The text of a manual · part 16 of 18
Multi-Purpose Bar Code Workstation Series B (Catalog Number 2755-DH1) User Manual, pages 112 to 114
Pages 112 to 114 of 132: A - Default Settings; B - Escape Sequence Summary
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-DH1
Page 112
Appendix
A–B
A
Default Settings Default Settings
The decoder has a set of default conditions. These conditions may be restored by scanning the Default Configuration, configuration bar code symbol. The details of the default configuration are as follows: Default
Bar Code Symbol
Enter Configuration Mode
–
•
Show Configuration
–
•
Exit Configuration Mode
–
•
Function
Disable Decoding
Escape Sequence
•
•
Disabled –
•
Default Configuration
Factory Set
•
Store Configuration
–
ROM/RAM Self Test
Enabled
Auto
•
Code Selection
All Codes
•
•
Check Character Verification (Code 39, I 2 of 5)
Disabled
•
•
1
•
•
Check Character Transmission (Code 39, I 2 of 5)
Disabled
•
•
Minimum and Maximum Length Checking (Code 39, Codabar, Code 128, Code 11)
1, 32
•
•
Minimum and Maximum Length Checking (I 2 of 5)
4, 32
•
•
UPC/EAN Options
Disabled
•
•
Codabar Start/Stop Character Transmission
Enabled
•
•
Code 39 Full ASCII Conversion
Disabled
•
•
Code ID Character Assignment
Code 39 a I 2 of 5b UPC/EAN c Codabar d Code 128 e Code 11 f
•
•
Code ID Character Transmission
Disabled
•
•
Reset
Check Characters (Code 11)
Tab
•
Getting Started
•
Code Selection
A–1
Page 113
Appendix A Default Settings
Default
Bar Code Symbol
Escape Sequence
Serial Port Configuration
9600 Baud 1 Stop bit 0’s parity
•
•
RTS/CTS Handshaking
Enabled
•
Intercharacter Delay Enable
Disabled
•
•
Intercharacter Delay Time
20 ms
•
•
XON/XOFF Pacing
Disabled
•
•
Single Read Mode
Disabled
•
•
Enable Next Read
–
•
•
Display Terminal Port
Enabled
•
Fixed Serial Port Configuration At Reset
Disabled
•
RTS/CTS
Enabled
•
Header
Empty
•
•
Trailer
CR LF
•
•
No – Read Recognition
Disabled
•
•
No – Read Message
Empty
•
•
Reader Address
Empty
•
•
System Serial Number
00000000
•
Good Read Beep Tone
12
•
•
Medium
•
•
On
•
•
Function
Speaker Volume Speaker /LED Control
Serial Port Configuration
Message Supplements
Speaker/LED
•
Pulse Speaker
Enabled
Laser Shutoff Delay
3 seconds
•
•
Laser Redundancy Check
Disabled
•
•
Laser Connection Detection
Disabled
•
•
Continuous Read Mode
Disabled
•
•
Trigger Latch Mode
Enabled
•
•
A–2
Tab
Laser Scanning Options
Page 114
Appendix
A–B
B
Escape Sequence Summary Escape Sequence
Function
Values of <n>
Default
Page No
Esc - y <n> A
Reader Address
0-1
Empty
5-37
Esc - y <n> B
Good Read Beep Tone
0 - 16
12
5-38
Esc - y <n> C
Speaker /LED Control
33, 34, 36, 38, 40
36
5-39
Esc - y <n> D
Intercharacter Delay Time
0 - 250
0
5-29
Esc - y <n> F
Code Selection
0 - 63
63
5-13
Esc - y <n> G
Check Characters
0 - 3, 8 - 11, 16 - 19, 24 -27
0
5-14
Esc - y <n> H
UPC/EAN/Codabar / Code 39 Options
0-127
0
5-20
Esc - y <n> I
Code ID Character Assignment
1-6
-
5-24
Esc - y <n> J
Single Read Mode
0-1
0
5-31
Esc - y <n> K
Enable Next Read
1
-
5-32
Esc - y <n> M
I 2-of-5 Length Checking Options
0 - 33
0
5-18
Esc - y <n> N
Header
0 - 10
Empty
5-33
Esc - y <n> O
Trailer
0 - 10
Empty
5-34
Esc - y <n> P
Serial Port Configuration
2 - 127
6
5-26
Esc - y <n> Q
Self Test Code ID Character TX No-Read Recognition
0 - 3, 16 - 19
16
5-12 5-25 5-35
Esc - y <n> R
Laser Scanning Options
0 - 15
8
5-41
Esc - y <n> S
Show Configuration
4
-
5-7
Esc - y <n> T
Pulse Speaker
1 - 16
-
5-40
Esc - y <n> U
Minimum and Maximum Length Checking
1-6
-
5-17
Esc - y <n> V
Laser Shut Off Delay
0 - 100
30
5-45
Esc - y <n> W
Disable Decoding
0-1
1
5-9
Esc - y <n> X
XON / XOFF
0-1
0
5-30
Esc - y <n> Y
No Read Message
0 - 10
0
5-36
Esc - y <n> Z
Reset/Store Configuration
1 or 5
-
5-10
B–1