Spec sheet · Adtran
Adtran NT1 ACE Spec Sheet
Spec sheet2 pagesPDF 404 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
ADTRAN two-page product sheet for the NT1 ACE, a desktop ISDN network termination for 2B1Q basic rate service. It describes the U and S/T interfaces, S/T bus wiring limits, power for terminals, indicators, size and the ordering part number.
- What it is
- ISDN network termination (NT1) giving a 2B+D basic rate interface between terminal equipment and the ISDN network p. 1
- Interfaces
- U interface to the ISDN network; S/T interface to the terminal equipment p. 1
- Standards
- ANSI T1.601-1992 and ANSI T1.605-1991 p. 1
- S/T bus
- Up to eight passive bus devices: within 50 meters of each other over the full 1,500 meter range, or any spacing within 200 meters p. 1
- Termination
- Selectable 50 Ohm, 100 Ohm, or unterminated p. 1
- Power
- Included wall-mount power supply; 110 VAC, 60 Hz, 1.1 W dissipation; sources up to 8.9 W of S/T power for terminals p. 1, 2
- Overcurrent protection
- Automatically limits S/T current during an overcurrent fault until it is removed p. 1
- Indicators
- Three LEDs: Power, Network Ready, Network and Customer Errors p. 1
- Network data rate
- 160 kbps total, 144 kbps available to the customer, full-duplex p. 2
- Customer interface
- 4-wire (Tx and Rx pair), full-duplex, 192 kbps total with 144 kbps available, alternate mark inversion p. 2
- Size and weight
- 1.35 in. H, 3.75 in. D, 6.25 in. W; 2 lbs p. 2
- Environment
- Operating 0 to 50 C; storage -20 to 70 C; up to 95% humidity, non-condensing p. 2
- Line protection and tests
- U-interface lightning protection; responds to Quiet Mode and Insertion Loss Test p. 1
- Part number
- NT1 ACE & wallmount power supply 1203019L1; includes a manual and a 6 ft. RJ45 to RJ45 telephone cable p. 2
What this sheet walks you through
- Wiring several ISDN terminals on the S/T bus p. 1
- Choosing the termination impedance p. 1
- Reading the status LEDs for fault isolation p. 1
- Line interface electrical specifications p. 2
Good to know
- The housing is plastic, meant for desk-top use. p. 1
- Specifications are subject to change without notice. p. 2
Questions this sheet answers
How many ISDN devices can connect to the NT1 ACE?
As many as eight passive bus devices on the S/T interface. p. 1
Does the NT1 ACE power ISDN phones?
Its included wall-mount power supply provides up to 8.9 W of power for terminal equipment. p. 1
What is the ADTRAN NT1 ACE part number?
1203019L1, for the NT1 ACE with its wallmount power supply. p. 2
What does an NT1 ACE do?
It terminates 2B1Q ISDN basic rate service, joining the U interface from the network to the S/T interface for terminal equipment. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
NT1 ACE ISDN Network Termination
Product Features
- Compatible with 2B1Q
basic rate services and standard ISDN terminals
- Provides 2B+D basic rate
service
- Conforms to ANSI T1.601-
1992 and ANSI T1.605-1991
- Supports multiple switch
vendors Lucent 5ESS, NTI DMS-100, Siemens EWSD, NEC, and National ISDN-1
- Responds to Quiet Mode
and Insertion Loss Test
- Provides automatic over-
current protection for S/T power
- Selectable terminating
impedance; 50 Ohm, 100 Ohm, or unterminated
- Provides U-interface light-
ning protection
The ADTRAN® NT1 ACE™ provides the network termination for 2B1Q ISDN basic rate service. The NT1 ACE provides a 2B+D basic rate interface between the subscriber’s terminal equipment and the ISDN network. Basic rate ISDN consists of two 64 kbps B channels and a single 16 kbps D channel. Connection to the ISDN network is made with a U interface. Connection to the subscriber’s terminal equipment is by an S/T interface. The U and the S/T interfaces conform to ANSI and CCITT standards and perform all Layer 1 functions. The NT1 ACE is designed with aesthetics as well as functionality in mind. The unit is enclosed in an attractive, durable plastic housing appropriate for desk-top use. The NT1 ACE is powered by the wall-mount power supply included with the unit. The wallmount power supply provides up to 8.9 W of power for terminal equipment. The NT1 ACE monitors the S/T interface for overcurrent fault conditions. In the event of such a condi-
tion, the unit automatically limits the amount of delivered current until the fault condition is removed. As many as eight passive bus devices may be connected to the S/T interface of the NT1. These connections can be in one of the following two modes: multiple terminals within 50 meters of each other over the full 1,500 meter range of the interface, or multiple terminals of arbitrary spacing within 200 meters. Also, termination impedance options include 50 Ohm, 100 Ohm, or unterminated. The NT1 ACE is protected from lightning and harmful line transients on the network interface. Three LED status indicators on the NT1 ACE aid in fault isolation. Indicators display the status for Power, Network Ready, Network and Customer Errors.
