoder is scanning. A display terminal can receive decoded bar code data:

• Directly from the decoder • As an echo from the host The Display Terminal port can be enabled or disabled, as described on pages 3-2 and 3-3.

3–1

Page 15

Chapter 3 Host Computers and Display Terminals

Display Terminal Port Disabled

The decoder’s ability to transmit decoded bar code data to a display terminal can be enabled or disabled. If your host computer echoes all received data, you should disable the Display Terminal port using the Disable Terminal Port configuration bar code symbol. If you do not disable the Display Terminal port you will receive duplicate messages, one from the host and the other from the decoder. This function’s default setting is Display Terminal Port Enabled. When the decoder decodes a bar code symbol, it will transmit the decoded data to the host. When the host receives the data, it may echo the data through the decoder’s Display Terminal port, to the attached display terminal. Refer to Figure 3.1. Figure 3.1 Display Terminal Port Disabled Decoder

Decoded Bar code data Echo of decoded Bar code data Echo of decoded Bar code data Configuration Commands

Bar code data entered on keyboard

Display Terminal

Host Computer Transmit

Receive

Host

Decoder and Display Terminal

Display Terminal

Host

Decoder

Host

Use this mode if your host computer does echo all data transmissions to local terminals.

Note: With the Display Terminal port disabled, all escape sequences sent to the decoder will also be sent to any local terminal connected to the decoder. Make sure these escape sequences will not affect your terminal’s operation. Note: If the decoder receives a Show Configuration command, the configuration display screen will be sent only to the Host Computer port. 3–2

Page 16

Chapter 3 Host Computers and Display Terminals

Display Terminal Port Enabled

The decoder’s ability to transmit decoded bar code data to a display terminal can be enabled or disabled. If your host computer does not echo data, you can enable the Display Terminal port using the Enable Terminal Port configuration bar code symbol. When the decoder decodes a bar code symbol, it will be transmitted simultaneously to the Host Computer and Display Terminal ports. Refer to Figure 3.2. Figure 3.2 Display Terminal Port Enabled Decoder

Decoded Bar code data

Decoded Bar code data

Configuration Commands

Bar code data entered on keyboard

Display Terminal

Host Computer Transmits

Receives

Host

Decoder

Display Terminal

Host

Decoder

Host and Display Terminal

Use this mode if your host computer does not echo data transmissions to local terminals.

Note: If the decoder receives a Show Configuration command, the configuration display screen will be sent to the host and local display terminal simultaneously.

3–3

Page 17

Chapter 3 Host Computers and Display Terminals

Host Computer Port Pinout

The Host Computer port is configured as a Data Terminal Equipment (DTE) device. Table 3.A defines which pins of the 25 pin (female) D-shell connector are used to provide RS-232-C and RS-422 communications.

Pin

Function

Abb.

What This Pin Does

1

Protective Ground

GND

Electrically bonded to the chassis and to the metal shell of the 25-pin connector. When plastic shell (non-shielded) connectors are used on the communications cable, the cable shield drain wire should be connected to this pin.

2

RS-232-C Transmitted Data (Output)

TxD

Serial output from the decoder.

3

RS-232-C Received Data (Input)

RxD

Serial input data from the host computer. Escape sequence commands for programming and control are sent to this pin.

4

RS-232-C Request To Send

RTS

Indicates to the host computer that the decoder is on-line. When RTS/CTS handshaking is enabled, RTS will go high when the terminal or decoder wishes to transmit.

5

RS-232-C Clear To Send

CTS

The CTS input must be driven greater than +3 VDC or left unconnected to allow the decoder to output decoded label information. When CTS is less than -3 VDC, transmission from the decoder will cease within 1-character transmission time. When the host is receiving input from the local display terminal, CTS is driven low.

6

RS-232-C Data Set Ready

DSR

Internally connected to Pin 20 to provide loopback of DTR signal.

7

Signal Common

COM

This is the signal reference common which must be connected to signal common on the host computer. Pins 1, 7, and 25 are tied together in the decoder and tied to chassis ground.

14

RS-422 Transmitted Data (output)

TxB+

This RS-422 line is used to send data from the decoder to the host.

15

RS-422 Transmitted Data (output)

TxA-

This RS-422 line is used to send data from the decoder to the host.

16

RS-422 Receive Data (input)

RxA’-

This RS-422 line is used to receive data from the host.

