Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 18

Multi-Purpose Bar Code Workstation Series B (Catalog Number 2755-DH1) User Manual: 6 - Programming Via Configuration Bar Code Symbols, pages 78 to 86

Pages 78 to 86 of 132, from Multi-Purpose Bar Code Workstation Series B (Catalog Number 2755-DH1) User Manual

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-DH1

Page 78

Chapter 6 Programming Via Configuration Bar Code Symbols

XON/XOFF Pacing

Enter

Whenever this pacing protocol is enabled, the decoder will stop transmission of data to the host whenever it receives an XOFF character. Transmission will resume after reception of an XON character. When pacing is disabled, the decoder will ignore these characters.

XON/XOFF

*Default is XON/XOFF Disabled. Exit

Single Read Mode In this mode, a single bar code symbol may be read only after an Enable Next Read command has been received by the decoder. This allows the software in the host computer to control when bar code data is entered into the system. When single read mode is enabled, bar code symbols will not be decoded until the Enable Next Read escape sequence is sent from the host to the decoder. The Enable Next Read command can be found on page 5–32 *Default is Single Read Mode Disabled. Note: These symbols should only be used in conjunction with host programming.

Enter

Single Read Mode

Exit

Display Terminal Port Scan these symbols to enable and disable bar code data from being transmitted to the display terminal in case the host echoes data to the terminal. For More information on the Display Terminal port, refer to Chapter 3, Host Computers and Display Terminals. *Default is Terminal Port enabled.

Enter

Enable/Disable Terminal Port

Exit

6–19

Page 79

Chapter 6 Programming Via Configuration Bar Code Symbols

Header The header is a group of characters transmitted before any bar code data. The number of characters can vary from 0 to 10.

Enter

Message

The default header is none (empty buffer). Characters from

Trailer The trailer is a group of characters transmitted after the bar code data. The number of characters can vary from 0 to 10. The default trailer is Cr Lf shown on the Configuration Display Screen as ^M^J.

Reader Address The reader address is a unique, one character address that you assign to the decoder. The address can be any one of 128 ASCII characters. The default reader address is none (empty buffer).

6–20

Character Menu

End Of Characters

Exit

Page 80

Chapter 6 Programming Via Configuration Bar Code Symbols

Enter

No–Read Message ON

No–Read Recognition

Message =

If no–read recognition is enabled and a bar code symbol was scanned but not decoded, the no–read message is transmitted, the Valid Read LED and speaker will be pulsed twice.

Characters from

The number of characters can vary from 0 to 10. * Default is No–Read Recognition OFF. The default no–read message is none (empty buffer).

End Of Characters

Character Menu

Exit

Enter

Serial Number A unique serial number, up to 10 digits, can be stored in each decoder. Serial numbers can consist of numbers, characters, or any combination of the two. Numbers and characters must be scanned from the character menu. The default serial number is 00000000.

Transmit or Serial Number =

Character from Character Menu

End Of Characters

Exit

6–21

Page 81

Chapter 6 Programming Via Configuration Bar Code Symbols

Speaker/LED Control When this feature is enabled, the Configuration Display Screen will show LED control and good read beep configuration information. Good reads will produce LED activity or a beep. Scans of the configuration bar code symbols will produce beeps and flashes. *Default is Speaker/LED Enabled. Enter

Speaker/LED Control

Exit

Good Read Beep The good read beep sounds upon a successful completion of a decode. Setting the tone to zero will disable the beep. As shown in the scale, 1 through 12 form a rough chromatic scale. * Default tone is 12,

Tone

Frequency

0 1 2 3 4 5 6 7 8 9 10 11 12* 13 14 15 16

No Beep 516 539 580 612 648 687 724 767 812 859 914 967 1037 1827 2398 3032

Speaker Volume Speaker volume can be set to one of four volumes. * Default volume is Medium.

6–22

Enter

Tone =

Numbers from Number menu

Exit

Page 82

Chapter 6 Programming Via Configuration Bar Code Symbols

Laser Redundancy Check When the laser redundancy check is enabled, two consecutive, identical decodes of a symbol must occur (after the laser scanner is triggered) before a good read is recognized by the decoder. When disabled, only one decode is required. The redundancy check produces greater immunity to substitution errors when scanning poor quality labels. *Default is Laser Redundancy Check Off.

Enter

Laser Redundancy Check

Exit

Laser Connection Detection

Enter

Use this function to automatically determine the type of scanning device connected to the decoder. If a laser scanner is detected, a combination of high pitched tones is produced. For wands, a low pitched combination is heard. For more information, refer to the Power Up Sequence found in Chapter 4. *Default is laser connection detection Off. Note: When using a hand–held laser scanner or Catalog No. 2755–L2 scan head with Laser Connection Detection enabled, do not trigger either device during power up or reset. If you hold the trigger, the decoder will act as if a wand is connected. The decoder will not recognize any laser scanners until it is reset by sending an escape sequence, or by turning the decoder OFF and then ON.

Laser Connection Detection On

Exit

Continuous Read Mode When enabled, the laser is turned on continuously instead of waiting for the trigger to be pulled. Scanning, decoding, and transmitting decoded messages occur continuously. Certain functions can now only be performed periodically. Examples are responding to commands such as to sound a tone or to send a no–read response if a symbol has not been decoded within the laser shutoff delay period. The shorter the laser shutoff delay, the more often system functions are performed. System functions are also performed every time there is a good read. When disabled, the trigger is used to initiate and terminate laser scanning. Note: Do not use this function with a Catalog No. 2755–G5 Hand–Held Laser Scanner. Note: When using a Catalog No. 2755–L2 Scan Head, the Package Detector must be disconnected. The laser is ON continuously. If the laser makes several sweeps, several decoded messages will be sent. If only one decode message per symbol is required, enable the single read mode and allow the host to control decoded transmissions using the Enable Next Read command. *Default is continuous read mode disabled.

Enter

Enable Continuous Read Mode

Exit

6–23

Page 83

Chapter 6 Programming Via Configuration Bar Code Symbols

Laser Shutoff Delay The laser shutoff delay determines how long the laser will remain ON while the trigger is enabled. The laser will remain on until a read is completed, the laser shutoff period has elapsed, or the trigger has been disabled. Regardless of the laser shutoff delay time, the laser will always be turned off when the trigger is released (unless the Trigger Latch Mode function is enabled). If the delay is set to 0, the laser will not turn on at all when triggered. *Default is 120 sweeps. Enter

Laser Shutoff Delay

Exit

Trigger Latch Mode When enabled, the laser is turned on when triggered, but is not shut off immediately when the trigger is disabled. The laser will remain on until a read is completed or the laser shutoff period has elapsed. Note: This must be enabled when using a Catalog No. 2755–L2 scanner with a package detector. This allows the scanner to continue scanning until the laser shutoff delay elapses, or a good read occurs. *Default is trigger latch mode enabled.

Enter

Enable/Disable Trigger Latch Mode

Exit

6–24

Page 84 read from a scan by OCR; it may hold reading errors

Chapter 6

Programming Via Configuration Bar Code Symbols

Number Menu

1

0

2

3 4

5 6

7

8 9

10 11

6-25

Page 85 read from a scan by OCR; it may hold reading errors

Chapter 6

Programming Via Configuration Bar Code Symbols

ANAL _ - 13

1

2

14

15 16 17

1

8

19

20 21

22 23

6-26

Page 86 read from a scan by OCR; it may hold reading errors

Chapter 6

Programming Via Configuration Bar Code Symbols

Number Menu

24

5

2

26

27 28

29 30

37

32 33

40

50

6-27