- Standard five-year
warranty
Telephone Company Office
ISDN Switch
Customer Premises U-Interface Local Loop
READY ERROR POWERNT1 ACES/T BUS
VideoConference Equipment
NT1 ACE
ISDN Phone
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
NT1 ACE CORPORATE OFFICE ADTRAN, Inc. 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000
800 9ADTRAN 256 963-8000 fax: 256 963-8699 fax back: 256 963-8200 e-mail: info@adtran.com web site: www.adtran.com
REGIONAL OFFICES Chicago, IL 800 436-4217 Seattle, WA
800 390-1573
Washington, DC 800 794-9798
ISDN Network Termination
Product Specifications Network Interface
- Manual
- Operating Mode: Full-duplex
- NT1 ACE
- Data Rate: 160 kbps total; 144 kbps available to cus-
- 6 ft. telephone cable (RJ45 to RJ45)
tomer
Atlanta, GA Chicago, IL
800 471-8655Columbus, OH888 865-2237Dallas, TX800 471-8648Denver, CO800 471-8651Irvine, CA800 788-5408
- Output Amplitude: 2.5 V, Zero-to-Peak
- Tx Source Impedance: As per ANSI T1.601-1992
- Rx Source Impedance: As per ANSI T1.601-1992
Customer Interface
- Line: 4-wire (Tx and Rx Pair)
- Operating Mode: Full-duplex
- Data Rate: 192 kbps total; 144 kbps available to cus-
tomer
- Signal Format: Alternate mark inversion, 100% duty
cycle
Kansas City, KS 800 471-8649
- Output Amplitude: 0.75 V, Zero-to-peak
Los Angeles, CA 888 223-7668
- Tx Source Impedance: As per ANSI T1.605-1991
Nashville, TN
888 223-7657
- Rx Source Impedance: As per ANSI T1.605-1991
New York, NY
800 471-8657
- Receiver Sensitivity: As per ANSI T1.605-1991
Portland, OR888 223-7660Richmond, VA800 689-9915San Jose, CA888 223-7655INTERNATIONAL CONTACTS
Beijing, China 8610 8529-8895 Canada 1 877 923-8726 Hong Kong 52 2824-8283 Latin America 954 474-4424 London, U.K. 44 1252 626-730 Melbourne, Australia 61 3 9225-5114
Switch Compatibility
- Lucent 5ESS, NTI DMS-100, NEC National ISDN-1
Physical
- Size: 1.35" H, 3.75" D, 6.25" W
- Weight: 2 lbs
- Power: 110 VAC, 60 Hz, 1.1 W dissipation Sources S/T
power to 8.9 W
Environmental
- Operating Temperature: 0° to 50°C, 32° to 122°F
- Storage Temperature: -20° to 70°C, -4° to 158°F
- Relative Humidity: Up to 95%, non-condensing
Approvals
- FCC Part 15, Class B
- FCC Part 68
- UL
Mexico/Caribbean 954 577-0357
- CUL
Zürich, Switzerland 41 1 880-2777
- CSO3
- CSA
ADTRAN is an ISO 9001 registered company. Printed in the U.S.A. 61203019L1-8D October 2001 ©2001 ADTRAN, Inc. All rights reserved.
- 110 V wallmount power supply
- Signal Format: 2B1Q
- Receiver Sensitivity: As per ANSI T1.601-1992
FIELD OFFICES 800 289-0966
Product Includes
- Line: 2-wire (TIP and Ring)
Specifications subject to change without notice. ADTRAN is a registered trademark of ADTRAN, Inc.
Ordering Information Equipment
NT1 ACE & wallmount power supply
Part #
1203019L1