Page 141

Glossary

NT2 Network Termination 2. A unit that provides switching and concentration of subscriber lines at the S-interface. This unit performs the functions of a customer premises switch or multiplexer to multiplex B-channel(s) and D-channel(s) onto one physical path and to route calls to the appropriate B or D channel. PRA Primary Rate Access. Connects high-capacity CPE, such as PBXs, to the network. In the US, this is composed of twenty-three 64 kbps channels and one 64 kbps D-channel. Also known as Primary Rate Interface (PRI). point-to-point Describing a circuit connecting two points directly with no intermediate processing nodes or computers (although switching facilities could exist). A type of connection that links two logical entities (i.e., phone-line circuit). serving area Region surrounding a broadcasting station where signal strength is at or above a stated minimum. The geographic area handled by a telephone central office facility. Generally equivalent to a LATA. S-interface S-Reference point. The interface that connects an ISDN terminal (TE1) or Terminal Adapter (TA) to the NT2 reference point as defined in the I.411 Recommendation. SPCS Stored Program Controlled Switch. A digital switch that supports call control, routing, and supplementary services provision under software control. All ISDN switches are SPCSs. synchronous (1) The condition occurring when two events happen in a specific time relationship with each other, both under control of a master clock; (2) A method of data transmission requiring the transmission of timing pulses to keep the sender and receiver synchronized in their communication used to send blocks of information. Synchronous data transmission is used in high speed data circuits because there is less overhead than asynchronous transmission of characters which contain two extra bits per character to effect timing. T1 Also T-1. A digital transmission link with a capacity of 1.544 Mbps. T1 uses two pairs of normal twisted wires. T1 normally can handle 24 voice conversations with each conversation being digitized at 64 kbps. With more advanced digital voice encoding techniques, it can handle more voice channels. T1 is a standard for digital transmission in North America.

126

ISU 128 User Manual

61202.029L2-1

Page 142

Glossary

T1C 3.152 Mbps. Capable of handling 48 voice conversations. T1C is further up the North American digital carrier hierarchy. T2 6.312 Mbps. Capable of handling 96 voice conversations. T2 is four times the capacity of T1. T3 44.736 Mbps. Commonly referred to as 45 Mbps. Capable of handling 672 voice conversations. T3 runs on fiber optic and is typically called FT3. TA Terminal Adaptor. A DCE that connects to the ISDN S-Interface and enables non-ISDN terminal equipment to communicate over the ISDN. TE1 Terminal Equipment Type 1. ISDN-compatible terminals. TE2 Terminal Equipment Type 2. Non-ISDN terminal equipment linked at the EIS-232, RS-449, or V.35 interfaces. tandem The connection of networks or circuits in series. The connection of the output of one circuit to the input of another. T-interface T-Reference point. Performs the same function as the S-Interface but uses an NT1, rather than an NT2. twisted pair Two wires twisted around each other to reduce induction (interference) from one wire to the other. Several sets of twisted pair wires may be enclosed in a single cable. Twisted pair is the normal cabling from a central office to your home or office, or from your PBX to your office phone. Twisted pair wiring comes in various thicknesses. As a general rule, the thicker the cable is, the better the quality of the conversation and the longer cable can be and still get acceptable conversation quality. However, the thicker it is, the more it costs.

