Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 16

ISU 128 128 kbps ISDN Service Unit User Manual, pages 121 to 130

Pages 121 to 130 of 152

The original document is the PDF (809 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Adtran ISU 128

Page 121

Appendix C. Status Buffer Messages

106

ISU 128 User Manual

61202.029L2-1

Page 122

Appendix D S-Register List S0

AUTO ANSWER

Determines how the ISU 128 answers an incoming call. 0 = Disable (ISU 128 does not answer call). 1 = Enable (ISU 128 answers all calls). 2 = Dump all calls.

S2

BREAK IN CHARACTER

Determines which key or character (in ASCII code) defines the escape command. The standard escape character is a + sign (ASCII value of 43 decimal). To change the character set, set S2 to the desired ASCII value. Range = 0 to 127

S3

END OF LINE CHARACTER

Determines which key or character (in ASCII code) ends a command line. The standard end-of-line character is the carriage return (ASCII value of 13 decimal). Range = 0 to 127

S4

LINE FEED CHARACTER

Determines which key or character (in ASCII code) advances the cursor to the next line after ending a command line or after an ISU 128 message. The standard character is the line feed (ASCII value of 10 decimal). Range = 0 to 127

S5

BACK SPACE CHARACTER

Determines which key moves the cursor back one space to erase a character. The standard character is the backspace (ASCII value of 8 decimal). Range = 0 to 127

S7

CONNECT TIME

Determines how long the ISU 128 waits for an outgoing call to be answered. 15 = 15 seconds 30 = 30 seconds 60 = 1 minute 120 = 2 minutes 240 = 4 minutes

61202.029L2-1

ISU 128 User Manual

107

Page 123

Appendix D. S-Register List

Determines how the ISU 128 answers an incoming call if all of the protocols in Fallback failed. 1 = Clear Channel 2 = BONDING Mode 1 3 = SAP 4 = T-link 5 = V.110 6 = V.120 7 = V.34 8 = DSU 57.6 Async (default) 9 = PPP asyn-syn

S11

FALLBACK DEFAULT

S12

ESCAPE TIME

Determines the delay required immediately before and after entering the escape command for the ISU 128 to recognize and execute the command. Range = 0 to 127

S14

MISC BITS

Miscellaneous bits (bit 8 is most significant bit). Bit 2 = 1: Enables on-screen echo of AT commands. Bit 2 = 0: Disables on-screen echo of AT commands. Bit 3 = 0: Enables AT responses from the ISU 128. Bit 3 = 1: Disables AT responses from the ISU 128. Bit 4 = 1: Enables AT responses to be displayed in text form. Bit 4 = 0: Enables AT responses to be displayed in numeric form. Bit 7 = 1: Disables PPP ACCM Spoofing. Bit 7 = 0: Enables PPP ACCM Spoofing. Bit 8 = 1: Ring indicator uses cadence. Bit 8 = 0: Ring indicator remains on.

S15

ASYNC BONDING

0 = ADTRAN Only 1 = Multi-Vendor

S22

MSG BITS

Miscellaneous message bits (Bit 8 is most significant bit). Bit 5 = Bit 6 = Bit 7 = 1 : Allows connect message with baud rate. Bit 5 = Bit 6 = Bit 7 = 0 : Connects message without baud rate.

S24 V120 LLC

Value determines whether the V.120 bit is set in setup message for CCITT V.120 calls. Some terminal adapters require this bit be set to connect V.120 calls. 0 = Set V.120 bit in call setup message. (default) 1 = Do not set V.120 bit in call setup message.

108

ISU 128 User Manual

61202.029L2-1

Page 124

Appendix D. S-Register List

S27

PPP MODE

Determines type of PPP connection. 0= Single-link operation (default) 1= Multilink operation 2= Use compression

S30

DTE CTS

Controls the operation of the DTE connector clear to send (CTS) line. 0= Follows RTS 1= Force CTS

S31

DTE RTS

Controls operation of the request to send (RTS) line. 0= 1 ms delay 17= 18 ms delay

S32

DTE DSR

Controls the operation of the data set ready (DSR) signal on the DTE connectors. 0= Force DSR on always 1= DSR off OOS + Test 2= DSR off Link Down

S33

DTE CD

Controls the operation of the carrier detect (CD) line on the DTE connectors. 0= Force CD on always 1= CD is active during a call (normal operation) 2= Off with LOCD

S34 DTE DTR

Determines how the ISU 128 responds to changes in DTR. This is a bit-mapped register. 0= Ignore DTR. 1= Force AT command mode when DTR is off 2= Dump incoming call when DTR is off

S35

Determines which is the current operating DTE connector. 0= RS-530 connector 1= V.35 2= EIA-232 connector

DTE CONN

S-registers 36 through 38 require the optional V.34 modem P/N 1202029L3.

