Chapter 1. NT1 ACE Overview The ADTRAN NT1 ACE provides an interface between customer ISDN terminal equipment (TE) and the basic rate ISDN network (U). Figure 1-1 is an illustration of the NT1 ACE.
READY
NT1 ACE
ERROR POWER
Figure 1-1. ADTRAN NT1 ACE Three jacks are provided on the rear panel of the unit for connecting the ISDN circuit and user equipment to the NT1 ACE (see Figure 1-2).
S/T
S/T LOCAL
NETWORK POWER U
Figure 1-2. Interface Connectors A single RJ-49C connector labeled NETWORK U connects to the ISDN network. Two data jacks labeled S/T connect to the S/T interface of the customer’s TE.
61203019L1-1
NT1 ACE User Manual
1
Page 18
NT1 ACE Overview
The ADTRAN NT1 ACE is a stand-alone unit, and is powered by an external power supply. The NT1 ACE can be ordered with the power supply included (Part Number 1203019L1), or the power supply, Part Number 336048VUR2, can be ordered separately. The NT1 ACE can supply power to TE attached through the S/T interface.
LED Indicators Table 1-1 describes the status of the LEDs located on the front panel of the NT1 ACE. Table 1-1. Status Indicators
2
POWER
ERROR
READY
Off
--
--
Unit does not have power.
Solid Green
--
--
Unit has power.
Solid Green
Off
Solid Green
S/T and U interfaces are ready.
Solid Green
Solid Red
Slow Flashing Green
S/T interface problem.
Solid Green
Solid Red
Fast Flashing ISDN Network problem Green
NT1 ACE User Manual
Description
61203019L1-1
Page 19
Chapter 2. Installation Before Installing the NT1 ACE After unpacking the NT1 ACE, carefully inspect it for shipping damage. If damage is suspected, file a claim immediately with the carrier and contact ADTRAN Technical Support. If possible, keep the original shipping container for use in shipping the NT1 ACE for repair or for verification of damage during shipment.
Setting the Option Switches Two option switches located on the side of the unit configure the Local Bus of the NT1 ACE, as shown in Figure 2-1.
LOCAL BUS CONFIGURATION SHORT
LONG
TERMINATION 50 100
NONE
Figure 2-1. Switch Locations Termination Switch For reliable operation, the S/T bus must be properly terminated. In addition to the termination resistor provided in the NT1 ACE, bus termination resistors can be provided in the TE or externally. (See Table 2-2 on page 9 for pin assignments.)
61203019L1-1
NT1 ACE User Manual
3
Page 20
Installation
TE can provide termination resistor: Enable 100 ohm termination resistor on one TE, and disable the termination reistor on all other TE(s) attached to this bus. If all of the unterminated TE(s) are within 20 feet of the NT1 ACE, set the NT1 ACE’s termination switch to 50. Otherwise, set the NT1 ACE’s termination switch to 100.
TE does not provide termination resistor: In this case, an external terminating resistor must be used, and the NT1 ACE’s termination switch should be set to NONE. Configuration Switch The configuration switch is set according to how far away the TEs are from the NT1 ACE. When the configuration switch is set to SHORT, the maximum allowable distance between the NT1 ACE and the furthest TE is 600 feet, as shown in Figure 2-2. When the configuration switch is set to LONG, the maximum allowable distance between the NT1 ACE and the furthest TE is 3000 feet, as shown in Figure 2-3.
4
NT1 ACE User Manual
61203019L1-1
Page 21
Installation
600 Feet * TR
TR
TE
TE
TE
NT1
*Not needed if NT1's Termination Resistors (TR) are used.
Figure 2-2. Short Passive Bus Configuration
3,000 Feet 160 Feet
* TR
TR
NT1
*Not needed if NT1's TE
TE
Termination Resistors (TR ) are used.
Figure 2-3. Extended Passive Bus Configuration
61203019L1-1
NT1 ACE User Manual
5
Page 22
Installation
Powering with the NT1 Power Supply The ADTRAN NT1 Power Supply, part number 336048VUR2, provides up to 10 watts of power at -48 VDC. The NT1 ACE requires 1.1 watts, leaving approximately 8.9 watts to power the TE(s). Before connecting any TE to be powered from the NT1, verify that the total power requirement of the connected TE is less than 8.9 watts. To connect the NT 1ACE to the NT1 Power Supply, perform the following steps as illustrated in Figure 2-4. 1. Connect the Power Supply to the NT1 ACE at the POWER jack located on the NT1 ACE. 2. Plug the Power Supply into the nearest wall outlet supplying 110 VAC, 60 HZ. 3. On the NT1 ACE, verify that the POWER and ERROR indicators are illuminated. After approximately 15 seconds, the READY indicator should flash at a 1 Hz rate. Should any of the indicators fail to operate as stated, see the section Troubleshooting on page 10. LOCAL
ADTRAN
POWER
ERROR
READY
100 - 120 VA C
NETWORK
ISDN PS2
POWER
Figure 2-4. Power Supply Connection 6
NT1 ACE User Manual
61203019L1-1
Page 23
Installation
Connecting the Terminal Equipment After successfully powering up the NT1 ACE, the POWER and ERROR indicators should be on and the READY indicator should be flashing. Make sure that terminal equipment (TE) is properly terminated as instructed in Setting the Option Switches on page 3. Plug the TE into one of the Local Bus connectors at the rear of the unit. A second TE may be plugged into the remaining Local Bus connector. If more than two TEs need to be connected to the NT1 ACE, additional connections can be made in parallel to the S/T bus using RJ-45 connectors. TEs commonly have additional jacks wired in parallel. These may be used to connect more than two TEs as provided for by the NT1 ACE. See the TE documentation for further information. After the TE powers up, the ERROR indicator should go out. There may be some delay between plugging in the TE and the ERROR indicator going out, depending on the specific TE in use. If the ERROR indicator fails to go out, see the section Troubleshooting on page 10. As the ERROR indicator extinguishes, the READY indicator should illuminate. The TE will now be ready to place and receive calls. There may be a slight delay between the appearance of the READY indicator and the TE’s ability to place and receive calls, depending on the specific TE in use. If the READY indicator fails to illuminate or if you are unable to place or receive calls, see the section Troubleshooting on page 10. 61203019L1-1
NT1 ACE User Manual
7
Page 24
Installation
Powering TEs from the NT1 ACE The ADTRAN NT1 ACE can be used to provide power for TEs connected to the S/T interface. The NT1 ACE supplies power by a separate wire pair (PS2) on the two data jacks marked S/T, as shown in Figure 2-1. The ADTRAN NT1 ACE SP, part number 1203019L3, also incorporates power source 1 (PS1) which provides power over the transmit and receive pairs. Before attempting to power any TE from the NT1 ACE, verify that it can accept power from a PS1 or PS2 power source. Table 2-1 gives network connector pin assignments, and Table 2-2 provides guidelines for properly terminating the local bus.
8