Page 69

Chapter 6 Programming Via Configuration Bar Code Symbols

Code 11 Used to enable and disable Code 11.

Enter

*Default is Code 11 enabled. Enable/Disable

Exit

Selecting the Number of Code 11 Check Characters Check character verification of Code 11 is mandatory. The number of check characters may be one or two. If the length of the data is less than or equal to ten, one check character is normally used. If more than ten data characters are present, two check characters are used. If the check character is incorrect, then the bar code symbol will be ignored, or if no–read recognition is enabled, a no–read message will be transmitted. For more information on check characters, refer to page 5–14. *Default is 1 Check Character.

Enter

Check Digit

Exit

Enter

Min Length =

Number from Number menu

Minimum and Maximum Lengths The length of a decoded bar code may be checked to see if it matches a set of predefined (configurable) limits. If the length of the bar code is within these limits, it is accepted as valid. If the length is outside the limits, a no–read condition exists. Default minimum length is 1, default maximum length is 32 The length to be checked includes any check characters but does not include start and stop characters. If you want to check for a specific length, the minimum and the maximum should be set to the same number. Setting the maximum less than the minimum (or the minimum more than the maximum) will cause a syntax error.

6–10

Max Length =

Number from Number menu

Exit

Page 70

Chapter 6 Programming Via Configuration Bar Code Symbols

Enable UPC/EAN

Enter

Used to enable and disable UPC/EAN. *Default is UPC/EAN enabled.

Enable/Disable

Exit

Read UPC Versus UPC/EAN All versions (UPC A, UPC E, EAN 8, or EAN 13) may be automatically recognized and decoded. You may restrict the code to only UPC–A and UPC–E. EAN–13 and EAN–8 symbols will not be decoded. *Default is Read UPC or EAN.

Enter

UPC Only or UPC/EAN

Exit

Expand UPC

Enter

UPC–E symbols may be expanded into the UPC–A format. *Default is UPC–E Not Expanded.

Expanded or Not Expanded

Exit

6–11

Page 71

Chapter 6 Programming Via Configuration Bar Code Symbols

Supplemental Digits (UPC/EAN) Supplemental characters may be enabled. If they are enabled, the symbol must be scanned in the forward direction, supplemental characters last. If the symbol is scanned backwards, for instance with the reverse sweep of a laser scanner, or the symbol does not have supplemental characters, the symbol will not be decoded. By specifying the supplement, you will not miss the supplemental characters (unless they are not present). There are three configurable options: Symbols with two digit supplemental characters may be read. Symbols with five digit supplemental characters may be read. Symbols with two or five digit supplemental characters may be read. *Default is No Supplements.

Enter

• No Supplements • 2 digit only • 5 digit on;y • 2 & 5 digit Exit

Autodiscriminate Supplements (UPC/EAN)

6–12

Automatic recognition of supplemental characters may be enabled. This allows you to decode a symbol with or without supplemental characters.

Enter

If supplemental characters are present in the symbol, the symbol must be scanned in the forward direction, supplements last. If the symbol is scanned in the opposite direction, with the supplements first, or the scan misses the supplemental characters, the supplements will not be decoded. *Default is Supplements Required If Enabled.

Required or Autodiscriminate

Exit

Page 72

Chapter 6 Programming Via Configuration Bar Code Symbols

Codabar

Enter

Used to enable and disable Codabar. *Default is Codabar enabled. Enable/Disable

Exit

Enter

Min Length =

Minimum and Maximum Lengths (Codabar) The length of a decoded bar code may be checked to see if it matches a set of predefined (configurable) limits. If the length of the bar code is within these limits, it is accepted as valid. If the length is outside the limits, a no–read condition exists. Default minimum length is 1, default maximum length is 32 The length to be checked includes any check characters but does not include start and stop characters. If you want to check for a specific length, the minimum and the maximum should be set to the same number. Setting the maximum less than the minimum (or the minimum more than the maximum) will cause a syntax error.