17

RS-422 Receive Data (input)

RxB’+

This RS-422 line is used to receive data from the host.

20

RS-232-C Data Terminal Ready

DTR

Internally connected to pin 6 to provide loopback of DSR Signal.

25

Signal Common

COM

See comments for Pin 7.

Note: When RTS/CTS Handshaking is enabled, both the Host and Display Terminal ports must either support the RTS/CTS Handshaking protocol, or the Display Terminal port’s RTS/CTS lines must be unconnected.

3–4

Page 18

Chapter 3 Host Computers and Display Terminals

RS-232-C Host Computer Interface

Figure 3.3 shows how to connect the decoder to your host computer using RS-232-C. We recommend using Belden (or equivalent) type 9363, 9533, 9535, or 9537 cable. Figure 3.3 Connecting A Host Computer Via RS-232-C Host Computer Port on decoder① Shield②

Host RS-232-C Port

GND

1

RS-232-C TxD③

2

RxD

RS-232-C RxD③

3

TxD

RS-232-C RTS

4

CTS

RS-232-C CTS

5

RTS

RS-232-C DSR

6

DTR

COM③

7

COM

RS-232-C DTR 20

DSR

COM 25

① DTE = Data Terminal Equipment ② When non-metallic connector shells are used. (If cable has a metal connector shell, connect shield to the shell.) ③ Pins 2, 3 and 7 are the minimum connections that can be used. All unused pins should be left open.

When the host computer wishes to receive data from the local display terminal, it must set Pin 5 (CTS) on the host computer port to OFF (less than -3 V). This prevents the decoder from transmitting and insures a clear channel for communications between the host computer and the local display terminal. If the decoder receives data from a scanning device, it will force RTS low preventing communications between the host and display terminal.

3–5

Page 19

Chapter 3 Host Computers and Display Terminals

RS-422 Host Computer Interface Figure 3.4 shows how to connect the decoder to your host computer using RS-422. We recommend using Belden (or equivalent) type 9512 cable. Figure 3.4 Connecting A Host Computer Via RS-422 Host Computer Port on Decoder

Host RS-422 Port

Shield① GND 1 RS-422 TxB+ 14

RxB’+

RS-422 TxA- 15

RxA’+

RS-422 RxA’- 16

TxA-

RS-422 RxB’+ 17

TxB+

COM 7

COM

COM 25 ① When non-metallic connector shells are used. (If cable has a metal connector shell, connect shield to the shell.)

Display erminal Port Pinout

The Display Terminal port is configured as Data Communication Equipment (DCE). Table 3.B defines which pins of the 25-pin (female) D-shell connector are used.

Pin

Function

Abb.

Additional Information

1

Protective Ground

GND

This pin is electrically bonded to the chassis and to the metal shell of the 25-pin connector. When plastic shell (non-shielded) connectors are used on the communications cable, the cable shield drain wire should be connected to this pin.

2

Received Data

RxD

Serial input data from the display terminal is received on this pin.

3

Transmitted Data

TxD

Serial output data from the decoder is passed to the display terminal on this pin.

4

Request To Send

RTS

RTS is an input to the decoder. It may be used to notify the host of a forthcoming transmission.

5

Clear To Send

CTS

CTS is an output from the decoder. It is driven to less than -3 VDC whenever the decoder transmits.

7

Signal Common

COM

This must be connected to signal common on the display terminal, Pins 1, 7, and 25 are tied together in the decoder.

25

Signal Common

COM

See comments for Pin 7.

3–6

Page 20

Chapter 3 Host Computers and Display Terminals

RS-232-C Display Terminal Port Interface

Figure 3.5 shows how to connect the decoder to the display terminal. RS-232-C is the only supported interface for display terminals. We recommend using Belden (or equivalent) type 9363, 9533, or 9535 cable. Figure 3.5 Connecting the Display Terminal Via RS-232-C Decoder’s Display Terminal port DCE ②

Display Terminal

Shield① RS-232-C GND 1 RS-232-C RxD 2

TxD

RS-232-C TxD 3

RxD

RS-232-C RTS 4

CTS

RS-232-C CTS 5

RTS

COM 7

COM

COM 25

①

When non-metallic connector shells are used. (If cable has a metal connector shell, connect shield to the shell.)

②

DCE = Data Communication Equipment

3–7