This two-page spec sheet covers the ADTRAN TDU 120e (TDU 120e AC and TDU 120e DC), a T1/FT1 rackmounted DSU/CSU with embedded SNMP. It describes the V.35 and DSX-1 interfaces, the expansion slot and management options, and lists the specifications and ordering part numbers.

Device
T1/FT1 DSU/CSU in a 1U high 19-inch rackmount enclosure, with embedded SNMP p. 1
Part numbers
TDU 120e AC 1202156L1; TDU 120e DC 1202155L1; V.35 Y cable 1200196L1 p. 2
Data port
Base V.35 at Nx56 or Nx64 Kbps (N=1 to 24), V.35 Winchester type 34 pin connector p. 1, 2
DSX-1 port
Short haul DSX-1 on RJ-48C for a PBX or similar device, 0-655 ft p. 1, 2
Network interface
T1 (1.544 Mbps) on RJ-48C, D4/ESF framing, AMI/B8ZS, input signal 0 to -36dB p. 2
Management
SNMP gets, sets and traps over 10BaseT Ethernet (RJ-45) or SLIP (EIA-232); Telnet; TFTP support p. 1, 2
Expansion slot
One rear slot takes an option module of the kind used in ADTRAN TSU units p. 1
Dial backup
On the base V.35 port with the optional V.35 Y cable; DTR dialing p. 2
Power
120 vAC, 9 W (AC version); 21-26 vDC or 40-56 vDC, 40 W (DC version) p. 2
Size and weight
1.7 in H, 11.625 in D, 17 in W; 7 lbs p. 2
Operating temperature
0° to 50°C (32° to 122°F); storage -20° to 70°C p. 2
Tests
Local and remote payload/line loopbacks, V.54 on the DTE, 511 and QRSS test patterns p. 2
Performance monitoring
Network interface data kept for the last 24 hours in 15 minute steps; ANSI performance report messages p. 2
DS0 maps
Stores two DS0 maps and can switch configurations at set times p. 1

What this sheet walks you through

  • Features, interfaces and management of the TDU 120e p. 1
  • Network, DTE, DSX-1, management and physical specifications p. 2
  • Ordering the AC or DC unit and the V.35 Y cable p. 2

Good to know

  • Dial backup needs the optional V.35 Y cable. p. 2
  • Specifications are subject to change without notice. p. 2

Questions this sheet answers

What is the part number of the TDU 120e DC version?

The TDU 120e DC is 1202155L1; the AC version is 1202156L1. p. 2

What cable does TDU 120e dial backup need?

The optional V.35 Y cable, part number 1200196L1, on the base V.35 DTE port. p. 2

How is the TDU 120e managed over a network?

Through its built-in SNMP agent over 10BaseT Ethernet or a SLIP (EIA-232) connection; Telnet and PING are also listed. p. 1, 2

What data rates does the TDU 120e V.35 port support?

Nx56 or Nx64 synchronous rates, where N is 1 to 24, using channels that can be picked at random. p. 1

The file

Size and text

Pages2
PDF460 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Adtran TDU-120 Spec Sheet

The text of page 1, from the PDF itself

TDU 120e T1/FT1 Rackmounted DSU/CSU with Embedded SNMP

Product Features

  • T1/FT1 DSU/CSU
  • 1U high 19" rackmount

enclosure

  • NEBS complaint
  • V.35 interface operates at

data rates of Nx56 or Nx64 where N=1 to 24

  • Provides a base V.35 with

DBU and DSX-1 interface

  • Embedded SNMP

management

  • TFTP Support
  • Slot accepts option

modules used in ADTRAN’s TSU units

  • Ability to store two DS0

maps and switch configurations at predetermined times

  • Front panel test and

monitor jacks

  • LEDs on the front panel

The TDU 120e (T1 Distribution Unit) is an intelligent, full-featured, NEBS compliant, T1 DSU/CSU in a 1U high 19-inch rackmount enclosure. Designed to interface customers data terminal equipment (DTE) to T1 or fractional T1 services, the TDU 120e is fully compatible with D4 or ESF framing formats with AMI or B8ZS coding. When in ESF framing mode, the unit satisfies ANSI T1.403 and AT&T 54016 modes for utilization of the facility data link (FDL). It uses option modules identical to those used with ADTRAN® TSU™ units. The TDU 120e also provides complete monitoring and control of the T1 network with embedded simple network management protocol provided through both a SLIP and a 10BaseT ethernet interface.

short haul T1 interface intended for connection to a PBX, cellular/PCS switch or similar device. The channels used by the DSX-1 port can also be selected at random. To further add to the flexibility of the TDU 120e a slot on the rear of the unit is featured that accepts a single expansion module. A wide variety of application specific modules are available to provide flexibility and expandability. Configuration and management of the TDU 120e is available through a variety of methods. The TDU 120e supports SNMP with gets, sets, and traps functionality through a built-in agent. ADTRAN® MIBs support management for the TDU 120e and all installed expansion modules. For access to SNMP features, the TDU 120e has both a 10BaseT Ethernet and a SLIP (EIA-232) connection. In addition to SNMP, the unit utilizes the management capabilities found in a variety of optional software products from ADTRAN.