Number from Number menu

Number from Number menu

Max Length =

Exit

Start/Stop Character Transmission (Codabar) Codabar has the option to either transmit the start and stop characters with the message or to suppress them from the message. When suppressed, the start/stop characters are stripped from the decoded message. Codabar is the only bar code that has user information contained in the start and stop characters. *The default is start/stop character transmission Enabled.

Enter

Enabled or Suppressed

Exit

6–13

Page 73

Chapter 6 Programming Via Configuration Bar Code Symbols

Check Character Transmission

Enter

When check character verification is enabled for Code 39 and Interleaved 2 of 5, the transmission of the verified check character may be deleted from the message, or transmitted, as a data character, along with the decoded data. This option applies to both symbologies only if check character verification is enabled. The table below lists codes with mandatory check characters and indicates whether the check characters are transmitted. *Default is check character Removed.

Code

Transmit

UPC A UPC E UPC E expanded to UPC A EAN 8 EAN 13 CODE 128 CODE 11

Yes Unavailable Yes Yes Yes unavailable Yes

Code ID Character Transmission Code ID characters are single ASCII characters that can be added to the beginning of decoded bar code data. These characters indicate the symbology used to encode the data.

Check Character

Exit

Enter

Code ID

*Default is code ID characters suppressed. Exit

6–14

Page 74

Chapter 6 Programming Via Configuration Bar Code Symbols

Code ID Character Assignment Code ID characters are single ASCII characters that can be added to the beginning of decoded bar code data. These characters indicate the symbology used to encode the data. The code ID character may be suppressed or transmitted with the bar code message. See Code ID Character Transmission. The table below lists the Default ID Characters.

Code

Default

Code 39 Interleaved 2 of 5 UPC/EAN Codabar CODE 128 CODE 11 a b c d e f

Enter

ID Character =

One character from the Character Menu

Exit

6–15

Page 75

Chapter 6 Programming Via Configuration Bar Code Symbols

Baud Rate Selection Baud rate is programmable. available baud rates are:

• 600 • 1200 • 2400 • 4800 • 9600 • 19.2K *Default is 9600 Baud.

6–16

Enter

The Baud

Exit

Page 76

Chapter 6 Programming Via Configuration Bar Code Symbols

Parity

Enter

The parity of the transmitted data may be configured as odd, even, 0’s (space) or 1’s (mark). *Default parity is 0’s.

Parity

Exit

Stop Bits One or two stop bits may be transmitted at the end of each character.

Enter

*Default is 1 Stop Bit. Stop Bits

Exit

6–17

Page 77

Chapter 6 Programming Via Configuration Bar Code Symbols

RTS/CTS Handshaking When this option is enabled, the Request To Send (RTS) line is activated when the decoder has characters to transmit. Transmission proceeds when the Clear To Send (CTS) line is active.

Enter

RTS/CTS

When disabled, RTS remains inactive and CTS is ignored. * Default is RTS/CTS Enabled. Exit

Intercharacter Delay A delay time can be inserted between transmitted characters. If the intercharacter delay is disabled, then there will be no delay between characters. If the delay is enabled, then the delay period, configured independently, specifies the number of milliseconds that elapses between completed transmission of one character and beginning of the transmission of the next. * Default is Intercharacter Delay OFF. If enabled, the default delay time is 20 ms.

Enter

Delay ON

Delay =

Number form Number Menu

Exit

Fixed Serial Port Configuration at Reset When enabled, the Fixed Serial Port Configuration at Reset will set the serial port to its default configuration as soon as you reset the decoder. *Default is Disable At Reset. Note: When using a laser scanner with laser connection detection enabled, do not hold the laser scanner’s trigger during reset. If the trigger is held, the decoder will treat the laser scanner as a wand. The decoder will not recognize a laser scanner until it is reset by an escape sequence or by turning the decoder Off and then On.

6–18

Enter

Enable/Disable

Exit