Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 16 of 18

Multi-Purpose Bar Code Workstation Series B (Catalog Number 2755-DH1) User Manual, pages 112 to 114

Pages 112 to 114 of 132: A - Default Settings; B - Escape Sequence Summary

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-DH1

Page 112

Appendix

A–B

A

Default Settings Default Settings

The decoder has a set of default conditions. These conditions may be restored by scanning the Default Configuration, configuration bar code symbol. The details of the default configuration are as follows: Default

Bar Code Symbol

Enter Configuration Mode

–

•

Show Configuration

–

•

Exit Configuration Mode

–

•

Function

Disable Decoding

Escape Sequence

•

•

Disabled –

•

Default Configuration

Factory Set

•

Store Configuration

–

ROM/RAM Self Test

Enabled

Auto

•

Code Selection

All Codes

•

•

Check Character Verification (Code 39, I 2 of 5)

Disabled

•

•

1

•

•

Check Character Transmission (Code 39, I 2 of 5)

Disabled

•

•

Minimum and Maximum Length Checking (Code 39, Codabar, Code 128, Code 11)

1, 32

•

•

Minimum and Maximum Length Checking (I 2 of 5)

4, 32

•

•

UPC/EAN Options

Disabled

•

•

Codabar Start/Stop Character Transmission

Enabled

•

•

Code 39 Full ASCII Conversion

Disabled

•

•

Code ID Character Assignment

Code 39 a I 2 of 5b UPC/EAN c Codabar d Code 128 e Code 11 f

•

•

Code ID Character Transmission

Disabled

•

•

Reset

Check Characters (Code 11)

Tab

•

Getting Started

•

Code Selection

A–1

Page 113

Appendix A Default Settings

Default

Bar Code Symbol

Escape Sequence

Serial Port Configuration

9600 Baud 1 Stop bit 0’s parity

•

•

RTS/CTS Handshaking

Enabled

•

Intercharacter Delay Enable

Disabled

•

•

Intercharacter Delay Time

20 ms

•

•

XON/XOFF Pacing

Disabled

•

•

Single Read Mode

Disabled

•

•

Enable Next Read

–

•

•

Display Terminal Port

Enabled

•

Fixed Serial Port Configuration At Reset

Disabled

•

RTS/CTS

Enabled

•

Header

Empty

•

•

Trailer

CR LF

•

•

No – Read Recognition

Disabled

•

•

No – Read Message

Empty

•

•

Reader Address

Empty

•

•

System Serial Number

00000000

•

Good Read Beep Tone

12

•

•

Medium

•

•

On

•

•

Function

Speaker Volume Speaker /LED Control

Serial Port Configuration

Message Supplements

Speaker/LED

•

Pulse Speaker

Enabled

Laser Shutoff Delay

3 seconds

•

•

Laser Redundancy Check

Disabled

•

•

Laser Connection Detection

Disabled

•

•

Continuous Read Mode

Disabled

•

•

Trigger Latch Mode

Enabled

•

•

A–2

Tab

Laser Scanning Options

Page 114

Appendix

A–B

B

Escape Sequence Summary Escape Sequence

Function

Values of <n>

Default

Page No

Esc - y <n> A

Reader Address

0-1

Empty

5-37

Esc - y <n> B

Good Read Beep Tone

0 - 16

12

5-38

Esc - y <n> C

Speaker /LED Control

33, 34, 36, 38, 40

36

5-39

Esc - y <n> D

Intercharacter Delay Time

0 - 250

0

5-29

Esc - y <n> F

Code Selection

0 - 63

63

5-13

Esc - y <n> G

Check Characters

0 - 3, 8 - 11, 16 - 19, 24 -27

0

5-14

Esc - y <n> H

UPC/EAN/Codabar / Code 39 Options

0-127

0

5-20

Esc - y <n> I

Code ID Character Assignment

1-6

-

5-24

Esc - y <n> J

Single Read Mode

0-1

0

5-31

Esc - y <n> K

Enable Next Read

1

-

5-32

Esc - y <n> M

I 2-of-5 Length Checking Options

0 - 33

0

5-18

Esc - y <n> N

Header

0 - 10

Empty

5-33

Esc - y <n> O

Trailer

0 - 10

Empty

5-34

Esc - y <n> P

Serial Port Configuration

2 - 127

6

5-26

Esc - y <n> Q

Self Test Code ID Character TX No-Read Recognition

0 - 3, 16 - 19

16

5-12 5-25 5-35

Esc - y <n> R

Laser Scanning Options

0 - 15

8

5-41

Esc - y <n> S

Show Configuration

4

-

5-7

Esc - y <n> T

Pulse Speaker

1 - 16

-

5-40

Esc - y <n> U

Minimum and Maximum Length Checking

1-6

-

5-17

Esc - y <n> V

Laser Shut Off Delay

0 - 100

30

5-45

Esc - y <n> W

Disable Decoding

0-1

1

5-9

Esc - y <n> X

XON / XOFF

0-1

0

5-30

Esc - y <n> Y

No Read Message

0 - 10

0

5-36

Esc - y <n> Z

Reset/Store Configuration

1 or 5

-

5-10

B–1