61202.029L2-1

ISU 128 User Manual

127

Page 143

Glossary

2B+D The Basic Rate Interface (BRI) in ISDN. A single ISDN circuit divided into two 64 kbps digital channels for voice or data and one 16 kbps channel for low speed data (up to 9,600 baud) and signalling. 2B+D is carried on one or two pairs of wires depending on the interface, the same wire pairs that today bring a single voice circuit int o your home or office. See ISDN. 23B+D In ISDN, also known as the Primary Rate Interface. A circuit with a wide range of frequencies that is divided in twenty-three 64 kbps paths for carrying voice, data, video, or other information simultaneously. It bears a remarkable similarity to today's T1 link, except that T1 carries 24 voice channels. In ISDN, 23B+D gives twenty-three channels and one D channel for out of band signalling. However, in T1, signalling is handled in band. See ISDN. two-wire circuit A transmission circuit composed of two wires, signal and ground, used to both send and receive information. In contrast, a 4-wire circuit consists of two pairs. One pair is used to send. One pair is used to receive. All trunk circuits (long distance) are 4-wire. A 4-wire circuit delivers better reception, but also costs more. All local loop circuits (those coming from a Class 5 central office to the subscriber's phone system) are 2-wire, unless a 4-wire circuit is requested. U-interface A twisted pair subscriber loop that connects the NT1 reference point to the ISDN network, as defined in the I.411 Recommendation. This interface provides Basic Rate Access with an operating frequency of 160 kbps and an information rate of 144 kbps. Under U.S. regulations, this also marks the line of demarcation between customerowned equipment and the public network. video-conferencing The real-time, usually two-way, transmission of digitized video images between tw o or more locations. Teleconferencing requires a wideband transmission facility. Transmitted images may be freeze-frame (where television screen is repainted every few seconds to every 20 seconds) or full motion. Bandwidth requirements for two-way video conferencing range from 6 MHz for analog, full-motion, full-color, commercial grade TV to 56 kbps for digitally-encoded freeze-frame to 1.544 kbps for very good quality, full-color, full-motion TV. wideband Generally, a communications channel offering a transmission bandwidth greater than a voice grade channel. Data transmission speeds on wideband facilities are typically in excess of 9.6 kbps and often at rates such as 56 kbps and 1.544 Mbps.

128

ISU 128 User Manual

61202.029L2-1

Page 144

Glossary

X.25 A packet data transfer protocol for the B and D Channels. Defines the interface between Data Terminal Equipment (DTE) and Data Circuit Terminating Equipment (DCE) for terminals operating in the packet mode and connected to public data networks by dedicated circuits.

61202.029L2-1

ISU 128 User Manual

129

Page 145

Glossary

130

ISU 128 User Manual

61202.029L2-1

Page 146

Index A

C answer call 68 answer tone 37 always tone 37 incoming tone 37 no answer tone 37 outgoing tone 37 asynchronous data format 45 AT command connect message options 90 remote configuration 71 response message options 89 response message types 90 AT commands 30, 87 changing S-register strings 32 changing S-registers 32 dialing a call using the AT command processor 32 reading S-register strings 32 reading s-registers 32 using AT commands 31 using S-registers 31 audio 25 auto answer disabled 36 dump all calls 36 enabled 36 cable lengths 12 call screening 38 call type 24 audio 25 data 56 kbps 25 data 64 kbps 25 default 25 speech 24, 25 calling number identifiers 88 Capability B 10 Capability C 10 Capability R 9, 10 Capability S 10 carrier detect 88 CD options 43 channel rate 41 clear channel 7, 48 clear to send control line options 89 clock mode master 40 slave 40 compression 52, 57 configuration 23 quick setup 59 remote 71 configuration menu 18 configure remote unit 73 VT 100 screen 73 connect timeout 38 connector pinouts 115 EIA-232 interface 115

B B-channel aggregation 84 bit rate 42 BONDING mode 1 7, 26, 48 61202.029L2-1

ISU 128 User Manual

131

Page 147

Index maintenance port 119 RJ-45 ISDN IFC 118 RS-366 interface 118 RS-530 116 V.35 interface 117 connector type 43 connector types EIA-232 12 RS-366 12 RS-530 12 V.35 12 CTS options 43 current status messages 93

D data 56 kbps 25 data 64 kbps 25 data bits 34 data flow control options 90 data format asynchronous flow control) 44 transmit clock 45 data format (asynchronous) 45 data rates 83 data set ready control line options 89 dial 112k sync 61 dial 115.2 asyn 64 dial 128k sync 62 dial 56K 7 dial 56k sync 60 dial 56K*2 7 dial 57.6 asyn 63 dial 64K 7 dial 64k sync 61 dial 64K*2 7 dial interface connection 12 dial line menu tree 23 operation 23 dial number 68 132 dial options 29 AT commands 30 disabled 35 front panel 29 RS-366 29 V.25 bis 33 dial ppp 62 dial stored number 68 dialing ways to dial 2 dialing options 67 answer call 68 dial number 68 dial stored number 68 hang up line 68 redial last number 68 store/review number 69 dialing selections 83 display 84 DSR options 44 DSU 57.6 async 53 DTE data rates 83 interface 83 DTE connector data synchronous data clocking options 89 DTE control line options 88 DTE data connection 12 DTE data rates 83 DTE date type options 88 DTE indicators 3 DTE interface 83 cable lengths 12 DTE options 42 bit rate 42 CD options 43 connector type 43 CTS options 43 data format (async) 45 DSR options 44 DTR options 43