61202.029L2-1

ISU 128 User Manual

109

Page 125

Appendix D. S-Register List

S36

ERROR CORRECTION

Sets the type of error control to be negotiated with the far-end modem. 0 = Normal operation no error control. Allows speed matching, buffering, and flow control. 1 = Direct error control, no error control. Does not allow the terminal and ISU 128 to operate at different speeds or use flow control. 2 = Reliable MNP error control. If the far end does not use MNP error control then the call is ended. 3 = Auto-reliable MNP error control . The ISU 128 attempts to use MNP error control. If the far end does not use MNP, then normal operation is used. 4 = Force LAPM. Force the modem to connect only if V.42 (LAPM) error correct can be used. 5 = Force MNP. Force the modem to connect only if MNP 2-4 error correction can be used.

S37

V34 COMPRESSION

Enables compression in the V.34 modem. 0 = No compression 1 = MNP5 compression 2 = V42 compression 3 = MNPS or V42 compression

S38

V34 BLOCK SIZE

Sets the amount of data sent in a single packet during MNP error controlled stream operation. 0 = Block size of 64 bytes 1 = Block size of 128 bytes 2 = Block size of 192 bytes 3 = Block size of 256 bytes

S40

BOND TXINIT

Specifies the number of seconds the originating endpoint attempts to detect the BONDING negotiation pattern from the answering endpoint before deciding the BONDING call has failed. Range = 0 to 255, 10 sec is default

S41

BOND TXFA

Specifies the number of seconds both endpoints attempt to detect the BONDING frame pattern when a call is connected before deciding the BONDING call has failed. When operating with other manufacturers' BONDING equipment, it may be necessary to lengthen this timer so that it matches TXADD01. Range = 0 to 255, 10 sec is default

110

ISU 128 User Manual

61202.029L2-1

Page 126

Appendix D. S-Register List

S42

BOND TXADD01

The number of seconds both endpoints wait for the additional call to be connected at the end of negotiation before deciding the BONDING call has failed. When dialing overseas, it may be necessary to lengthen this timer to allow for lower call routing. Range = 0 to 255, 50 sec is default

S43

BOND TXDEQ

The number of seconds both endpoints attempt to equalize the network delay between the bearer channels before deciding the BONDING call has failed. Range = 0 to 255, 50 sec is default

S44

BOND TANULL

The number of seconds the answering endpoint attempts to detect the BONDING negotiation pattern from the originating endpoint before aborting to clear channel mode. It may be necessary to shorten this timer if the DTE equipment connected to the ISU 128 also has timer constraints for completing non-BONDING parameter negotiation. Range = 0 to 255, 10 sec is default

S45

BOND TCID

The number of seconds both endpoints attempt to negotiate agreeable values for bearer channels and channel capacities before deciding the BONDING call has failed. Range = 0 to 255, 5 sec is default

S46

V25 MODE

Selects the type of V.25 bis dialing used. 0 = Asynchronous V.25 1 = HDLC V.25 2 = BISYNC V.25 3 = HDLC with flags V.25

S47

RS-366 TIME

Determines the amount of time the RS-366 port will wait for EON or inactivity to terminate a dial string before dialing a number. 0 = Wait for EON only 10= Wait for 1 second or EON 20= Wait for 2 seconds or EON 50= Wait for 5 seconds or EON 100=Wait for 10 seconds or EON 200=Wait for 20 seconds or EON

S50

LINE MODE

Selects the operating mode of the ISU 128. 0 = Dial service (switched service) 1 = Leased service (non-switched service)

61202.029L2-1

ISU 128 User Manual

111

Page 127

Appendix D. S-Register List

S51

LINE CLOCK

Selects the clock mode in leased mode. 0 = Slave (default) 1 = Master (Leased line only, limited distance MODEM application only).

