Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 18

Multi-Purpose Bar Code Workstation Series B (Catalog Number 2755-DH1) User Manual, pages 108 to 111

Pages 108 to 111 of 132: 8 - Maintenance and Troubleshooting; 9 - Specifications

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-DH1

Page 108

Chapter

A–B

8

Maintenance and Troubleshooting Chapter Objectives

Troubleshooting guidelines are presented in this chapter.

Maintaining the Equipment

! Replacing the Fuse

ATTENTION: No user maintenance of the decoder is required. Do not open the enclosure!

Follow these steps to replace the decoder’s fuse. Step 1. Turn the decoder OFF. Step 2. Remove power cable from decoder to gain access to fuse housing. Step 3. Remove the fuse housing from its enclosure with a small flat–head screwdriver. Step 4. Lift black prong of the housing and at the same time slide metal fuse holder out of black plastic jacket. Step 5. Replace the blown fuse with a 1/4x 1 1/4 inch or 5 x 20 mm, 1 amp, time delay fuse.

Communications

Upon sending the escape sequence Esc – y <n> P, the new configuration of the serial port is immediately effective. Your host must be able to switch communications parameters to maintain communications. If you have problems communicating with the decoder, scan the Fixed Serial Port At Reset symbol. The decoder will be returned to its default configuration of: Baud Rate

9600

Parity

0

Stop Bits

1

For more information on serial port configurations, refer to Chapters 5 and 6, under the tab Serial Port Configuration. 8–1

Page 109

Chapter 8 Maintenance and Troubleshooting

Troubleshooting the System Problem

POWER ON indicator does not light.

Probable Cause Decoder is not turned ON.

Turn decoder ON. Switch is on rear of unit.

Improper connection to power supply.

Reconnect power cable to source and decoder. If cable is defective, replace it.

Fuse is blown.

Replace fuse.

No incoming power.

Check that voltage is present at service outlet.

POWER ON indicator Scanner is improperly connected is lit, but laser scanner or wand does not Scanner’s cable is damaged operate

No laser beam emitted from window of laser scanner.

8–2

Check cable and connection. Replace wand or laser scanner.

Disable Decoding command sent from host

Send Enable Decoding command from host.

Timeout for laser scanner is set to 0

Change timeout value to 120 using Esc – y 120 V.

Decoder is in single read mode and is awaiting Enable Next Read command.

Send Enable Next Read command.

RTS/CTS Handshaking configuration is incompatible between Decoder and host.

Check host computer’s protocol setup.

Scanner or Scanner’s cable is defective.

Replace scanner cable, replace scanner.

Poor quality labels.

Check that labels are good quality and within specifications.

Decoder is not set up correctly.

Make sure you programmed the decoder to match your application. Check: • Check character verification • Code type. • Length of code. • Minimum number of reads required for a valid read.

Loose cables or connections.

Check cables and connections.

Improper wand technique.

Make sure you are holding wand correctly

Communications parameters are incompatible.

Verify decoder, host, and display terminal communications parameters.

Improperly fabricated cable.

Refabricate or replace cable.

Improperly connected cable.

Check that the communication cable is securely connected.

Host port CTS is driven OFF.

Disconnect CTS or Drive CTS ON

Unable to read a label

No communication with host computer or display terminal

Possible Solution

Page 110

Chapter

A–B

9

Specifications

Mult-Purpose Bar Code Workstation (Catalog Number 2755-DH1)

Electrical Input Line Voltage:

90 – 264 VAC, 50/60 Hz.

Operating Current

0.5 Amp, max.

Power Consumption

40 VA, max.

Speaker Impedance

8 – 32 Ohms (tip positive)

Mechanical Enclosure

Heavy gauge steel, NEMA 1

LED Indicators

• • • • •

Weight

4 lbs. 4 oz. (2.0 kg).

Dimensions

8”L x 8”W x 2–1/4”H (20.3 x 20.3 x 5.7 cm).

Power Laser On Valid Read Transmit Receive

Environmental Operating Temp.

0° to 40°C (32° to 104°F)

Storage Temp.

–40° to 85°C (–40° to 185°F)

Relative Humidity

95%, noncondensing.

Vibration

2.5 Gs, 5 – 2000 Hz, 3 axis, operating or 5 Gs nonoperating

Shock

30 Gs, max., operating 50 Gs nonoperating

Regulation Compliance

Designed to meet UL and CSA requirements

Decoding Capabilities Autodiscriminating

Yes

Code Types

• • • •

Code 39 Extended Code 39 (full ASCII) Interleaved 2 of 5 UPC–A, UPC–E, EAN–13, EAN–8 (with 2– and 5– character supplements). • Codabar • Code 128 • Code 11 9–1

Page 111

Chapter 9 Specifications

Communications Stop bits Data bits

1 or 2 7

Parity

• • • •

0’s (space) 1’s (mark) even odd

Baud Rate

• • • • • •

600 1200 2400 4800 9600 19.2 K

Electrical Standard Host Computer Port Display Terminal Port

9–2

RS–232–C or RS–422 RS–232–C