ISU 128 User Manual

61202.029L2-1

Page 148

Index flow control (async data format ) 44 RTS options 43 transmit clock (sync) 45 DTR options 43 dump all calls 36

E EIA-232 12 interface 115 environmental specifications 85 EON (end of number) 30 error control 51

F factory setup 66 fallback 54 57.6k 64 FAX service 12 features 83 flow control 6, 7 flow control (async data format) 44 front panel 29 function keys 15

L

G Generic Data I 9 generic unit configurations 88 getting started 16

H hang up line 68

I if self test fails 77 if the ISU 128 does not read ready 77 installation 11 61202.029L2-1 interoperability 84 ISDN basic rate service 11 basic rate service (defined) 2 ordering codes 9 Capability B 10 Capability C 10 Capability R 9, 10 Capability S 10 Generic Data I 9 overview 1 switch protocol options 90 U-interface operational mode options 90 ISU 128 front panel 3 interoperability 4 overview 1 rear panel 2 specifications and features 83 ldm 128 master 65 LDN setting 26 LDN access options 90 leased 128K 7, 65 leased 64K 7 leased line 40 channel rate 41 clock mode 40 leased line service defined 2 LED indicators 84 local echo options 89 loopback disable 21 DDS accepted 21 DDS+V54 accept 22 no remote loopbacks 21 V.54 accepted 21

ISU 128 User Manual

133

Page 149

Index loopback DTE 20 loopback network 20 loopback points 20 loopback protocol 20 loopback remote 21 loopback remote 1B 74 VT 100 screen 75 loopback remote 2B 74

M maintenance interface 13, 119 menu navigation 15 menu tree main branches 16 microcom™ network protocol block size (MNP® blk) 52 more 65 multilink ppp 56

N NEBE/FEBE 22 negotiation fail 102 network data rates 83 interface 83 options 88 network connection 11

O operating protocols recommended 6, 7 operation 15 ordering ISDN with IOCs 9

P password remote configuration 74 physical specifications 85 134 point-to-point protocol 56 power supply 85 PPP with compression 57 ppp 7 ppp async-to-sync 56 protocol options 47 BONDING mode 1 7, 48 clear channel 7, 48 DSU 57.6 async 53 fallback 54 multilink ppp 56 ppp 7, 56 ppp async-sync 56 SAP 7, 53 T-link 7, 53 V.110 7, 51 V.120 7, 50 V.34 51 protocols rate adaption 54 recommended 6, 7

Q quick setup 59 dial 112k sync 61 dial 115.2 asyn 64 dial 128k sync 62 dial 56k sync 60 dial 57.6 asyn 63 dial 64k sync 61 dial ppp 62 factory setup 66 fallback 57.6k 64 ldm 128 master 65 leased 128K 65 V34 115.2 async 63

ISU 128 User Manual

61202.029L2-1

Page 150

Index

R rate adaption 84 rate adaption protocols 54 recommended operating protocols 6, 7 redial last number 68 remote configuration 71, 73 AT commands 71 loopback remote 1B 74 loopback remote 2B 74 menu path 72 set password 74 testing 72 VT 100 screen 72 remote testing 74 repair and return 11 RJ-45 connector 11 interface 118 jack 2 RS-366 12, 29 interface 118 menu tree 29 RS-530 12 interface 116 RTS control line options 90 RTS options 43

S SAP 7 self test failure 77 set password 74 VT 100 screen 75 Simple ADTRAN Protocol (SAP) 53 software version 22 specifications 83 speech 24 SPID obtaining 25 setting 25 61202.029L2-1

SPID access options 90 S-registers 107 status buffer 16 messages 97 status menu 17 store/review number 69 stored numbers 89 switch compatibility 84 switch protocol 24 synchronous data format transmit clock 45

T TANULL 50 TCID 50 terminal identification 25 test menu 19 test menu path 74 test menu tree 20 test options 19 loopback disable 21 loopback DTE 20 loopback network 20 loopback protocol 20 loopback remote 21 NEBE/FEBE 22 software version 22 test remote 21 test remote 21 testing 19 time-out 29 timers 49, 50 T-link 7, 53 troubleshooting 77 TXADD01 50 TXDEQ 50 TXFA 49 TXINIT 49

ISU 128 User Manual

135