A base V.35 and DSX-1 (PBX) interface is provided on the rear of the unit. The V.35 interface can be configured to operate synchronously at Nx56 or Nx64 data rates where N=1 to 24. The channels used can be selected at random. The DSX-1 interface is a

indicate the status of each port

  • 8 Kbps inband manage-

Network

ment channel

  • Optional Management

DSX-1SoftwareT1/FT1 PBXTDU 120e■ AC and DC versionsavailableV.35REMOTE ACCESSACOCRAFTNETWORK INOUTMON PORT 0.2 INOUTINOUTMON INOKREDOUT TEST ALARMYEL ERRORNETWORKOKTDU 120eACTEST ALARMSTATUS0.10.2PORT 1.1 1.1PORT STATUS1.21.31.4INOUTMON INOUTEthernet LANPC

Management Software (optional)

V.35 V.35 Video-Conferencing Equipment

Router

Ethernet LAN

Page 2 of Adtran TDU-120 Spec Sheet

The text of page 2, from the PDF itself

TDU 120e CORPORATE OFFICE ADTRAN, Inc. 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000

800 9ADTRAN 256 963-8000 fax: 256 963-8699 fax back: 256 963-8200 e-mail: info@adtran.com web site: www.adtran.com

T1/FT1 Rackmounted DSU/CSU with Embedded SNMP

Product Specifications Network Interface

  • Line Rate: T1 (1.544 Mbps)
  • Physical: RJ-48C
  • Framing: D4/ESF
  • Line Code: AMI/B8ZS

Management Options Control In / Control Out Ports

  • Interface: EIA-232, PC serial port, modem or

SLIP connection to router

  • Physical Connector: RJ-45, modular 8-pin

10BaseT Interface

REGIONAL OFFICES Chicago, IL 800 436-4217

  • ESF: AT&T 54016 or ANSI T1.403
  • Input Signal: 0 to –36dB
  • Interface: IEEE 802.3 compliant, 10 Mbps

Seattle, WA

  • DS0 Assignment: User selectable
  • Physical Connector: RJ-45, modular 8-pin
  • T1 Transmit Timing: Loop timed, internal, Base DSX-1,
  • Service: SNMP, Telnet, ICMP, ARP, PING,

800 390-1573

Washington, DC 800 794-9798

Base DTE, or secondary interface (if installed)

Atlanta, GA

FIELD OFFICES 800 289-0966

Chicago, IL

800 471-8655

  • Data Rate: Nx56/64 Kbps (N=1 to 24)

Columbus, OH

888 865-2237

  • Electrical: CCITT V.35

DTE Interface (DBU Capable)

  • Mechanical: V.35-Winchester type 34 pin

Dallas, TX800 471-8648Denver, CO800 471-8651Irvine, CA800 788-5408

  • Accessible on base V.35 DTE Port

Kansas City, KS 800 471-8649

  • Requires optional V.35 “Y” cable

Los Angeles, CA 888 223-7668

  • DBU Dialing: DTR dialing

Nashville, TN

888 223-7657

  • DBU Test: Loopback to DCE, test dialup network,

New York, NY800 471-8657force dial backupPortland, OR888 223-7660DSX-1 InterfaceRichmond, VA800 689-9915

  • Line Length: 0-655 ft

San Jose, CA888 223-7655■ Physical: RJ-48CINTERNATIONAL CONTACTS

Beijing, China 8610 8529-8895 Canada 1 877 923-8726 Hong Kong 52 2824-8283 Latin America 954 474-4424 London, U.K. 44 1252 626-730 Melbourne, Australia 61 3 9225-5114 Mexico/Caribbean 954 577-0357 Zürich, Switzerland 41 1 880-2777

Dial Backup

  • Framing: D4/ESF
  • Line Coding: AMI/B8ZS

Physical

  • Dimensions: 1.7" H, 11.625" D, 17" W fits

1U high 19" rack space

  • Weight: 7 lbs
  • Power

120 vAC, 9 W (AC) 21-26 vDC 40 W (DC) 40-56 vDC, 40 W (DC)

Agency Approvals

  • UL 1950, CUL
  • FCC Part 15 (Class A)
  • FCC Part 68
  • GR 1089 and GR 63

Environment

  • Operating Temperature: 0° to 50°C, (32° to 122°F)
  • Storage Temperature: –20° to 70°C, (–4° to 158°F)

Tests

  • Remote: Payload/Line (NI) V.54 (DTE)

Ordering Information

  • Pattern: 511 (selectable DS0s), QRSS

Equipment

  • Local: Payload/Line (NI)

(selectable DS0s)

Performance Monitoring

  • Error Counts: ES, SES, UAS, % AS, % EFSEC,

Alarms, error rates

  • Reports: NI information stored for last
  • 24 hours in 15 minute increments
  • PRMS: ANSI Performance Report Messages

(selectable)

ADTRAN is a ISO 9001 registered company.

ADTRAN is a TL 9000 registered company. Printed in the U.S.A. 61202156L1-8B November 2001 ©2001 ADTRAN, Inc. All rights reserved.

T-Watch PRO™

Specifications subject to change without notice. ADTRAN is a registered trademark of ADTRAN, Inc. All other registered trademarks and trademarks mentioned in this publication are the property of their respective owners.

Part #TDU 120e AC1202156L1TDU 120e DC1202155L1V.35 “Y” Cable1200196L1

More documents · 1

For the same models