Chapter 11 Troubleshooting When the ISU 128 powers up, it performs an internal self test. This takes about 10 seconds. At the end of the test, the front panel displays Self Test Passed.
IF SELF TEST FAILS If Self Test Passed is not displayed, perform the following procedure to verify if the problem can be fixed locally: 1.
Ensure that the ISU 128 is receiving power and is switched on.
2.
Turn off the ISU 128. While holding down the 0 key, power back on. Continue to press 0 for 15 seconds. This will reset all the internal settings to factory defaults.
3.
If the ISU 128 still does not pass self test, call ADTRAN Technical Support for assistance. See the back of this manual for phone numbers.
IF THE ISU 128 DOES NOT READ READY When the ISU 128 has been set up and connected to an ISDN line but the front panel does not read Ready after a few minutes, use the following troubleshooting procedure: 1.
61202.029L2-1
Cycle power on the ISU 128, leaving it off for a minimum of two seconds. Turn the power on for one minute to ensure the unit does not read Ready.
ISU 128 User Manual
77
Page 93
Chapter 11. Troubleshooting
2.
Disconnect the ISU 128 from the ISDN line. From a functioning voice phone, call the local directory number(s) provided with your line. Calling a good ISDN line with nothing connected usually results in a ring or fast busy tone. If someone answers or a not-in-service intercept is received, there is probably something wrong with the translation of the ISDN line. The phone service provider should be able to help.
3.
If the ISU 128 continues to read Link Down, there is a physical problem with the ISDN phone line (more than likely, a problem with the Layer 1 setup). The problem may be one or more of the following:
• • • • • •
The ISU 128 software setup The ISU 128 hardware The wiring on your premises The telephone service provider's wiring The telephone service provider's hardware The telephone service provider's software setup
To isolate the problem, perform the following procedure: A. Make sure the ISU 128 is configured for dial line service. Check that CONFIG, Netw. options, Dial Line, is selected on the menu. B. Try another piece of functioning ISDN equipment with a U-interface on the ISDN line. C. Talk to your service provider and ensure you have an ISDN Basic Rate U-Interface with 2B1Q line coding (wrong options are an S or T interface or AMI line coding). D. Ensure that your ISDN phone line is connected to the actual telephone line (U-interface) provided by your telephone company. Make sure your ISDN line is not connected though another piece of equipment such as an NT1 in a wiring closet somewhere. E. Make sure nothing else is bridged across the ISDN line pair. F. With a minimum of extra wiring, try connecting to the ISDN line pair at the point where service provider's wiring ends.
78
ISU 128 User Manual
61202.029L2-1
Page 94
Chapter 11. Troubleshooting
G. With the ISU 128 connected to the ISDN line and powered up, talk to your service provider's repair group and inform them that your ISDN basic rate line has a physical layer 1 problem. Ask them to check the ISDN line. Tell them that you have an NT1-like device at the end of the ISDN line. 4.
If the ISU 128 continues to read Getting TEI #1, the ISU 128 is physically connected to your local telephone service provider but is unable to establish logical layer 2. The problem may be one or more of the following:
• • •
The ISU 128 software setup The telephone service provider's software setup Hardware configuration if the ISDN line is extended from the switch
To isolate the problem, use the following procedure: A. Ensure the ISU 128 is set up for the correct switch protocol by selecting CONFIG, Netw. options, Dial Line, Switch protocl. B. Ensure the line quality is satisfactory by checking for near- and far-end block errors (NEBEs and FEBEs). To do this, select Test, NEBE/FEBE. If the counts are non-zero and incrementing, there may be a physical link problem as described under Link Down (Step 3). C. Try another piece of functioning ISDN equipment with a U-interface on the line. D. With the ISU 128 connected to the line and powered up, talk to your service provider's repair group and tell them you have an ISDN basic rate line that appears physically okay but has no terminal endpoint identifier (TEI). Ask them to check the ISDN line translation and ensure that the ISDN line supports dynamic TEI allocation. Tell them that you have an NT1 and terminal adapter device connected to the line.
61202.029L2-1
ISU 128 User Manual
79
Page 95
Chapter 11. Troubleshooting
5.