S52

SWITCH PROTOCOL

Selects the network switch type for dial service. 0 = AT&T 5ESS 1 = Northern Telecom DMS-100 2 = National ISDN-1 3 = NEC

S53

CALL TYPE

Call type (dial service only) 0 = Speech 1 = Audio 2 = 56 kbps data 3 = 64 kbps data

S54

PROTOCOL TYPE

Rate adaption protocol type. 1 = Clear Channel (no rate adaption) 2 = BONDING mode 1 3 = SAP (simple ADTRAN protocol) 4 = T-link 5 = V.110 6 = V.120 7 = V.34 9 = DSU 57.6 kbps asynchronous 11= FALLBACK 12= PPP async-to-sync

S55

DIAL MODE

Selects dialing interface. 0 = Front panel only (always available) 1 = RS-366 dialing port 2 = AT commands 3 = V.25 bis dialing

S56

ECHO TONE

Enables an echo tone which suppresses the echo cancellers in a voice circuit. Can be used to trick the switch to allow sending data over a line optioned for voice ISDN service. 0 = None 1 = Answer 2 = Originate 3 = Both

112

ISU 128 User Manual

61202.029L2-1

Page 128

Appendix D. S-Register List

Allows an ISU 128 optioned as a leased line unit to respond to DDS in-band latching loopback or V.54 loopback commands. 0 = No checking 1 = Check for DDS latching loopbacks 2 = Check for v.54 loopbacks 3 = Check for V.54 and DDS latching loopbacks

S57

DDS TEST

S58

CALL SCREENING Allows the ISU 128 to screen incoming calls. 0 = Answer any call 1 = Answer only calls from numbers matching those stored in SN0 through SN9.

S59

CHANNEL RATE

SS60

SPID1 LOC

Primary SPID location.

SS61

SPID2 LOC

Secondary SPID string location.

SS62

LDN1 LOC

Primary local directory number string location.

SS63

LDN2 LOC

Secondary local directory number string location.

S70

DTE MODE

Selects asynchronous or synchronous mode on the DTE connector. 0 = Asynchronous 1 = Synchronous

S71

DTE RATE

Selects the DTE connector bit rate. 1 = 300 3 = 1200 6 = 2400 8 = 4800 11= 9600 15= 19200 17= 38400 18= 48000 19= 56000 20= 57600 21= 64000 22= 112020 23= 115200 24= 128000

61202.029L2-1

Sets the available network bandwidth when the ISU 128 is in leased mode. 3 = 64 kbps 5 = 128 kbps

ISU 128 User Manual

113

Page 129

Appendix D. S-Register List

S72

DATA BITS

Selects the number of asynchronous data bits. 0 = 8 bits 1 = 7 bits

S73

DTE PARITY

Selects the number of asynchronous parity bits. 0 = None 1 = Odd 2 = Even

S74

DTE STOP

Selects the number of asynchronous stop bits. 0 = 1 stop bit 1 = 1.5 stop bits 2 = 2 stops bits

S75

DTE FLOW

Selects asynchronous flow control. 0 = None 1 = Hardware flow XON/OFF from DCE controls DTE 2 = XON/OFF from DTE controls DCE 3 = Hardware flow. RTS and CTS flow control. 12= Software flow. XON/OFF controls DTE and DCE.

S76

DTE CLOCK

Selects DTE connector transmit clock timing source. 0 = Internal (ISU 128 supplies timing) 1 = External (DTE supplies timing)

The following are the string locations for stored numbers 0 - 9. SS80 SS81 SS82 SS83 SS84 SS85 SS86 SS87 SS88 SS89

114

SN0 LOC SN1 LOC SN2 LOC SN3 LOC SN4 LOC SN5 LOC SN6 LOC SN7 LOC SN8 LOC SN9 LOC

Stored number 0 string Stored number 1 string Stored number 2 string Stored number 3 string Stored number 4 string Stored number 5 string Stored number 6 string Stored number 7 string Stored number 8 string Stored number 9 string

ISU 128 User Manual

61202.029L2-1

Page 130

Appendix E Connector Pinouts PIN 13

PIN 1 FEMALE

PIN 25

PIN 14

Figure E-1

EIA-232/RS-530 Interface Table E-A

EIA-232 Interface Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Name Shield TD RD RTS CTS DSR SG CD NC NC NC NC NC NC TC NC RC NC NC DTR NC RI NC ETC NC

I/O I/O I O I O O I/O O N/A N/A N/A N/A N/A N/A O N/A O N/A N/A I N/A O N/A I N/A

Description Shield for cable Transmitted Data Received Data Request to Send Clear To Send Data Set Ready Signal Ground Carrier Detect No Connection No Connection No Connection No Connection No Connection No Connection Transmit Clock No Connection Receive Clock No Connection No Connection Data Terminal Ready No Connection Ring Indicator No Connection External Transmit Clock No Connection

I= Input, O= Output, N/A= Not Applicable 61202.029L2-1

ISU 128 User Manual

115