Page 121

Appendix A. Understanding SNMP

SNMP Trap Configuration Traps received by the TDU 120e from external units and the host unit are converted into SNMP traps and forwarded to the configured NMS. The source of the trap is uniquely identified at the NMS by a combination of the IP address of the TDU 120e, and the Unit ID of the sending device. The Unit ID is present in the trap packet appended to the end of the trap community packet name, for example public.4. It is also included as an Octet String variable (adProdPhysAddress) in the trap packet as defined in the individual product MIBs. The latest versions of the product MIBs, by default, display the appended trap community name in their descriptions. Typical steps required for Management Station trap configuration are: 1.

loading the device specific MIBs, and

2.

loading or creating device-specific Trap Definition Files.

The current product MIBs contain keywords embedded in comments that can be used by some network management platforms to automatically generate Trap Definitions. Otherwise, the descriptions may be used as a template for Trap Definitions. If individual option card port and slot identification is required, it is present in the four-byte adProdPhysAddress field of the trap packet. The first two bytes are the Unit ID of the base controller (least significant byte first). The next two bytes are port and slot number. This field is the second object identifier in all traps sent from TSU/TDU products. For traps from the ISU 512, the Unit ID is the first object identifier. See the product MIBs for more information. Definitions for Poll Link Up/Down traps are included in the TDU 120e MIB file: TDU 120e.MIB.

61202156L2-1

TDU 120e User Manual

A-5

Page 122

Appendix A. Understanding SNMP

SNMP MIB Browser Configuration The following steps are required to configure Network Manager MIB variable access through the TDU 120e: Step

1

Action Load the desired product MIBs on the network management station. Example: If the administrator is managing TDU 120e and ISU 512 devices, load TDU 120e.MIB, ISU512.MIB, and RFC1406.MIB.

2

Create device entries in the NMS database for all units that are to be managed through the TDU 120e. The host unit should be configured as the Proxy agent for the external units. The IP address or host name used for the proxy designation is that of the TDU 120e.

3

Set community names in the device’s entries for external units to the TDU 120e community name with the device Unit ID appended. See TDU 120e SNMP ACCESS on page A-4 for more information.

4

A-6

Set the device timeout for all device entries in the NMS device database to five seconds, including the host unit.

TDU 120e User Manual

61202156L2-1

Page 123

Appendix A. Understanding SNMP

SNMP MIB Files The TDU 120e supports several standard MIBs including: •

MIB-II (RFC-1213),

•

DS1 T1/E1 MIB (RFC-1406), and

• the Ethernet MIB (RFC-1643).

It also supports several ADTRAN enterprise-specific MIBs including: •

ADTRAN Product MIB (ADTRAN.MIB),

•

ADTRAN DS1 extensions MIB (ADS1.MIB), and

• all TSU/TDU Enterprise MIBs, such as TDU 120e.MIB.

The standard MIB files are usually included with most SNMP network management software. The latest version of the ADTRAN enterprise specific MIBs are available in the following places:

61202156L2-1

•

ADTRAN anonymous ftp site: ftp.adtran.com

•

Dial-up: BBS (256 -963-8169).

•

Adtran web site: http://www.adtran.com.

TDU 120e User Manual

A-7

Page 124

Appendix A. Understanding SNMP

A-8

TDU 120e User Manual

61202156L2-1

Page 125

Connector Pinouts

Appendix B

WIRING Network On the rear of the TDU 120e are two connectors labeled NETWORK. These connectors are used for connecting to the network. See Table B-1 for the pinout for the 8-pin modular connector and Table B-2 on page B-2 for the pinout of the male 15-pin D-connector. Table B-1. Network Pinout of the 8-Pin Modular Connector Pin

Name

1

R1 RXDATA-RING

Receives data from the network

2

T1

Receives data from the network

3

RXDATA-TIP UNUSED

4

R

TXDATA-RING

Sends data toward the network

5

T

TXDATA-TIP

Sends data toward the network

6,7,8

61202156L2-1

Description

UNUSED

TDU 120e User Manual

B-1

Page 126

Appendix B. Connector Pinouts

Table B-2. Network Pinout of the Male 15-Pin D-Connector Pin

Name

Description Sends data toward the Network

1

T

TX DATA TIP

2

FG

FRAME GROUND

3

T1

RXDATA-TIP

4

FG

FRAME GROUND

5,6,7,8

Receives data from the Network

UNUSED

9

R

10

TXDATA-RING

Sends data toward the Network

UNUSED

11

R1

12,13,14,15

RXDATA-RING

Receives data from the Network

UNUSED

Control In/Chain In This is used as an RJ-45 port for connection to a computer or modem (Control In) or to another TSU/TDU family multiplexer or TSU 100 (Chain-In). See Table B-3 for the pinout for the control/chain-in connector. Table B-3. Control In/Chain In Pinout Pin