If the ISU 128 continues to read Register SPID #1, the ISU 128 is physically connected to the local telephone service provider and has established logical layer 2. The ISU 128 is unable to establish layer 3. The problem may be one or more of the following:
• •
The ISU 128 software setup The telephone service provider's software setup
To isolate the problem, use the following procedure: A. Ensure the ISU 128 is set up for the correct switch protocol by selecting CONFIG, Netw. options, Dial line, Switch protocl. B. Ensure the ISDN line is multipoint. C. Make sure that the ISU 128 is set up with the correct SPID and LDN by selecting CONFIG, Netw. options, Dial Line, Terminal ID, SPID/LDN. D. Try another piece of functioning ISDN equipment with a U-interface on the line. E. With the ISU 128 connected to the ISDN line and powered up, talk to your service provider's repair group and tell them you have an ISDN basic rate line that appears physically okay but has no terminal endpoint identifier (TEI). Ask them to check the line translation and ensure that the line supports dynamic TEI allocation. Tell them that you have an NT1 and terminal adapter device connected to the line. 6.
If the ISU 128 continues to read Getting TEI #2, the ISU 128 has completely initialized the first phone number but is unable to establish logical layer 2 for the second phone number. The problem may be one or more of the following:
• •
The ISU 128 software setup The telephone service provider's software setup
To isolate the problem, use the following procedure: A. Ensure the ISDN line is multipoint with two phone numbers.
80
ISU 128 User Manual
61202.029L2-1
Page 96
Chapter 11. Troubleshooting
B. Ensure that the ISU 128 is set up with the correct SPID and LDN by selecting CONFIG, Netw. options, Dial Line, Terminal ID, SPID/LDN. C. Try swapping SPID1 with SPID2 and LDN1 with LDN2. Determine if the problem is the second phone number or the quantity of phone numbers. D. Try another piece of functioning ISDN equipment with a U-interface on the ISDN line. E. With the ISU 128 connected to the ISDN line and powered up, talk to your service provider's repair group and tell them you have an ISDN basic rate line that appears physically okay but has no TEI. Ask them to check the line translation and ensure that the line supports dynamic TEI allocation. Tell them that you have an NT1 and terminal adapter device connected to the line. 7.
If the ISU 128 continues to read Register SPID #2, the ISU 128 has completely initialized the first phone number but is unable to establish logical layer 3 for the second phone number. The problem is in one or more of the following places:
• •
The ISU 128 software setup The telephone service provider's software setup
To isolate the problem, use the following procedure: A. Ensure the ISDN line is multipoint with two phone numbers. B. Ensure that the ISU 128 is set up with the correct SPID and LDN by selecting CONFIG, Netw. options, Dial Line, Terminal ID, SPID/LDN. C. Try swapping SPID1 with SPID2 and LDN1 with LDN2. Determine if the problem is the second phone number or the quantity of phone numbers. D. Try another piece of functioning ISDN equipment with a U-interface on the line.
61202.029L2-1
ISU 128 User Manual
81
Page 97
Chapter 11. Troubleshooting
E. With the ISU 128 connected to the line and powered up, talk to your service provider's repair group and tell them you have an ISDN basic rate line that appears physically okay but has no terminal endpoint identifier (TEI). Ask them to check the line translation and ensure that the line supports dynamic TEI allocation. Tell them that you have an NT1 and terminal adapter device connected to the line.
82
ISU 128 User Manual
61202.029L2-1
Page 98
Chapter 12 Specifications SPECIFICATIONS AND FEATURES This section describes the standard specifications and features incorporated in the ISU 128. Network Interface • RJ-45 for ISDN Basic Rate U-Interface, and Leased 2B1Q service DTE Interface • RS-530 • V.35 • EIA-232 Dialing Selections • In-band DTE dialing: V.25 or AT commands • Manual or automatic stored number dialing, DTR assertion • Dial interface: RS-366 • Front panel manual dialing Data Rates (Network) 64 kbps (one B channel), 128 kbps (two B channels) Data Rates (DTE) • 300 bps to 115.2 kbps asynchronous • 2400 bps to 128 kbps synchronous
61202.029L2-1
ISU 128 User Manual
83
Page 99
Chapter 12. Specifications
Rate Adaption • T-Link • CCITT V.120 • CCITT V.110 • SAP • DSU 57.6 Async • BONDING mode 1 • V.34 (optional) • PPP • MP Interoperability • BONDING Inverse Multiplexers • Switched 56 DSUs • ISDN TAs • V.34 modems (optional) Switch Compatibility • AT&T 5ESS • NTI DMS-100 • National ISDN-1 • NEC B Channel Aggregation • BONDING Mode 1 • MP Display • Two-line by 16 character LCD • LED indicators RS Request to Send. Indicates the DTE is ready to transmit. CS Clear to Send. Indicates the ISU 128 is ready to transmit. TD Transmit Data. On when the DTE is transmitting to the ISU 128. RD Receive Data. On when the ISU 128 is receiving data from the far end. CD Carrier Detect. On when the ISU 128 is connected to a remote unit.