B-2

Name

Description

1

GND

Ground - connected to unit chassis

2

RTS

Request to send - flow control

3

RXDATA

Data received by the TDU 120e

4

UNUSED

5

TXDATA

Data transmitted by the TDU 120e

6

Ext Alarm A

When grounded, generates Alarm A

7

Ext Alarm B

When grounded, generates Alarm B

8

CTS

Clear-to-send-flow control

TDU 120e User Manual

61202156L2-1

Page 127

Appendix B. Connector Pinouts

Control-Out/Chain-Out This is used to connect to another TDU/TSU family multiplexer chain-in connector. See Table B-4 for the pinout for the chain-out connector. Table B-4. Chain-Out Pinout Pin

Name

1

GND

2

UNUSED

3

TX DATA

4

UNUSED

5

RX DATA

Description Ground - connected to unit chassis.

Data transmitted to chained units by the TDU 120e. Connect to RX DATA of the next unit (chain-in pin 3).

Data received from chained units by the TDU 120e. Connect to TX DATA of the next unit (chain-in pin 5).

6,7,8 UNUSED

61202156L2-1

TDU 120e User Manual

B-3

Page 128

Appendix B. Connector Pinouts

Craft Port This is used as an RJ-45 port for connection to a computer or modem (Control In) or to another TSU/TDU family multiplexer or TSU 100 (Chain-In). See Table B-5 for the pinout for the craft port connector. Table B-5. Craft Port Pinout Pin

B-4

Name

Description

1

GND

Ground - connected to unit chassis

2

RTS

Request to send - flow control

3

RXDATA

Data received by the TDU 120e

4

UNUSED

5

TXDATA

6,7

UNUSED

8

CTS

Data transmitted by the TDU 120e

Clear to send-flow control

TDU 120e User Manual

61202156L2-1

Page 129

Appendix B. Connector Pinouts

Nx56/64 DTE (V.35) See Table B-6 for the V.35 pinout Nx56/64 DTE pinout. Connector type V.35 Table B-6. V.35 Pinout for Nx56/64 DTE Pin

Name

Description

A

101

Protective ground (PG)

B

102

Signal ground (SG)

C

105

Request to send (RTS) from DTE

D

106

Clear to send (CTS) to DTE

E

107

Data set ready (DSR) to DTE

F

109

Received line signal detector (DCD) to DTE

L, J, Local loopback (LL)*

N, BB, Remote loopback (RL)*

R

104

Received data (RD-A) to DTE

T

104

Received data (RD-B) to DTE

V

115

RX clock (RC-A) to DTE

X

115

RX clock (RC-B) to DTE

P

103

Transmitted data (TD-A) from DTE

S

103

Transmitted data (TD-B) from DTE

Y

114

TX clock (TC-A)

AA

114

TX clock (TC-B)

U

113

External TX clock (ETC-A) from DTE

W

113

External TX clock (ETC-B) from DTE

NN, Test mode (TM) to DTE

*(ignored by TDU 120e)

61202156L2-1

TDU 120e User Manual

B-5

Page 130

Appendix B. Connector Pinouts

Base DS-1 (PBX) On the rear of the TDU 120e are two connectors labeled DS-1. These connectors are used for connecting to a PBX or other terminal equipment. See Table B-7 for the pinout of the 8-pin modular connector and Table B-8 on page B-7 for the pinout of the female 15-pin D-Connector. Table B-7. Base DS-1 Pinout of the 8-Pinout Modular Connector Pin

Name

Description

1

R1 TXDATA-RING

Sends data toward the DTE (PBX)

2

T1 TXDATA-TIP

Sends data toward the DTE (PBX)

3

UNUSED

4

R

RXDATA-RING

Receives data from the DTE (PBX)

5

T

RXDATA-TIP

Receives data from the DTE (PBX)

6, 7, 8

B-6

UNUSED

TDU 120e User Manual

61202156L2-1